•Dry type, magnet drive, clean dial to guarantee it legible reading, resistance to magnetic interference.
•Available with non-return valve, inlet strainer and pulse output on request.
•Technical data conform to International Standard ISO4064 Class B.
Working condition:
temperature:≤40℃
Pressure:≤1Mpa
Maximum Permissible Error:
Qmin→Qt (ex Qt)=±5%;
Qt→Qs (both included)=±2% or ±3%(hot water)
Qmin=Min Flow, Qt=Transition Flow, Qs= Max Flow.
Parameters:
DN | Flow range | Q4 | Q3 | Q2 | Q1 | Starting flow | Min reading | Max reading |
mm | Q3/Q1 | m3/h | m3/h | l/h | l/h | l/h | m3 | m3 |
LXS-15E | 80/160 | 3.125 | 2.5 | 50/25 | 31.25/15.625 | 6/5 | 0.00005 | 99999 |
LXS-20E | 80/160 | 5 | 4 | 80/40 | 50/25 | 10/6 | 0.00005 | 99999 |
LXS-25E | 80/160 | 7.875 | 6.3 | 126/63 | 78.75/39.375 | 12/8 | 0.00005 | 99999 |
LXS-32E | 80/160 | 12.5 | 10 | 200/100 | 125/62.5 | 14/10 | 0.00005 | 99999 |
LXS-40E | 80/160 | 20 | 16 | 320/160 | 200/100 | 40/35 | 0.00005 | 99999 |
Dimension and weight:
DN | Length | Width | Height | Connecting thread | Weight |
mm | mm | mm | mm | D | kg |
15 | 165 | 98 | 104 | G3/4B | 1.5 |
20 | 195 | 98 | 106 | G1B | 1.7 |
25 | 225 | 104 | 120 | G1-3/4B | 2.6 |
32 | 230 | 104 | 120 | G1-3/2B | 2.8 |
40 | 245 | 125 | 155 | G2B | 5.4 |
Specifications:
1. Simple structure.
2. Convinient manufacture and maintenance, low cost.
3. Durable and low requirements to water quality.
4. Error is easy to adjust.
5. Flow rate is relatively large.
6. Sensitivity is good.
7. Straight pipeline requirement is low.
Difference between dry dial water meter and wet dial water meter
The biggest difference between dry water meter and wet water meter is the measurement mechanism. The impeller is separated from the central gear, and the upper end of the impeller is composed of magnetic elements "magnetic ring or columnar steel" and the magnetic components at the lower end of the sun gear. When the impeller is rotated, the magnetic element at the upper end of the impeller is sucked or repelled by the magnetic element at the lower end of the sun gear, and the central gear is driven to rotate synchronously, and the water flow through the water meter is recorded by the center drive counter. As mentioned above, the measuring mechanism of the dry water meter is different from that of the wet water meter.
Workshop show:
ISO 4064 class b bronze drinking water meter installation price
ISO 4064 class b bronze drinking water meter installation price
ISO 4064 class b bronze drinking water meter installation price
1.Are you a trade company or a manufacturer?
Kaifeng Shengda Meter Co., Ltd has been a professional manufacturer for over 20 years to undertake design and processing of all types of flow meter to provide production service and technical support for customers.
2.What to do if I have any other specifications for the current?
If you have any different requirements,just contact us and we will meet you.
3.If I need a sample for pretest, do you sale sample for this inquiry?
Yes, we can sale sample for pretest. If you need this service, please contact us and we will give you a quotation.
4.Can you produce the products according to my own drawings?
Yes, we can do OEM according to your requirement.
Please contact us for the WHOLE CATALOGUE, our technical engineers are waiting for solving your problems now!! Action now!!