Сохранить в закладки 10000008311304:
Online UPS for IDEAL Choice 9300LB LV Tower 3KVA 3000VA Series
IDEAL-9303LB UPS Series is true sine wave double conversion Online UPS tower type model that provides output power factor 0.8 for high performance and efficiency. With Microprocessor control design, it lowers the defective rate of UPS to guarantee high reliability and to protect any critical applications. Individual PDU module is used as Power Distribution Unit in conjunction with IDEAL-9300LB 3KVA 3000VA UPS system, which will be more convenient and efficient when UPS needs maintenance service. 3KVA Online UPS
* Intelligent Slot (SNMP) and USB management software to monitor UPS status 3KVA Online UPS
* Individual power distribution unit (PDU) for fast and easy maintenance
* ECO mode High efficiency mode for power saving
* Wide input range for extreme voltage instability
* Advanced microprocessor control technology
* External battery bank to extend back-up time
* True double conversion Online UPS
* Emergency power-off EPO function Online UPS battery power system
* Automatic self-testing function Online UPS battery power system
Fast Delivery
UPS system works by converting power from AC to DC and then back to AC. Supplying power with zero transfer time to the battery to ensure uninterrupted back-up power when AC power is abnormal, make it ideal for any sensitive devices.
Supporting Wide Input Voltage range can offer stable power supplying even in bad AC environment.
Intelligent self-testing function can inspect battery and UPS status to avoid causing any negligence or loss.
Offering well and full range protection for computer center, accounting center, office and home applications. For On-Line UPS 3KVA 3000VA model(2400W), 9sets PC can be connected in the same time. Pure sine wave UPS 3000VA
Patent PDU module can save cost and labor hours on UPS maintenance. sine wave UPS systems
MODEL | IDEAL-9303LB | IDEAL-9303LBE | ||||
CAPACITY UPS | 3KVA/2.4KW 3000VA | |||||
INPUT | ||||||
Voltage | 1 Phase 2 Wires + Ground 100/110/115/120 Vac | |||||
Voltage Range | 100/110/115/120 Vac : 55-150 Vac | |||||
Frequency | 50Hz or 60Hz (Auto Sensing) | |||||
THDi | < 5% at full Load | |||||
OUTPUT | ||||||
Voltage | 100/110/115/120 Vac | |||||
Voltage Regulation | 100/110/115/120 Vac : < 1% | |||||
Frequency (Battery Mode) | 100/110/115/120 Vac : 50Hz or 60Hz +/- 0.1Hz | |||||
Waveform | Pure Sinewave | |||||
THD | 100/110/115/120 Vac : < 4% (Linear Load), < 8% (Non-linear Load) | |||||
Crest Ratio | 3:1 | |||||
EFFICIENCY | ||||||
To AC Mode | 100/110/115/120 Vac : > 89% at Full Load and Battery Full Charged | |||||
To Battery Mode | 100/110/115/120 Vac : > 85% at Full Load and Battery Full Charged | |||||
To ECO Mode | 100/110/115/120 Vac : > 95% at Full Load and Battery Full Charged | |||||
BATTERY | ||||||
Voltage | 72VDC | |||||
Type | 12V/9AH*6pcs | Extendable | ||||
Recharge Time | 5Hrs to 90% | Depend on Capacity of External Battery | ||||
TRANSFER TIME | ||||||
Line Mode to Battery Mode | 0ms | |||||
Inverter to Bypass, ECO Mode | < 4ms | |||||
ECO Mode to Inverter | < 10ms | |||||
DISPLAY | ||||||
LCD Display | Input, Output, Load, Battery, Mode/Fault/Warning code, Inverter operating, Bypass operating, Output voltage and frequency and Bypass disable / enable selection information | |||||
COMMUNICATIONS | ||||||
Interface (Port) | USB Port | |||||
Intelligent Slot | Slot for SNMP or AS400 card (Optional) | |||||
EPO | Emergency Power Off | |||||
ENVIRONMENT | ||||||
Temperature | 100/110/115/120 Vac : 0 - 40°C | |||||
Humidity | 20-90%, non-condensing | |||||
Acoustic Noise | 100/110/115/120 Vac : < 45dB at 1M | |||||
PHYSICAL | ||||||
Dimension(D*W*H) | 560*193*346mm | |||||
IDEAL POWER CO., LTD was founded in 1996 and committed to design and manufacture reliable and qualified full range of power products, including Uninterruptible Power Supply (UPS), Inverter, Automatic Voltage Regulator (AVR), Voltage Protector (VP) and Surge Protector (SP).
UPS systems
With more than 20 years' experience of OEM/ODM in power products, IDEAL POWER strives to achieve the mission to provide products with high quality and better performance to meet customers' demand in the world.
We, IDEAL, are dedicating on product development and training professional team, we focus on the global market trend to provide innovative power for customers. IDEAL engineering team has professional background experience and technical knowledge and skill, devoting to integrate global market tendency with new technology to ensure products meet the global customer demand. IDEAL design team help customer design customized product package to establish admirable corporate image for marketing.
We are convinced that establishing long-term relationship of mutual trust and mutual benefit between IDEAL and customers is the motion for us to thrive.
With well-trained and professional team, IDEAL support best service and qualified products to customers globally.
1) ODM/OEM experience for more than 20 years.
2) Well-organized manufacturing bases to meet worldwide growing demand.
3) Customized products to meet various applications.
4) Full range of power products
5) High quality products supported by strict quality control system
6) Well-trained workforce and engineer team.
7) Reliable manufacturing supplier on E-commerce online platform
Q1: Why you should install UPS?
When AC Power is off, UPS will offer emergency back-up power to your electronic devices for data loss protection. Power surges are a threat everywhere. UPS can provide fully power protection for over-voltage, under-voltage and surge to offer smooth and consistent flow of power quality to your appliances.
Q2: What electronic appliances should be protected?
All electronic appliances that need long programming times or have to be always accessible would be better to install with a UPS system. This includes computer, medical equipment, data center, server room, networking system and any important electronic appliances.
However, it is not recommended to connect UPS with laser printer or office multifunction fax/printer because they will draw a high initial inrush current at start-up. A typical UPS cannot deal with such a spike.
Q3: What factors can affect UPS battery life time?
Batteries must be kept at ambient temperature of 25°C (77°F). If battery is operated at higher temperatures, its average life will be shortened. The number and length of battery discharges affect a battery's efficiency to deliver power. The more or deeper discharges, the shorter the battery's life will be.
If a battery is undersized for a load, battery run time and life expectancy will also be shortened.
Therefore, it is recommended to replace the batteries every 3 years after initiating the unit.
Recharge batteries every 3 months is necessary if it is not in use.