Terracotta clay baguette terracotta louvre for exterior cladding

Share on (62111052222):


Price:

Quantity:


Product Overview

Description


Product Picture

Paneltek

Terracotta clay baguette terracotta louvre for exterior cladding

 

 

   Product Name   Terracotta Louver/Baguette 
   Length   300-1500mm
   Thickness   8mm /customized
   Width   50*50 60*100 60*150mm
   Color   White/Red/Gray/Yellow/Blue/Green...
   Surface   Custom Surface
   Application   Curtain Wall, Decoration Wall Louver
   OEM&ODM   Yes

 

 

Product Details

  Performance 

  Indicators

   Technical Performance of Terracotta Products  GB  EN14411

 306*F18 WHITE 

Terracotta Panels

 306*F18 GRAY
Terracotta Panels
 310*F30 YELLOW
Terracotta Panels
 Water Absorption 1.1% 1.4% 2.34%

 (I)3%-6%

(II)6%-10%

 (I)3%-6%

(II)6%-10%

 Dry Weight 31kg/m2 31kg/m2 41kg/m2 / /
 Frost Resistance

 No damage after

100
freeze-thaw cycles

 No damage after

100
freeze-thaw cycles

 No damage after

100
freeze-thaw

cycles

 Testedvalue

of the report

 Tested value

of the report

 Damage Strength 4966N 4779N 8722N  ≥750N  ≥750N
 Rupture Modulus Avg: 97MPa
Min: 86MPa
 Avg: 59.36MPa
Min: ≥50MPa
 Avg: 92.43MPa
Min: 80MPa
 Avg: ≥9MPa
Single
Value:≥ 8MPa
 Avg: ≥9MPa
Single
Value:≥ 8MPa
 Poisson's Ratio 0.16 0.16 0.16  /  /

 Modulus of

Elasticity

 44GPa 34GPa 34GPa  /  /
 Fire Resistance Level A1 Level A1 Level A1  /  /
 Resistance to
Acid&Alkali
 Level ULA Level ULA Level ULA Tested value of the report Tested value of the report
 Radioactivity Class-A decorative
material
 Class-A decorative
material
 Class-A decorative
material
  /  /
 Earthquake
Resistance
 Over 10 degrees Over 10 degrees Over 10 degrees  /  /
 Test under Simulated
Wind Load
 No breakage under  11kPa No breakage under  119kPa No breakage under  11kPa  /  /
 Sound Insulation Noise reduction by over 9dB Noise reduction by over 9dB Noise reduction by over 9dB  /  /
 Heat Conductivity 0.31w/m.k 0.31w/m.k 0.41w/m.k  /  /
Thermal Shock
Resistance
No cracksNo cracksNo cracksTested value of the reportTested value of the report
Fouling ResistanceLevel 2Level 2Level 2Level 2 at leastLevel 2 at least
Impact Resistance0.780.780.78Tested value of the reportTested value of the report
Linear Coefficient of
Thermal Expansion
5.2×10-6 °C -15.2×10-6 °C -15.2×10-6 °C -1Tested value of the reportTested value of the report

Packaging & Shipping

Paneltek_Detail-Page_13

Related Product

Company Information

Paneltek_Detail-Page_17

Paneltek_Detail-Page_19

Paneltek_Detail-Page_20

 