Datasheet | Growatt SPH 3000 | Growatt SPH 4000 | Growatt SPH 5000 | Growatt SPH 6000 | ||||
Input Data | ||||||||
Max.DC power | 6600W | 6600W | 8000W | 8000W | ||||
Max.DC voltage | 550V | |||||||
MPP Voltage Range | 150-550/360V | |||||||
Number of MPP Trackers/Strings per MPP Trackers | 2/1 | |||||||
Max.Input Current per String | 12A | |||||||
AC Output (On-grid) | ||||||||
Rated AC output power | 3000W | 4000W | 5000W | 6000W | ||||
Max. AC output power | 3000VA | 4000VA | 5000VA | 6000VA | ||||
Max.output current | 16A | 22A | 22A | 27A | ||||
AC grid connection type | 230V, 50/60Hz | |||||||
AC Output (Back-up) | ||||||||
Max. AC output power | 3000W | 3000W | 3000W | 3000W | ||||
Rated AC output voltage | 230V | |||||||
Rated AC output frequency | 50/60Hz | |||||||
Switch time | 0.5s | |||||||
Battery data(DC) | ||||||||
Voltage range | 42-59V | |||||||
Recommended voltage | 58V | 58V | 58V | 58V | ||||
Charge current | 66A | |||||||
Battery type | Lithium/ Lead-acid | |||||||
Deep of discharge | 80%DOD/50%DOD | |||||||
Capacity of battery | 3~12KWh | |||||||
Protection Devices | ||||||||
DC reverse polarity protection | yes | |||||||
DC switch for each MPPT | yes | |||||||
Output AC overcurrent protection | yes | |||||||
Output AC overvoltage protection-varistor | yes | |||||||
Ground fault monitoring | yes | |||||||
Grid monitoring | yes | |||||||
Integrated all-pole sensiteve leakage current monitoring unit | yes | |||||||
Operating temperature range | -25℃ ~ +60℃ with derating above45℃ | |||||||
Noise emission | <35dB(A) | |||||||
Self-consumption(night) | <7W | |||||||
Topology | Transformerless | |||||||
Cooling concept | Smart cooling | |||||||
Environmental protection rating | IP65 | |||||||
Altitude | 2000m | |||||||
Relative Humidity | 0-100% | |||||||
Features | ||||||||
Display | LCD | |||||||
Interfaces | RS232/CAN/USB/Wi-Fi/RF | |||||||