High Quality Wet Dispersion 0.01um 1250um Laser Particle Size Analyzer Price

Share on (62379780687):


Price:

Quantity:


Product Overview

Description


Product Description
High Quality Wet Dispersion 0.01μm -1250μm Laser Particle Size Analyzer Price

Description:
Main performance characteristics of NKT6100-A laser particle size analyzer: ★ Advanced optical path design: NKT6100-A adopts
convergent Fourier transform test technology to ensure maximum range in the shortest focal length, effectively improving the
resolution of the instrument; The unique high-density detection unit enables the 6100-A to have super-strong small particle
testing capability, while the high-density detection unit enables the NKT6100-A to have super-strong full-scale seamless testing
capability. ★ dustproof and shockproof design: the whole instrument is designed in a sealed way, which greatly improves the
service life of internal components. The unique suspension structure can effectively avoid the interference of external vibration
on the instrument, making the result test more stable and reliable. ★ Automatic centering: The technology of combining mechanical
center and optical center is adopted exclusively, and the automatic adjustment and positioning of optical path are more accurate,
reaching micron level; At the same time, the speed of light path adjustment is faster and can be completed within 15 seconds. The
self-developed automatic centering system consists of a stepping motor, a precision guide rail, a precision controller and a
software system, with a minimum step distance of 0.2 micron, which ensures that the laser beam focus always passes through the
center point of the detector and improves the accuracy of the test result and the repeatability of the test. The automatic
centering system is the standard configuration for all Nike laser particle sizers. ★ Intelligent full-automatic operation mode:
software realizes one-key operation, automatic water intake, automatic sample introduction, automatic testing and automatic
cleaning. The whole testing process realizes one-key full-automatic operation, which is convenient and quick to use. ★ Unique
micro circulation system: The whole dispersion circulation system has been optimized and tested circularly when the dispersion
medium is more than 120ml, thus truly achieving the micro circulation test. All joints are designed for quick insertion and quick
screwing, and all pipes can be replaced in a short time. The optimized design ensures no waste residue at night after drainage and
ensures the accuracy of the next test result. ★ Ultra-wide measuring range: NKT6100-A measuring range reaches 0.01μ m ~ 1250μ m.
Specification model
NKT6100-A
Implementation standard
ISO 13320-1:1999;GB/T19077.1-2008
Test range
0.01μm -1250μm
Number of detector channels
90
Accuracy error
< 0.5% (D50 value of national standard sample)
repeatability error
< 0.5% (D50 value of national standard sample)
No bubble discharge
With bubble-free design, data without bubble interference is more accurate.
Misoperation protection
The instrument has self-protection function for misoperation, and the instrument does not respond to misoperation.
Laser parameters
Imported fiber output high power laser λ= 635nm, p>5mW
Optical path calibration
Automatic optical path calibration
Dispersion method
ultrasonic
Frequency: f=40KHz, power: p=100W, time: freely adjustable; With ultrasonic anti-dry burning
Circulation and stirring
Integrated design of circulation and stirring with adjustable rotating speed of 100-33950rpm.
Circulation flow
Rated flow: 0-30L/min Adjustable rated power: 25W
Sample cell
Self-designed boiling type sample cell has better dispersion effect, and the capacity: 190-600mL can be tested normally.
Microinjection
The instrument can be equipped with micro full-automatic testing device, and 10 ml can be used for cyclic testing (optional)
operator schema
Computer operation
Test speed
< 1min/ time (excluding sample dispersion time)
Volume
980mm*410mm*450mm
Weight
35Kg
Company Profile
Recommend Products
Certifications
Packing&Shipping
FAQ
Purchase laser particle size analyzer need know points:
1) What materials need test?
If suspension/emulsion, must choose liquid dispersion particle size analyzer, and some materials are also reacted with water, so
need liquid dispersion particle size analyzer also.
Generally, cement, metal powders and pharamcy materials need dry dispersion model particle size analzyer.
2) What size range need test?
By now, Based on MIE scattering, laser particle size analyzer can test the particle range is 0.01um-2000um.
If materials range is not so wide, for example, 10um-20um, smaller range of particle size distributon choose closer range model
will be preciser, no need to buy large range model.
3) What is dispersion media?
For liquid model, in order that sample can disperse well and circualte in the laser particle size analyzer, generally we need use
water, alochol or organic solvent as dispersion media.
For dry dispersion model, just use compressed air as dispersion media.
In the current market, Dry laser particle size analyzer cost is higher than liquid dispersion models, so if can test well, liquid
model is better.
More questions, please contact us, we will offer you the best suitable laser particle size analyzer for you!

0.4414 s.