RDO-206A integrated on-line fluorescence dissolved oxygen sensor is designed and fabricated based on the quenching principle of excited fluorescence by specific substances in physics. The blue light emitted by the light emitting diode (LED) irradiates on the fluorescent substance on the inner surface of the fluorescent cap, and the fluorescent material on the inner surface is excited and emits red light. by detecting the phase difference between the red light and the blue light and comparing it with the internal calibration value, the concentration of oxygen molecules is calculated, and the final value is automatically compensated by temperature.
• No electrolyte is required and will not be polarized.
• No oxygen consumption, not affected by flow rate.
• Built-in temperature sensor, automatic temperature compensation.
• Free from interference by chemicals such as sulfides
• Small drift, rapid reaction, more accurate measurement.
• Maintenance-free, long service cycle, lower cost of use.
• Simple replacement of fluorescent cap.
Model | RDO-206A |
Measuring principle | Fluorescence method |
Range ability | 0~20mg/L (0 ≤ 200% saturation) |
Resolution ratio | 0.01mg/L,0.1℃ |
Precision | ±2%F.S.,±0.5℃ |
Temperature compensation | Automatic temperature compensation(Pt1000) |
Output mode | RS-485 bus, Modbus-RTU protocol |
Working conditions | 0~45℃,<0.2MPa |
Storage temperature | -5~65℃ |
Installation mode | Immersion mounting |
Cable length | 5 meters, other lengths customizable |
Power dissipation | <0.5W |
Source | 12~24VDC ±10% |
levels of protection | IP68 |
Calibration | Two-point calibration |
Fluorescent cap life | Guaranteed use for one year (under normal use) |
Sensor shell material | POM and 316L stainless steel |
Note: The temperature induction part should be immersed below the liquid level to avoid colliding with the surface of the film head. The attachment of sediment should be avoided in the part of membrane head.
Suitable for environmental monitoring,environment analysis,modern agriculture,sewage treatment,smart city,food and medical,water treatment,tap water otheprocess and fields.
This product includes:
Sensor*1
User manual*1
Certificate* 1
Chemins provides the after-sale service within one year from the date of the sales, but does not include the damage caused by improper using. If you need repair or adjustment, please send it back, and the freight should be paid. When sending back, determine the good packaging to avoid transit damage, and the company will be free maintenance device damage.