Bante900P Portable Multiparameter Water Q - Analyzers">

TPS Bante900P Portable Multiparameter Water Quality Meter for pH, ORP, ion, conductivity, TDS, salinity, resistivity, DO Bante900P Portable Multiparameter Water Q

Share on (62133547718):


Price:RUB 51,657.34

Quantity:


Product Overview

Description

Bante900P Portable Multiparameter Water Quality Meter

Multiparameter water quality meter contains 8 measurement modes, the meter is suitable for measuring the pH, ORP, ion, conductivity, TDS, salinity, resistivity and dissolved oxygen.

pH Mode:
• Multiparameter portable water quality meter is equipped with a backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer group (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode diagnosis with pH slope and offset display.

ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes provide the reliable ORP measurements.

TPS-Bante900P 5.jpg

Ion Mode:
• 2 to 5 points calibration, including the 8 concentration points can be selected.
• Automatically recognizes the ion selective electrode, does not need to specify type of ion.
• Direct ion concentration readout simplifies the measurement process.
• Selectable concentration units, including the ppm, mg/L and mol/L.

Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration, automatically recognizes the conductivity standard solutions.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear/
  pure water compensations, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Selectable the salinity and barometric pressure compensation coefficients. 

TPS-Bante900P 6.jpg

Other Features:
• Automatic Temperature Compensation ensures accurate readings over the entire range.
• Calibration Due Alarm prompts user to calibrate the meter regularly.
• Stability indicator shows when a measurement is recognized as stable.
• Auto-Read feature senses and locks the measurement endpoint.
• Battery indicator shows the remaining battery capacity.
• Auto-Power Off effectively conserves battery life.
• Calibration report provides the details for checking the electrode performance.
• Setup menu allows setting the 15 parameters, including the number of calibration points,
  stability criteria, temperature unit, date and time, etc.
• Reset feature automatically resumes all settings back to factory default options.
• Expanded memory stores and recalls up to 500 data sets.
• Stored readings can be transferred into the computer by USB communication interface.
• Multi-mode power scheme (batteries, power adapter and USB port) ensures that use the
  meter smoothly.

 

Model

Bante900P

   pH

 

   Range

-2.000~20.000pH

   Accuracy

±0.002pH

   Resolution

0.1, 0.01, 0.001pH, selectable

   Calibration Points

1 to 5 points

   pH Buffer Options

USA, NIST, DIN or Custom

   mV

 

   Range

±1999.9mV

   Accuracy

±0.2mV

   Resolution

0.1, 1mV, selectable

   Calibration Points

1 point

   Measurement Modes

Relative or Absolute mV

   Ion

 

   Range

0.001~19999 (Deponding on the range of ISE)

   Accuracy

±0.5% F.S (Monovalent), ±1% F.S (Divalent)

   Resolution

0.001, 0.01, 0.1, 1

   Calibration Points

2 to 5 points (0.001, 0.01, 0.1, 1, 10,  100, 1000, 10000)

   Measurement Units

ppm, mg/L, mol/L, mmol/L

   Conductivity

 

   Range

0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm

   Accuracy

±0.5% F.S

   Resolution

0.001, 0.01, 0.1, 1

   Calibration Points

1 to 5 points

   Calibration Solutions

10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm

   Temperature Coefficient

0.0~10.0%/°C

   Compensation Modes

Linear or Pure water

   Cell Constant

K=0.1, 1, 10 or Custom

   Reference Temperature

20°C or 25°C

   TDS

 

   Range

0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt)

   Accuracy

±1% F.S

   Resolution

0.01, 0.1, 1

   TDS Factor

0.1~1.0 (Default 0.5)

   Salinity

 

   Range

0.00~80.00ppt, 0.00~42.00psu

   Accuracy

±1% F.S

   Resolution

0.01

   Measurement Modes

Practical salinity (psu) or Natural seawater (ppt)

   Resistivity

 

