Сохранить в закладки 1600411145562:
Model Name | SG110CX | SG5K-D | SG6K-D | SG8K-D | ||||
Input DC | ||||||||
Max. input voltage | 1100V | |||||||
Min. input voltage | 200V | |||||||
Start-up voltage | 250V | |||||||
Rated input voltage | 585V | |||||||
MPPT voltage range | 200-1000V | |||||||
Max. current for input connector | 26A*9 | |||||||
Max. short circuit current | 40A*9 | |||||||
MPPT number | 9 | |||||||
Output DC | ||||||||
Rated out power | 110 kVA @ 45 ℃ / 100 kVA @ 50 ℃ | 5000W | 6000W | 8000W | ||||
Max. AC output current | 158.8A | 22.7A | 273.A | 34.8A | ||||
Rated grid voltage | 3/N/PE, 400V | |||||||
AC voltage range | 320-460 V | |||||||
Rated grid frequency | 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz | |||||||
THDi | <3% (of nominal power) | |||||||
DC current injection | <0.5%(of nominal current) | |||||||
Power Factor | >99%(0.8 leading-0.8 lagging) | |||||||
Feed-in phases / Connection phases | 3/3 | |||||||
Efficiency | ||||||||
Max. efficiency | 98.7% | |||||||
Max. European efficiency | 98.5% | 98.0% | 98.0% | 98.1% | ||||
Protection | ||||||||
DC reverse connection protection | Yes | |||||||
AC short circuit protection | Yes | |||||||
Leakage current protection | Yes | |||||||
Grid monitoring | Yes | |||||||
Ground fault monitoring | Yes | |||||||
PV string current monitoring | Yes | |||||||
DC switch | Yes | |||||||
PID recovery function | Yes | |||||||
Overvoltage protection | DC Type II/AC Type II | |||||||
General Data | ||||||||
Dimensions (W*H*D) | 1051*660*362.5 mm | |||||||
Weight | 89kg | |||||||
Topology | Transformerless | |||||||
Self consumption | <2W (night) | |||||||
Operating ambient temperature range | -30 ~ +60°C | |||||||
Relative humidity | 0-100% | |||||||
Ingress protection | IP66 | |||||||
Max. operation altitude | 4000m | |||||||
Cooling method | Smart forced air cooling | |||||||
Grid connection standard | VDE-AR-N 4105, VDE V 0124, VDE V 0126-1-1, UTE C15-712-1, NRS 097-1-2, G98, G99, EN 50549-1/-2, UNE 206006, UNE 206007-1, IEC 61727 | |||||||
Safety/EMC standard | IEC 62109-1/-2, IEC 62116, EN 61000-6-1/-2/-3/-4 | |||||||
Communication | WIFI/ Ethernet (optional) | |||||||
DC connection | MC4 (Max. 6 mm²) | |||||||
AC connection | OT / DT tERMINAL | |||||||
Display | LED | |||||||
Compliance | Active & reactive power control, power ramp rate control |
Payment Terms | T/T | EXW | 30% T/T in advance, paid the balance before shipment | ||
FOB | |||||
L/C | CFR(C&F) | 30% T/T in advance, paid the balance against copy of B/L | |||
CIF | |||||
L/C amount above 50,000 USD, we can accept L/C at sight | |||||
West Union | Amount lower than 5000 USD | ||||
Delivery Time | 7~10days after receiving payment for one container |