Product name process | Intelligent reactive power compensation controller |
Product model | FJK-02-32F(B) |
Product Brief | Fjk-02-32f intelligent reactive power compensation controller is a new type of distribution measurement and control equipment which integrates data collection, communication, reactive power compensation, power grid parameter analysis and other functions. It is suitable for the monitoring and reactive power compensation control of AC 0.4kV, 50Hz low-voltage distribution system. |
Functional characteristics | Fjk-02-32f intelligent reactive power compensation controller, with high-speed digital signal 32-bit processor as the core, adoptsAC sampling, human-machine interface is 128X64 lattice large LCD, which has power distribution monitoring, power consumptionmeasurement, reactive power compensation, harmonic analysis, event recording, temperature sensor interface (optional), adaptivefrequency algorithm, input signal changes between 45Hz and 55Hz. The equipment provides RS232, RS485 (one of the two) and can communication ports. The communication mode supports GPRS, wirelesscommunication, twisted pair, coaxial cable, data transmission radio, etc. the optical modem and optical fiber can also be used for communication. Combined with the communication part, it can also communicate with the SCADA master station to complete variousmonitoring functions of the distribution line. The installation conforms to DIN standard, with two installation methods of embedded / wall mounted. |
Conditions of use | 1. The altitude is not higher than 2500m 2. Ambient temperature - 25 ° C to + 65 ° C. 3. Atmospheric pressure 79.5kpa-106kpa 4. The air temperature shall not exceed 50% at 40 ° C and 90% at 20 ° C. 5. The surrounding environment is free of corrosive gas, conductive dust and inflammable and explosive media. 6. There is no violent vibration at the installation site |
technical data | 1. Rated working voltage: AC380V 50Hz 2. Rated working current: ac0-5a 50Hz 3. Output contact capacity: DC12V / 40mA or 220V / 5A 4. Display power factor: 0.001 lagging - 0.001 leading 5. Measured reactive power: 0-9999kvar 6. Undervoltage protection value: AC 300V 7. Control mode: automatic optimization / cycle switching 8. Sensitivity: 50mA 9. Protection class: enclosure IP40 |
Product name | Reactive compensation controller |
model | FJK-02-32F(B) |
Control the number of switching paths | 32 |
Compensation type | Hybrid compensation |
Product description | Connected to AC contactor, LCD, 32 channel output, harmonic detection. . |