Aoyi SSR Series Single Phase Solid State Relay SSR 10DA with LED

Share on (62549861201):


Price:

Quantity:


Product Overview

Description



Overview



※Input signal can make compatible with TTL,CMOS etc logic circuit.
※Direct copper bonding(DCB)technology
※Opto-isolation over than 4000VACrms
※Switching method:zero-crossing &Triac Angle trigger.
※LED indication.
※Build-in resistance-capacitance absorption circuit.
※Actuation time:ON<10ms/OFF<10ms
※Clip-on IP20 protective cover.



Product Details


Model
SSR-□□DA
Rated Load Current
10A 15A 25A 40A 60A 75A 90A
Input Voltage
3-32VDC
Output Voltage
24-380VAC
Control Current
DC6-12mA
Min. ON/OFF Voltage
ON > 2.4V, OFF < 1.0V
Trigger Current
7.5mA/12V
Control Method
Zero Cross Trigger
Response Time
ON < 10ms , OFF < 10ms
Operating Temperature
-20℃ 〜+80℃




Selection




Mode
SSR-10DA
SSR-15DA
SSR-25DA
SSR-40DA
SSR-60DA
SSR-75DA
SSR-90DA
Power Voltage
220VAC
Appl Amp
<5A
<7.5A
<12.5A
<20A
<30A
<37A
<41A
Power
<1.1KW
<1.6KW
<2.7KW
<4.4KW
<6.6KW
<8.1KW
<9KW
Radiator
B-50
A-50
A-50 C-55
C-55
C-55 E-50


Wiring Diagram






Warning


1. Before you use , read safety precautions carefully, and use this product properly.

2. do not touch or contact the input/output terminals because they may cause electric shock.

3. The user must install the external safety equipment when there are possible defect of this product or serious accidents.

4. To prevent defection or malfunction of this product, supply proper power voltage in accordance with the rating.

5. To prevent electric shock or devise malfunction of this product, do not supply the power until the wiring is completed.

6. Reassemble this product while the power is off. Otherwise, it may cause malfunction or electric shock.

7. If the user use the product with methods other than specified by the manufacturer, there may be bodily injuries or property damages.

8. Due to the danger of electric shock, use this product installed onto a panel while an electric current is applied.



Caution


1. Before using the product you have purchased, check to make sure that it is exactly what you ordered.

2. Do not use this product at any place with corrosive ( especially noxious gas or ammonia) or flammable gas.

3. Do not use this product at any place with liquid, oil , medical substances, dust , salt or iron contents.(pollution level 1 or 2 )

4. Do not use this product at any place with excessive induction trouble, static electricity or magnetic noise.

5. Do not use this product at any place with possible thermal accumulation due to direct sunlight or heat radiation.

6. When the product gets wet, the inspection is essential because there is danger of an electric leakage or fire .

7. Do not connect anything to the unused terminals.

8. For dc types, connect wires at the correct position after checking polarity of terminal.

9. The rated heat sink must be used , otherwise , the product may be destroyed.

10. When product is disposed , treat as a industrial waste.



Factory Introduction