Share on (62486487100):
Product Description
Alien Capsule Non-surgical Spinal Traction System(Cervical FJZ-6502) is a new generation of modernized physical rehabilitation equipment, which is developed by Zhengzhou Feilong Medical Equipment Co., Ltd .The equipment is non-surgical, painless. accurate positioning. It cures the disc vertebra nutritionally with constant high negative pressure. It supplies a new therapy for many patients with cervical spondylosis.

Design Inspiration
NASA recorded the response of pur spine to a weightless environment for the first time, during a test flight of Space Lab 4 and Apollo.
In the state of weightlessness, it can effectively eliminate the resistance of the paravertrbral muscles, and it can easily open the intervertebral disc, so that the nutrients in the body can quickly enter the intervertebral space, and the height of the intervertebral disc is significantly increased.
Indication
1. Cervical disc herniation
2. Cervical muscle strain
3. Cervical spondylosis
4. Sympathetic cervical spondylosis
5. Vertebral artery type cervical spondylosis.

Technical Parameters:
Voltage | AC220V±22V |
Frequency | 50Hz±1Hz |
Rated input power | 500VA |
Environmental temperature | +5℃ ~ +40℃ |
Dimension | Length:3200mm* Width1030mm* Height:2000mm |
Bed Translation | 0-150mm |
Traction range | 0-137N |
Bed Safe Bearing Load | 1764N |
Bed overturn angle | 0~68°,tolerance range:±2° |
Traction angle | 0°, 2°, 4°,8°,13°,17°,tolerance range:±2° |
UPS power | Online charge,frequency: 50-60HZ, voltage: 220V, power:2KVA Power-on time no less than 10 minutes after power loss |
Computer Hardware configuration | Touch screen HD industrial computer |
Advantages:
1, Imitation weightless (The system on the basis of Imitation weightless )
2, Non-surgery (Patients make treatment no surgery)
3, No pain(There is no pain when make treatment)
4, High negative pressure(The system produce high negative pressure in the disc)
5, Accurate positioning(System make accurate treatment on the basis of the diseased region(S1-S5) )
6, Deep nourishing(The Oxygen,Water and nutriment penetrate in the disc and nourish the disc )
FQA:
Q1. Size of Cervical Positioning Cycle System
A: 3.6*1.28*2.36M
Q2. Application of Cervical Positioning Cycle System
A:
Q3: Parts Composition

1. Controlling body 2. Controller 3. Base 4. Treatment angle controller
5. Head fixing device 6.Treatment bed 7.Pedals 8.Lighting equipment
Q4. Warranty
A: 1 YEAR for main body.
Q5. Life time
A: 8 years
Q6. OEM Service
A: Available
Q7: Visiting of factory
A: Always welcomed
New products from manufacturers at wholesale prices