Сохранить в закладки 1600069834395:
Outside-inside PVDF hollow fiber UF membrane filter
YOUBER Outside-inside PVDF hollow fiber UF membrane module for famous brand replacement
outside-inside PVDF Hollow fiber UF membranes filter Technical parameters:
Performance | Initial flow rate(T/H, 1Bar) | 3.5 |
Designed production flow rate(T/H,1Bar) | 1.0-2.0 | |
SDI | <1 | |
<0.1NTU | ||
SS removing rate | 99.9% | |
Microorganisms, bacteria, pathogens removing rate | 99.99% | |
Specification | Type | Outside to inside |
Membrane material | PVDF | |
Effective membrane area(m2) | 25 | |
Hollow fibers quantity | 6500pcs | |
Housing material | UPVC | |
Sealing material | Epoxy resin | |
Suggestion working conditions
| Suggest(TMP)(MPa) | 0.04-0.1 |
Max inlet water pressure(MPa) | 0.3 | |
Max TMP(MPa) | 0.2 | |
Working temperature | 5-45degrees | |
PH tolerance range | 2-13 | |
Tolerable residual chlorine concentration | 200PPm | |
Short - term tolerance to residual chlorine concentration | 500PPm |
Model:UF-2860
YOUBER Outside-inside PVDF hollow fiber UF membrane filter for famous brand replacement
Technical Parameters:
Model | UF-2860 |
Fibers material | PVDF |
Fibers ID/OD | 0.7mm/1.3mm |
WMCO | 0.03μm |
Pure water flow rate (0.2Mpa,25℃) | 25000L/H |
Design flow rate | 1500-4000L/H |
Active membrane area (inside-outside) | 51m2 |
Shell material | UPVC |
Sealing material | epoxy resin |
Inlet/outlet port size | DN50 |
Air inlet pore size | RP 3/8” |
Usage conditions | |
Pre-treatment | 50-150um |
Operation mode | Outside-inside |
Working pressure | 0.02-0.2Mpa |
Max inlet pressure | 0.3MPa |
Max TMP | 0.15MPa |
Max air flush flow rate | 12Nm³/H |
Inlet pH range | 2-12 |
Tolerated continuous residual chlorine concentration | 1000 ppm |
Tolerated interval residual chlorine concentration | 2000 ppm |
Working Temp. | 1℃-40℃ |
Inlet water quality | Turbidity≤50NTU |
Production water quality | |
*Production water Turbidity | < 0.1NTU |
*Silt density index (SDI) | < 1 |
Particles(>0.2µm) | 100% removal rate |
Microorganism, Pathogen | 99.99% removal rate |
Backwash design | |
Backwash frequency | One time per 15-60 min |
Backwash pressure | ≤0.2MPa |
Backwash flow rate | 100-150L/ H.m2 |
Backwash dosing drugs | 500PPm NaCLO |
Dosing backwash frequency | Suggestion: Chemically enhanced backwash every 1-7 days |
Adding air mode | Air scrubbing wash before backwash |
Air backwash frequency | One time per 30-60 min |
Air volume (Nm3/h) | 8-12 |
Chemical cleaning design | |
Chemical cleaning frequency | One time per 1-4months |
Acid cleaning agent | Citric acid, oxalic acid or hydrochloric acid (solution of PH=2) |
Alkaline cleaning agent | 0.5%NaOH+0.1%NaClO(solution of PH=12) |
Note: * test under municipal tap water as raw water < 5NTU |
Model:UF-1060
YOUBER Outside-inside PVDF hollow fiber UF membrane filter for famous brand replacement
Technical Parameters:
Model | YLUF-1060 |
Fibers material | PVDF |
Fibers ID/OD | 0.7mm/1.3mm |
Pore size | 0.03um |
Pure water flow rate (0.2Mpa,25℃) | 36000L/H |
Design flow rate | 2000-6000L/H |
Active membrane area (inside-outside) | 77m2 |
Shell material | UPVC |
Sealing material | |
Inlet/outlet port size | DN50 |
Air inlet port | RP 3/8” |
Usage conditions | |
50-150um | |
Operation mode | Outside-inside |
Working pressure | 0.02-0.2Mpa |
Max inlet pressure | 0.3MPa |
Max TMP | 0.15MPa |
Inlet pH range | 2-12 |
Tolerated continuous residual chlorine concentration | 1000 ppm |
Tolerated interval residual chlorine concentration | 2000 ppm |
Working Temp. | 1℃-40℃ |
Inlet water quality | Turbidity≤50NTU |
