Analytical system | ||||
Model | P100 | |||
Liquid Infusion System | Dual-piston reciprocating parallel pump, equipped with a binary high-pressure mixer | |||
Flow Rate Range | 0.001-10 mL/min | |||
Max Output Pressure | 42 MPa | |||
Flow Accuracy | <±1% | |||
Flow Precision | RSD<0.07% | |||
Qualitative Repeatability | RSD6 w 0.1% (naphthalene/methanol standards) | |||
Quantitative Repeatability | RSD6 < 0.3% (naphthalene/methanol standards) | |||
Pressure Fluctuation | 0.1Mpa | |||
Power Supply | 220V/110V | |||
Semi-preparation system | ||||
Model | P100SP (40 mljsemi-preparation system | |||
Flow Rate Range | 0.01 -40 mL/min | |||
Prsssure Range | 0-25 MPa | |||
Flow Accuracy | ±2% | |||
Flow Rate Accuracy | RSD<0.1% | |||
High pressure semi-preparation system and High pressure preparation system | ||||
Model | PlOOHSP(SOmL) high pressure semi-preparation System | Pl00HP(120mL) high pressure preparation system | ||
Flow Rate Range | 0.01-50 mL/min | 0.01-120 mL/min | ||
Prsssure Range | 0-42 MPa | |||
Flow Accuracy | ±2% | |||
Flow Rate Accuracy | RSD |
Model | UV-100UV detector | UV-VIS100 detector | UV-100S preparative UV detector | |||
Flow Cell Volume | 8ul | 8ul | 6ul | |||
Light Source | D2 lamp | D2 lamp+W lamp | D2 lamp | |||
Wavelength Range | 190-680 nm | 190-900 nm | 190-680 nm | |||
Spectrum Bandwidth | 8nm | |||||
Wavelength Accuracy | 士1nm | |||||
Wavelength Precision | Below 0.1 | |||||
Noise | <0.25 x 10 5AU (static)/士 1x1 OSAU (dynamic, under given conditions) | |||||
Drift | < 0.4x10 4AU/h (static) / < 2 x 10 4AU/h (dynamic, under given conditions) | |||||
Minimum Detectable Concentration | 3xl09g/mL(naphthalene/methanol solution) | |||||
Rl Detector | ||||||
Model | RI 100 | |||||
Effective range for refractive | 1.00-1.75 RIU | |||||
Temperature control optical bench | 7°C above ambient temperature 35 °C up to 55 °C in 1 °C steps | |||||
Noise (Analog signal) | 7nRIU(±7uV) | |||||
Noise (Digital output) | 3nRIU(±3uV) | |||||
Drift | < 1uRlU/h (< 1 mV/h) | |||||
Signal range (recorder) | Selectable: 10 mV, 100 mV, 1000 mV | |||||
Flower cell volume | 4 ul/ Micro , 9 uL/Analytically , 13 uL / Semi-preparative | |||||
Max Pressure | 6 bar (0.6 MPa) | |||||
Max Flow rate | 0.1 - 3.0 mL/min | |||||
DAD100 Detector | ||||||
Wavelength Range | 200-900nm (200-600*) Above 600 nm just for W lamp | |||||
Arrays | 512 | |||||
Spectrum Bandwidth lOnm | 10nm | |||||
Light Source | D2 lamp + W lamp | |||||
Noise | ±5x105AU | |||||
Drift | 5x10-4AU | |||||
Sample Rate | max 100Hz | |||||
Interface | LAN USB R232 | |||||
ELSD Detector | ||||||
Model | ELSD 100 | |||||
Light Source | Laser diode with correction optical mirror, 670 nm, and maximum output being less than 5mW, in compliance with FCC safety standards | |||||
Detection Element | Silicon photoelectric diode | |||||
Temperature Range | Room temperature to 110°C | |||||
Nebulizer Gas | Nitrogen is optimal, maximum 3.0L/min | |||||
Pressure Range | 15-90 psi | |||||
Mobile Phase Flow Rate | 0-5 mL/min | |||||
Analog Output | 0-1 V or 0-10 mV | |||||
Parameter | Use keyboard to enter operation parameters | |||||
Display | LCD | |||||
FLD100 Detector | ||||||
Flow Cell Volume | 16uL | |||||
Excitation Wavelength | 200-890 nm | |||||
Emission Wavelength | 210-900 nm | |||||
Wavelength Precision | 3nm | |||||
S/N | >720 |