По ограничению на использование опасных материалов в производстве Сертификация Чистая синусоида Инвертор 3000w 12v 24v Инвертор постоянного тока в переменный 110v 220v Инвертор солнечной энергии

Share on (62349307756):


Price:212,00 $ - 244,86 $

Quantity:


Product Overview

Description



Rohs Certification pure sine wave inverter 3000w 12v 24v dc to ac 110v 220v solar inverter










Rohs Certification pure sine wave inverter 3000w 12v 24v dc to ac 110v 220v solar inverter
MODEL
FS3000-112
FS3000-124
FS3000-148
FS3000-212
FS3000-224
FS3000-248
Output
AC Voltage
100/110/120VAC
220/230/240VAC
Rated Power
3000W
Surge Power
Load 120~150%(3min.);6000W(3sec;resistive)
Waveform
Pure Sine Wave(THD<3%)
Frequency
50/60Hz ±0.05%
AC Regulation
±5%
±10%
Power Factor Allowed
COSθ-90°~COSθ+90°
Standard Receptacles
USA/British/Franch/Schuko /UK/Australia/Universal etc. optional
LED Indicator
Green for power on, red for faulty status
USB port
5V 2.1A
5V 2.1A
------
5V2.1A
5V 2.1A
------
LCD display
voltage, power, protection status ( optional)
Remote control function
default
Remote controller
CR80/CRD80 optional
Input
No Load Current Draw
≤1. 2A
≤0.80A
≤0.70A
≤1.2A
≤0.80A
≤0.70A
DC Voltage
12VDC
24VDC
48VDC
12VDC
24VDC
48VDC
Voltage Range
10.5~15VDC
21~30VDC
42~60VDC
10.5~15VDC
21~30VDC
42~60VDC
Efficiency(Typ.)
89%~93%
Fuse
40A×12
20A×12
10A×12
40A×12
20A×12
10A×12
Remote Control
Function (optional)
Protection
BAT. Low Alarm
10.5±0.5VDC
21±1.0VDC
42±2.0VDC
10.5±0.5VDC
21±1.0VDC
42±2.0VDC
BAT. Low Shutdown
10±0.5VDC
20±1.0VDC
40±2.0VDC
10±0.5VDC
20±1.0VDC
40±2.0VDC
Over Load
Shut down output voltage , restart to recover
Over Voltage
15.5±0.5VDC
31±1.0VDC
62±2.0VDC
15.5±0.5VDC
31±1.0VDC
62±2.0VDC
Over Temperature
Shut down output voltage , recover automatically after temperature goes down
Output Short
Shut down output voltage , restart to recover
DC Input Reverse Polarity
By fuse
Earth Fault
Shut off o/p when the load has electrical leakage
Soft Start
Yes, 3-5 Seconds
Environment
Working Temp.
0~+50℃
Working Humidity
20~90%RH non-condensing
Storage Temp.&Humidity
-30~+70℃,10~95%RH
Safety & EMC
Safety Standards
Certified UL 458(only for "GFCI" receptacles)
Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013.
Isolation Resistance
I/P-O/P:100M Ohms/500VDC
EMI Conduction &
Radiation
Certified FCC class A
Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3;
EMS Immunity
------
Certified IEC61000-4-3, IEC61000-4-6
E-MARK
------
Certified ECE RIO.05:2014
Others
Dimension(L×W×H)
442.2×261.3×112.7mm
Packing
8kg;2pcs/17kg/0.07m³
Cooling
Load control fan or by thermal control fan
Application
Home and Office appliances,Portable Power Equipment,Vehicle,Yacht and Off-Gid Solar
power systems…etc.












0.211 s.