Professional Emergency Auto CPR machine, First Aid Auto CPR Device MSLHS02 (62288618465)

Share on:


Price:
Price in USD:Details

Quantity:


Product Overview

Description


001.jpg

Product Description

01.jpg 

Professional Emergency Auto CPR machine, First Aid Auto CPR Device MSLHS02

002.jpg

Portable First Aid Auto-CPR Device MSLHS02 for hospital emergency room resuscitator

Digital multi-function CPR based on DCCP the multi-function portable CPR machine system

.jpg

Leader of standardized perfectly performed CPR

2018 American Heart Association includes:

Chest compressions depth < 6 cm;

Chest compressions frequency < 120 times/min;

Thoracic fully rebound after each pressing;

Reduce the interruption of chest compressions.

 

Nbc design: waterproof, UNBreak, Quakeproof

Digital

Touch-tone;

Breathing and circulation support mode switch freely;

30:2 pattern will repeat continuously.

1B.jpg

 

Auto-CPR Device MSLHS02 parameter

1,Pressing depth:30 ~65mm adjustable,one type:5mm,error:±2 mm;

2,Pressing release rate:1:1 ;

3,pressure relief valve:0.65Mpa;error:±0.12Mpa;

4,Pressure of gas road is no less than 1Mpa;

5, Ventilation quanity:500ML no adjust,error:±10%;

working pressure:≤816.4N ;

6,input power(DC):≤17W; AC:≤54W;

7,Press the ventilation ratio:30:2 continuously adjustable;,error:±1 time;

8,Pressing frequency: 100times/ min,110times/ min,120times/ min error:±1 time;

9,The fastness of fastening band fastness is not less than 100N;

10,The thickness range of patients was 155 to 305MM.

11,The pressure is not enough to alarm, the pressure depth is reduced automatically, and the manual

recovery after air pressure recovery must be deep.

12,Electricity, according to the low voltage alarm, start the suspended function;

13,Default mode:Press the ventilation ratio: 30: 2,press depth 30mm,press frequence 100 pcs/min

Ventilation quanity 500ML

14,Safety requirements refer to medical electrical appliances safety standard GB 9706.1-2007,

electromagnetic compatibility standard YY05052012;

15,Earthquake Resistance

16,drop resistance

17,The enclosure protection level is IP55 (dustproof and water spray);

18,noise≤70dB ;

19,Working environment : a)Temperature:-20℃~55℃;

b)Relative temperatur:10%~90%; 

c)Atmospheric pressure:500hPa~1060hPa.

 

 

Accurate:

Compression depth: error < 2mm

Compressions frequency: error = 0
 
C type spiral arms open vertical pressure
Fuselage rotate 360 degrees, it's convenient to cooperate to produce another rescue measures.

Control system

Security state Default
Air access equipped with fast plug-in
Quick start in 2 seconds

Platforms(system function)

Security
Convenient
Simpleness

Detail Image

 02.png

 

03.png

 

06.png

 

QQ20170727110900.jpg

 

QQ20170727110855.jpg

 

Certifications

10.jpg 

Company introduction

08.jpg09.jpg12.jpg 


62288618465