Air Cooled Screw Type Water Chiller with Heat Pump Core Components Motor and PLC One Stop Shopping for HVAC and Spare Parts

Share on (62569243605):


Price:$38,000.00

Quantity:


Product Overview

Description


750KW Screw Type Heat Pump Air Cooled Water Chiller



Product Description


 


The main unit is equipped with semi-hermetic screw compressor, integrating the motor, without worrying about shaft seal leakage.
The single or more compressors are provided with startup-shutdown cycle control program so as to uniformly load parts and extend service life. Multiple refrigerating circuits are provided for the unit, and when one circuit is under maintenance, other circuits are able to run normally as mutual standby. Unload and step down voltage start is provided for the compressors to prevent the impact on the power grid.
Ultra-low noise turbine blade design.
V-shaped appearance provides better heat dissipation.


 


The high-temperature unit is able to provide 55-60℃ hot water for air conditioning system, and the heat recovery type provides water for living, which conform to the Head-Power’s high requirements on energy saving.


 


The unit enjoys compact structure, covers small area, saves machine room space; it almost not vibrates due to the provision of foundation anti-vibrating measure.
Upon delivery of the unit, the refrigerant and lubricating oil have been filled into it, then it’s only necessary to connect the evaporator water pipe during installation, saving time and cost.


 


Intelligent program control can be achieved for the unit according to the load demand: 100%, 75%, 50%, 25% (or start), 0 and stepless energy adjustment, reducing energy consumption.
Total parts number of screw compressor is only 1/10 that of the reciprocating compressor, enabling the unit to have simple structure and less venerable parts, without the use of air intake and exhaust valves, not sensible to wet stroke and extremely low fault rate.
Failure-free operation time of the screw compressor is up to 40,000 hours.


 


Pressure protection: High and low-pressure protecting devices
Motor protection: Voltage-loss protection, phase-loss protection, inverse phase protection and over-heat protection. Anti-freezing protection: The unit will stop running in case of excessively low chilled water temperature
.
Above device protections ensure the safe and reliable running of the unit.


 









































































































































































































































































































































































































































































































Model NumberHWALR150HWALR200HWALR250HWALR330HWALR400HWALR500HWALR600HWALR500DHWALR650HWALR800DHWALR1000DHWALR1200D    
Cooling CapacityKW1501822453223884985964906457769961192    
Heating CapacityKW18521228538044556668357076089011121366    
Cooling Power InputKW48.257.77699118148183252198236296366    
Heating Power InputKW47567497113144178248194226288356    
Power Supply380V/3N~50Hz    
Energy Control0~25~50~75~100% / Infinitely Variable Control    
CompressorType6+7 Semi-closed Double Screw Type    
Number111111122222    
RefrigerantTypeR22,R407C    
Way of ThrottlingExternal Balance of Thermal Expansion Valve/ Electronic Expansion Valve    
Refrigerant Volume kg48627485115145162162171230290324    
Heat Exchanger of Air SideInternal Thread Copper Tube with Aluminium Fin    
Condensing FanType Ultra-low Noise Axial Fan    
PowerKW1.1*41.5*41.5*61.5*81.5*101.5*121.5*141.5*121.5*161.5*201.5*241.5*28    
Heat Exchanger of Water SideType Dry Shell and Tube     
Cooling Water Flowm³/h263243566786102.585111135172223    
Heating Water Flowm³/h28374966779811899131155192235    
Connection Pipe DN80DN80DN100DN100DN100DN125DN125DN125DN150DN150DN150DN200    
Water ResistanceKPa50~60    
Partial Heat RecoveryHeating CapacityKW556586114135170205170230268335410    
Hot Water Volumem³/h15.718.624.632.638.7495949667796118    
Total Heat RecoveryHeating CapacityKW1581802453253804805804856467569451160    
Hot Water Volumem³/h45529093109138166139185217270320    
Noise LeveldB/A646465656666676868697071    
DimensionsLengthmm230025003400440054006400740064008400105006400*27400*2    
Widthmm220022502250225022502250225022502250225022502250    
Heightmm220022502250225022502250225022502250225022502250    
Notice: 1. Nominal cooling condition:  inlet/outlet water temperature is 12/7℃, the air dry/wet bulb temperature is 35/24℃;     
2. Nominal heating condition:  inlet/outlet water temperature is 40/45℃, the air dry/wet bulb temperature is 7/6℃.    
3. The water supply of heat recovery refers to the water volume when the water temperature increases from 20℃ to 50℃.     
4. The above dimensions are just for reference, they are subject to change due to improvement.

 


1-15543862694.jpg2-15544065291.jpg3-15543768226.jpg4-15543840398.jpg5-15543934865.jpg


 