Home Power Inverter 8KW 10KW 12KW Pure Sine Wave Off Grid
Model | 8048E/8096E | 10048E/10096E | 12048E/12096E | |||
Rate Power | 8000W | 10000W | 12000W | |||
Input |
|
|
| |||
Voltage | 220V/230V/240Vac | |||||
Selectable Volt Range | Wide:170~265Vac(for home appliance) Narrow:195~265Vac(for personal computer) | |||||
Frequency Range | 40~70Hz | |||||
Output |
|
|
| |||
AC Volt Regulation | Vac(+/- 10V) | |||||
Surge Power | 24KVA | 30KVA | 36KVA | |||
Efficiency(Peak) | 90% | |||||
Transfer time | <20ms | |||||
Wave Form | Pure sine wave | |||||
Battery |
|
|
| |||
Battery Voltage | 48Vdc | 96Vdc | 48Vdc | 96Vdc | 48Vdc | 96Vdc |
Charging Current | 70A | 35A | 75A | 40A | 75A | 50A |
Fast Charge Voltage | 57.2V | 114.4V | 57.2V | 114.4V | 57.2V | 114.4V |
Float Charge Voltage | 54.8V | 109.6V | 54.8V | 109.6V | 54.8V | 109.6V |
Overcharge protection | 66V | 132V | 66V | 132V | 66V | 132V |
Battery low volt alarm | 42V | 84V | 42V | 84V | 42V | 84V |
Battery low volt shutdown | 40V | 80V | 40V | 80V | 40V | 80V |
Protections | Over-charge,Over-tem,Over battery,Over load,short-circuit | |||||
Operation environment temp | 55℃ | |||||
Cooling | Intelligent fan | |||||
Display | Colar LCD | |||||
Specification setting | By LCD or Position Machine: Charging Current,Battery type,Input voltage,Output frequency,Wide and narrow of ac input voltage,Power-saver model,AC priority or battery priority; | |||||
Physical |
|
|
| |||
Dimension,D*W*H(MM) | 584*425*180 | |||||
Net Weight(KGS) | 58.7/59 | 67/66.5 | 71.8/72 | |||
Environment |
|
|
| |||
Humidity | 5~95% relative humidity(Non-condensing) | |||||
Operation Temperature | -10~50℃ | |||||
Storage Temperature | -15~60℃ | |||||
Feature:
·Pure sine wave Inverter
·Output power factor 1
·Selectable charging current via LCD
·Selectable input voltage range for home appliances and personal computer
·Configurable AC/battery input priority Via LCD setting
·Configurable power saving mode via LCD setting
·Compatible with generator power
·Dry contact port generator to realize mutual control by generator and utility
·Auto restart when AC is recovering
·Overload and short circuit protection
·Small battery charger design for optimized battery performance
·Cold start function
·Smart fan running control to extend service life and reduce noise
·Support to run Lithium battery
·RS232 communication port and remote control panel optional