   Range

0.00~20.00MΩ

   Accuracy

±1% F.S

   Resolution

0.01, 0.1, 1

   Dissolved Oxygen

 

   DO Range

0.00~20.00mg/L

   Accuracy

±0.2mg/L

   Resolution

0.1, 0.01mg/L, selectable

   % Saturation of Oxygen

0.0~200.0%

   Accuracy

±2.0%

   Resolution

0.1, 1%

   Calibration Points

1 or 2 points

   Pressure Correction

60.0~112.5kPa, 450~850mmHg

   Salinity Correction

0~50g/L

   Temperature

 

   Range

0~105°C, 32~221°F

   Accuracy

±0.5°C

   Resolution

0.1°C, 0.1°F

   Calibration Points

1 point

   Calibration Range

Measured value ±10°C

   General

 

   Temperature Compensation

0~100°C, 32~212°F, Manual or Automatic

   Data Hold

Manual or Auto-Endpoint

   Stability Criteria

Low or High

   Calibration Due Alarm

1 to 31 days or Off

   Power Off

Manual or Automatic (10, 20, 30 minutes)

   Reset Function

Yes

   Memory

Stores up to 500 data sets

   Output

USB communication interface

   Connector

BNC, 6-pin mini plug

   Display

LCD

   Power

3×1.5V AA batteries or DC5V power adapter

   Battery Life

Approximately 150 hours (Turn off the backlit)

   Dimensions

170(L)×85(W)×30(H)mm

   Weight

300g

 

optional accessories

Items Description
P11 pH Electrode Suitable for the general applications
P12 pH Electrode Suitable for the sample in the test tube
P13 pH Electrode Suitable for the micro-volume samples
P15 pH Electrode Suitable for the low conductivity samples
P16 pH Electrode Suitable for the Tris buffers
P18 pH Electrode Suitable for the slurries and soils
P19 pH Electrode Suitable for the semisolids
P21 pH Electrode Suitable for the colloids
P22 pH Electrode Suitable for the high temperature samples
501 ORP Electrode Suitable for the sample with strong redox potential
502 ORP Electrode Suitable for the sample with weak redox potential
Na-US Sodium Electrode Range: 0.1~23000ppm
CL-US Chloride Electrode Range: 1.8~35500ppm
F-US Fluoride Electrode Range: 0.02ppm~Saturation
Ca-US Calcium Electrode Range: 0.02~4000ppm
NO3-US Nitrate Electrode Range: 0.4~62000ppm
Br-US Bromide Electrode Range: 0.4~79900ppm
NH4-US Ammonium Electrode Range: 0.1~18000ppm
Cn-US Cyanide Electrode Range: 0.2~260ppm
Cd-US Cadmium Electrode Range: 0.01~11200ppm
Cu-US Copper Electrode Range: 0.006~6400ppm
I-US Iodide Electrode Range: 0.06~127000ppm
Pb-US Lead Electrode Range: 0.2~20700ppm
Ag-US Silver Electrode Range: 0.01~107900ppm
K-US Potassium Electrode Range: 0.04~39000ppm
S-US Sulphide Electrode Range: 0.003~32100ppm
NH3-US Ammonia Electrode Range: 0.02~17000ppm
CON-0.1 Conductivity Electrode Suitable for the pure water
CON-1 Conductivity Electrode Suitable for the general applications
CON-10 Conductivity Electrode Suitable for the high conductivity liquids
DO100 Dissolved Oxygen Probe Suitable for DO and % saturation measurements
DO Membrane Cap Suitable for DO100 probe
DO Electrolyte Solution Suitable for DO100 probe
TP-10K Temperature Probe Special-purpose temperature sensor
pH Buffer Solutions 480mL/bottle
Conductivity Standard Solutions 480mL/bottle
Ion Standard Solutions 480mL/bottle
Ionic Strength Adjuster 480mL/bottle

 

0.1975 s.