Share on (62574616970):

Thermocouple Types and Temperature Range | ||||||||
Type | Wire material | Temp. Range | Accuracy | |||||
+ | - | |||||||
K | Nickel-Chromium | Nickel-Alumel | -200˜1000°C | +/- 2.2C or +/- 75% | ||||
J | Iron | Constantan | 0˜600°C | +/- 2.2C or +/- 75% | ||||
T | Copper | Constantan | -200˜300°C | +/- 1.0C or +/- 75% | ||||
E | Nickel-Chromium | Constantan | -200˜700°C | +/- 1.7C or +/- 0.5% | ||||
N | Nicrosil | Nisil | -200˜1200°C | +/- 2.2C or +/- 75% | ||||
R | Platinum Rhodium -13% | Platinum | 0˜1400°C | +/- 1.5C or +/- 25% | ||||
S | latinum Rhodium - 10% | Platinum | 0˜1400°C | +/- 1.5C or +/- 25% | ||||
B | Platinum Rhodium – 30% | Platinum Rhodium – 6% | 0˜1500°C | +/- 0.5% | ||||