Universal Testing Machine Electronic Galvanized Chrome Coating Thickness Gauge
These gauges can be used for non-destructive coating thickness measurement of non-magnetic coatings, e.g. paint, enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous metals.
Features:
· 128*128 dot matrix LCD display, standard menu operations
· Two measure modes: single and continuous
· Two group modes: direct (DIR) and general (GEN), readings will be lost when power off in direct mode, and not be lost in general mode. 80 readings can be stored for each group
· Zero point calibration and multi-point calibration (up to 4 points) for each group
· User can recall, delete specified readings, or delete group readings
· Statistics display: mean, minimum, maximum and standard deviation
· Three probe modes: auto, magnetic and eddy current
· User can set a high or low alarm limit for each group
· Power off automatically
· USB interface to data transmission
· Low battery and error indication
Specifications:
Model |
EC-770S |
EC-770SF |
EC-770SN |
Probe |
F-Probe & N-Probe |
F-Probe |
N-Probe |
Measuring Principle |
Magnetic induction & Eddy Currents |
Magnetic induction |
Eddy Currents |
Measuring Range |
0 to 2000 um |
||
Accuracy |
± (2%+1 um) |
||
Resolution |
0~99.9um(0.1um), others(1um) |
||
Calibration |
One point to four points calibration, zero point calibration |
||
Data Group |
One direct group(readings not be stored to memory) |
||
Four general groups (readings will be stored automatically) |
|||
NOTE: each group have individual statistics, alarm limit settings, and calibration |
|||
Statistics |
No. of readings, mean, minimum, maximum and standard deviation |
||
Units |
um, mm, mil |
||
Alarm |
User can set the high/low alarm limit; Alarm icon displayed on LCD when over the limit |
||
Minimum Curvature Radius Convex |
1.5 mm |
||
Minimum Curvature Radius Concave |
25 mm |
||
Minimum Measuring Area |
Diameter 6 mm |
||
Minimum Thickness Of Substrate |
F-probe: 0.5 mm(0.02");N-probe: 0.3 mm(0.012") |
||
Computer Interface |
Download data via USB |
||
Power Supply |
Two 1.5 V AAA battery |
||
Operation Environment |
Temperature: -10 to 50℃ |
||
Storage Environment |
Temperature: -10 to 60°C(-4 to 158°F) |
||
Standard Certification |
CE, ROHS, ISO 2178, 2360, GB/T 4956-2003, 4957-2003 |
||
Dimensions |
113mmX53mmX24mm/80g/ABS |
||
Readings memory |
2000 readings |
1. OEM Manufacturing
2. ODM service
3. Small order/ Prompt delivery
4. We will reply to you for your inquiry within 24 hours.
1. Is the measuring error large?
• Enter the menu interface, clear the calibration data; shut down to restore the factory configuration steps; do zero calibration after booting, (Note: you need to do zero calibration on the customer's own substrate)
2. Does the measurement screen display overflow?
• The coating thickness exceeds the measurement range.
• There is an error and zero calibration is required on the substrate.
• Probe fault
3. Measurement no response?
• Check if the battery has power.
• The probe has a fault.
• Whether the measured material meets the measurement principle.
4. Does the measurement show a negative number?
• It is judged according to the customer's materials whether the machine accuracy is applicable.
• The calibration did not do well and needs to be recalibrated.
5. During the measurement process, is it sometimes display F, sometimes display N?
• The automatic mode undistinguishable the type of material and it requires manual switching of the measurement principle.
6. How to do calibration?
• Please refer to the zero calibration, point calibration step.
7. Long press "ZERO" does not respond?
• You need to restore the factory settings and then operate.
8. It can measurement but there is no reading, why?
• Confirm whether the mode is in continuous measurement mode
• Check if the beep is broken