Сохранить в закладки 10000001695787:
3.5/7KW- AC400V type 2 specification
3.5/7KW- AC400V type 2 specification | |||||
Outlet specifications | (option) | ||||
Connection standard | IEC 61851-1 | ||||
Connector/socket type | IEC 62196-2 Type 2 Mode 3 | ||||
Vehicle Safety Communication | IEC 61851-1 PWM (AC Type 2) | ||||
System output voltage range | 400VAC | ||||
Number of output interface configuration modules | 3.5kW×1 | 7kW×1 |
| ||
Connector maximum output current | 16A | 32A |
| ||
Compliance and safety | CE | CE |
| ||
Cable length | 3.5m | 3.5m |
| ||
General specifications | |||||
Environment | Indoor / outdoor | ||||
Operating temperature | ,-20 ºC to +50 ºC(de-rating characteristic applies) Option: -35 ºC to +50 ºc | ||||
Storage temperature | ,-40 ºC to +70 ºC | ||||
RFID system | ISO/IEC14443A/B, | ||||
Payments | Smart Card, Server based Online Payments or equivalent | ||||
Network connection | 10/100 Base-T Ethernet(3G/4G option) | ||||
Interaction Display | Non 2.4 inch or Full-color (4.3 in 480x270 TFT ) LCD display for option | ||||
Visual Indicators | Error indication, Presence of input supply indication, Charge process indication and other relevant information | ||||
safety protection | Over current, under voltage, over voltage, Residual current, Surge protection, Short circuit, Earth fault at input and output, Input phase reversal, Emergency shut-down with alarm, Over temperature, Protection against electric shock | ||||
Push Button | Mushroom type emergency stop switch (Red) | ||||
Supported Communication Protocols | OCPP1.6 | ||||
Residual Current Device | Integrated type A | ||||
Protection | IP54 | ||||
Dimensions (D x W x H) | 650*380*160mm | ||||
Input Chracteristics | |||||
AC Supply System | single-Phase, AC system (1Ph.+N+PE) | ||||
Nominal Input voltage | 400VAC,±10% | ||||
Input Frequency | 50Hz, ±10Hz | ||||
Input Supply Failure backup | Battery backup for minimum 1 hour for the control system and billing unit. Data logs should be synchronized with CMS during back up time, in case battery drains out | ||||
Connector parameters 1# | |||||
Rated voltage | AC230V | ||||
Rated current | 1AC / 16A | 1AC / 32A |
| ||
standard | IEC 62196-2 Type 2 | ||||
Electromagnetic lock | NO | ||||
Temperature Sensor | NO | ||||
communication interface | PWM |
1.Q: How long is your lead time?
A: If for AC Charger, about 5-7 days; if for DC Charger within 5 units, about 20-25 days.
2.Q: What's difference between commercial type and home-using type?
A: Commercial type is configurated with OCPP1.6J, it allows you to connected to the network to check the charging management system and online card information through a protocol.
3. Q: What is OCPP?
A: OCPP is abbreviated for open charging point protocol, it is a kind of network protocol.You can connected to our management system in PC via it, and then manage the EV charger and online cards. Also, you could position the EV charger via OCPP. or do you have your own management system?
4.Q: Are your products can be connected to APP?
A: Yes, we could provide you with a port to connect your own APP.
5.Q: With RFID function, how's your payment procedure works?
A: There are two kind of cards,one is offline card without payment function, just swipe as a key to make Charger to operate. Another card is member card/white card/online card),we can save money inside in your back office, people hold the card to charge his car,and the amount will be reduced.
6.Q: Can I create extra cards?
A: Yes, just assure the card is conform to the following parameters:
ISO standard: 85.5*54mm
Working frequency: 13.56MHz/125KHz
Executive standard: ISO14443A
7.Q: Can I be your distributor?
A: Of course. First, there need be USD 5000 GMV during a year.Second, you need to provide us plan and summary monthly.