Production water quality | |
*Production water Turbidity | < 0.1NTU |
*Silt density index (SDI) | < 1 |
Particles(>0.2µm) | 100% removal rate |
Microorganism, Pathogen | 99.99% removal rate |
Backwash frequency | One time per 15-60 min |
Backwash pressure | < 0.2MPa |
Backwash flow rate | 100-150L/ H.m2 |
Backwash dosing drugs | 500PPm NaCLO |
Dosing backwash frequency | Suggestion: Chemically enhanced backwash every 1-7days |
Air added method | Air scrub before backwash |
Air volume (Nm3/h) | 8-12 |
Chemical cleaning design | |
Chemical cleaning frequency | One time per 1-4months |
Acid cleaning agent | Citric acid, oxalic acid or hydrochloric acid (solution of PH=2) |
Alkali cleaning agent | 0.5%NaOH+0.1%NaClO(solution of PH=12) |
Note: * test under municipal tap water as raw water < 5NTU |
Model:UF315-W10
YOUBER Outside-inside PVDF hollow fiber UF membrane filter for famous brand replacement
Technical Parameters:
Model | UF315-W10 |
Fibers material | PVDF |
Fibers ID/OD | 0.7mm/1.3mm |
WMCO | 0.03μm |
Pure water flow rate (0.2Mpa,25℃) | 20000L/H |
Design flow rate | 2380-7150L/H |
Active membrane area (inside-outside) | 90m2 |
Shell material | UPVC |
Sealing material | epoxy resin |
Inlet/outlet port size | DN65 |
Air inlet pore size | RP 3/8” |
Usage conditions | |
Pre-treatment | 50-150um |
Operation mode | Outside-inside |
Working pressure | 0.02-0.2Mpa |
Max inlet pressure | 0.3MPa |
Max TMP | 0.2MPa |
Max air flush flow rate | 7-12Nm³/H |
Inlet pH range | 2-12 |
Tolerated continuous residual chlorine concentration | 500 ppm |
Tolerated interval residual chlorine concentration | 1000 ppm |
Working Temp. | 5℃-40℃ |
Inlet water quality | Turbidity ≤ 30NTU |
Production water quality | |
*Production water Turbidity | < 0.1NTU |
*Silt density index (SDI) | < 1 |
Particles(>0.2µm) | 100% removal rate |
Microorganism, Pathogen | 99.99% removal rate |
Backwash design | |
Backwash frequency | One time per 30-60 min |
Backwash pressure | ≤0.2MPa |
Backwash flow rate | 100-150L/ H.m2 |
Backwash dosing drugs | 15-20PPm NaCLO |
Dosing backwash frequency | Suggestion: automatic dosing drugs while each time need to backwash |
Adding air mode | Air scrubbing wash before backwash |
Air backwash frequency | One time per 30-60 min |
Chemical cleaning design | |
One time per 1-4months | |
Acid cleaning agent | Citric acid, oxalic acid or hydrochloric acid (solution of PH=2) |
Alkaline cleaning agent | 0.5%NaOH+0.1%NaClO(solution of PH=12) |
Note: * test under municipal tap water as raw water < 5NTU |
Model:UF-0880W
YOUBER Outside-inside PVDF hollow fiber UF membrane filter for famous brand replacement
Technical Parameters:
Model | UF-0880W |
Fibers material | PVDF |
Fibers ID/OD | 0.7mm/1.3mm |
WMCO | 0.03μm |
Pure water flow rate (0.2Mpa,25℃) | 17000L/H |
Design flow rate | 2040-6120L/H |
Active membrane area (inside-outside) | 77m2 |
Shell material | UPVC |
Sealing material | epoxy resin |
Inlet/outlet port size | DN50 |
Air inlet pore size | RP 3/8” |
Usage conditions | |
Pre-treatment | 50-150um |
Operation mode | Outside-inside |
Working pressure | 0.02-0.2Mpa |
Max inlet pressure | 0.3MPa |
Max TMP | 0.2MPa |
Max air flush flow rate | 7-12Nm³/H |
Inlet pH range | 2-12 |
Tolerated continuous residual chlorine concentration | 500 ppm |
Tolerated interval residual chlorine concentration | 1000 ppm |
Working Temp. | 5℃-45℃ |
Inlet water quality | Turbidity≤50NTU |
Production water quality | |
*Production water Turbidity | < 0.1NTU |
*Silt density index (SDI) | < 1 |
Particles(>0.2µm) | 100% removal rate |
