Share on (62518973535):
YG026B type electronic fabric strength machine
[use]
It is used to measure the breaking strength and elongation at break of various woven fabrics, non-woven fabrics, automotive interior parts, geotextile materials, cotton, wool, linen, chemical fiber and glass fiber.
[Standards compliant]
GB / T 3923.1-2013 Textiles - Tensile properties of fabrics - Part 1: Determination of breaking strength and elongation at break (strip method)
Textiles - Tear properties of fabrics - Part 2: Tearing strength of tongue - shaped test specimens GB / T3917.2-1997
Textiles - Tear properties of fabrics - Part 4: Determination of tear strength of tongue - shaped specimens (double slits) GB / T.
Determination of bursting strength of textiles - Steel ball method GB / T
Non - woven fabric peel strength test
[Features]
1, force measurement system: the use of high-precision sensors, identified by the State Bureau of Technical Supervision.
2, the controller: computer control, anti-interference ability, speed, sampling rate ≥ 1000 times / sec; and can simultaneously handle curves and statements.
3, display features: the process of dynamic tracking curve (monitoring), automatic scaling curve coordinates, statements and curves at the same time tracking display.
4, operating software: Chinese and English automatically switch, user-friendly.
5, operating characteristics: mobile phone-guided mode of operation, easy to operate.
[Instrument performance and main technical parameters]
1, the test method: constant-rate elongation (CRE) determination of principle, computer control, and record the dynamic changes in the curve. Strength / elongation, strength / time, elongation / time curves can be selected as desired.
2, the test method: stretching, breaking the top, torn
3, range: 1000N / 2000N / 3000N / 5000N (optional)
4, measuring force accuracy: <± 0.5%
5, the folder from: 25 ~ 500mm (stepless adjustable)
6, the tensile speed: 1 ~ 450mm / min (any setting)
7, recovery rate: 400mm / min
8, the effective range: 450mm (can be customized)
9, elongation resolution: 0.01mm
10, holder effective clamping width: optional (standard configuration: 55mm)
11, print: the output of various forms of data, curves and statistical results
12, power supply: AC220V ± 10% 50Hz
13, Dimensions: 600 × 430 × 1250mm
New products from manufacturers at wholesale prices