Microorganism, Pathogen | 99.99% removal rate |
Backwash design | |
Backwash frequency | One time per 30-60 min |
Backwash pressure | ≤0.2MPa |
Backwash flow rate | 100-150L/ H.m2 |
Backwash dosing drugs | 15-20PPm NaCLO |
Dosing backwash frequency | Suggestion: automatic dosing drugs while each time need to backwash |
Adding air mode | Air scrubbing wash before backwash |
Air backwash frequency | One time per 30-60 min |
Chemical cleaning design | |
Chemical cleaning frequency | One time per 1-4months |
Acid cleaning agent | Citric acid, oxalic acid or hydrochloric acid (solution of PH=2) |
Alkaline cleaning agent | 0.5%NaOH+0.1%NaClO(solution of PH=12) |
Note: * test under municipal tap water as raw water < 5NTU |
Model:UF-0860W
YOUBER Outside-inside PVDF hollow fiber UF membrane filter for famous brand replacement
Technical Parameters:
Model | UF-0860WZ |
Fibers material | PVDF |
Fibers ID/OD | 0.9mm/2.0mm |
WMCO | 0.1μm |
Pure water flow rate (0.2Mpa,25℃) | 15000L/H |
Design flow rate | 1280-3520L/H |
Active membrane area (inside-outside) | 32m2 |
Shell material | UPVC |
Sealing material | epoxy resin |
Inlet/outlet port size | DN50 |
Air inlet pore size | RP 3/8” |
Usage conditions | |
Pre-treatment | 50-150um |
Operation mode | Outside-inside |
Working pressure | 0.02-0.2Mpa |
Max inlet pressure | 0.2MPa |
Max TMP | 0.15MPa |
Max air flush flow rate | 12Nm³/H |
Inlet pH range | 2-12 |
Tolerated continuous residual chlorine concentration | 1000 ppm |
Tolerated interval residual chlorine concentration | 2000 ppm |
Working Temp. | 5℃-40℃ |
Inlet water quality | Turbidity ≤30NTU. (should add pretreatment while using surface water, river/well water, etc. can use cartridge filter(<150um) to make feed water turbidity ≤30NTU) |
Production water quality | |
*Production water Turbidity | < 0.2NTU |
*Silt density index (SDI) | < 1 |
Particles(>0.2µm) | 100% removal rate |
Microorganism, Pathogen | 99.99% removal rate |
Backwash design | |
Backwash frequency | One time per 30-60 min |
Backwash pressure | ≤0.1MPa |
Backwash flow rate | 100-150L/ H.m2 |
Backwash dosing drugs | 15-20PPm NaCLO |
Dosing backwash frequency | Suggestion: automatic dosing drugs while each time need to backwash |
Adding air mode | Adding air when backwash |
Adding air backwash inlet volume | Air water ratio 1:1 |
Air backwash frequency | One time per 30-60 min |
Chemical cleaning design | |
Chemical cleaning frequency | One time per 1-4months |
Acid cleaning agent | Citric acid, oxalic acid or hydrochloric acid (solution of PH=2) |
Alkaline cleaning agent | 0.5%NaOH+0.1%NaClO(solution of PH=12) |
Note: * test under municipal tap water as raw water < 5NTU |
outside-inside PVDF Hollow fibers:
Outdoor outside-inside Hollow fiber UF Ultrafiltration Membrane filter:
Hollow fiber UF Ultrafiltration Membrane filter Packaging: Standard export carton package
YOUBER is a professional producer and provider of water treatment, we can accoding to the customers' requirements to do different membranes with different materials and different precision.
1.We are a professional manufacturer of Hollow fiber UF Ultrafiltration Membrane filter;
2. We can provide various dimension, different membrane materials like PVC, PES, PVDF etc, various filtration precision, various flow rate and performance personalized UF membrane module;
3. We can provide OEM, ODM service;
4. We also can provide membrane system desgin, installation, commisioning, maintenance service guidance and so on.
Welcome to YOUBER!
Новинки товаров от производителей по оптовым ценам