Неэлектрифицированный Гибридный инвертор с немодулированным синусоидальным сигналом 1000 Вт 15000 2000 12 В постоянного тока переменного

Сохранить в закладки 1600533587754:


Цена:15 456,51 ₽ - 17 112,56 ₽*

Количество:

  • В избранное

Описание и отзывы

Характеристики



Product Description


Inverter Feature

1. Low frequency toroidal transformer increase efficiency,Pure sine wave output;


2. Integrated LCD display; One-button start with an external display screen( optional);


3. Dedicated DCP chip design; stable and high-speed operation;


4.LCD display, easy to monitor the operation condition in real time;


5. AC charge current 0-30A adjustable; battery capacity configuration more flexible;


6. Three types working modes adjustable:AC first, DC first, energy-saving mode;


7. AVR output, all-around automatic protection function;


8. Built-in PWM or MPPT controller optional;


9. Added fault codes query function,facilitate user to monitor the operation state in real time;


10. Supports diesel or gasoline generator, adapt any tough electricity situation;


11. RS485  communication port/APP optional.


 


Product Detail

 


DP inverter.jpg


1.jpg2.jpg3.jpg4.jpg



 


 


Inverter Technical Parameters












































































































































































































































































Specification
Model: DP/DP-T10212/24/4815212/24/4820212/24/4830224/4840224/48502486024870248
Rated Power1000W1500W2000W3000W4000W5000W6000W7000W
Peak Power(20ms)3000VA4500VA6000VA9000VA12000VA15000VA18000VA21000VA
Start Motor1HP1.5HP2HP3HP3HP4HP4HP5HP
Battery Voltage12/24/48VDC24/48VDC24/48VDC48VDC
Size(L*W*Hmm)555*297*184615*315*209
Packing Size(L*W*Hmm)620*345*255680*365*280
N.W.(kg)121315.5182324.52627.5
G.W.(kg)(Carton Packing)141517.52025.52728.530
Installation MethodWall-Mounted
Parameter
InputDC Input Voltage Range10.5-15VDC(Single battery voltage)
AC Input Voltage Range85VAC~138VAC(110VAC)/ 95VAC~148VAC(120VAC / 170VAC~275VAC(220VAC / 180VAC~285VAC(230VAC)
/ 190VAC~295VAC(240VAC)
AC Input Frequency Range45Hz~55Hz(50Hz) / 55Hz~65Hz(60Hz)
Max AC charging current0~30A(Depending on the model)
AC charging methodThree-stage (constant current, constant voltage, floating charge)
OutputEfficiency(Battery Mode)≥85%
Output Voltage(Battery Mode)110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2%   
Output Frequency(Battery Mode)50/60Hz±1%
Output Wave(Battery Mode)Pure Sine Wave
Efficiency(AC Mode)>99%
Output Voltage(AC Mode)110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10%   
Output Frequency(AC Mode)Follow input
Output waveform distortion
(Battery Mode)
≤3%(Linear load)
No load loss(Battery Mode)≤0.8% rated power
No load loss(AC Mode) ≤2% rated power( charger does not work in AC mode)
No load loss(Energy saving Mode)≤10W
Battery TypeVRLA BatteryCharge Voltage :14V; Float Voltage:13.8V( 12V system; 24V system x2 ; 48V system x4)
Customize batteryCharging and discharging parameters of different types of batteries can be customized according to user requirements
 (charging and discharging parameters of different types of batteries can be set through the operation panel)
ProtectionBattery undervoltage alarmFactory default: 11V(12V system; 24V system x2; 48V system x4)
Battery undervoltage protectionFactory default: 10.5V(12V system; 24V system x2; 48V system x4)
Battery overvoltage alarmFactory default: 15V(12V system; 24V system x2; 48V system x4)
Battery overvoltage protectionFactory default:  17V(12V system; 24V system x2; 48V system x4)
Battery overvoltage recovery voltageFactory default:  14.5V(12V system; 24V system x2; 48V system x4)
Overload power protectionAutomatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protectionAutomatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection>90°C(Shut down output)
AlarmANormal working condition, buzzer has no alarm sound
BBuzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
CWhen the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller
(Optional)
Charging ModePWM or MPPT
Charging current10A~60A(PWM or MPPT)10A~60A(PWM )  / 10A~100A(MPPT)
PV Input Voltage RangePWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system)
MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system)
Max PV Input Voltage(Voc)
(At the lowest temperature)
PWM: 50V(12V/24V system); 100V(48V system) / MPPT: 150V(12V/24V/48V system)
PV Array Maximum Power

12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/


700W(50A)/840W(60A)/1120W(80A)/1400W(100A);
24V system: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/


1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A);
48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/


2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A)


Standby loss≤3W
Maximum conversion efficiency>95%
Working ModeBattery First/AC First/Saving Energy Mode
Transfer Time≤4ms
DisplayLCD(External LCD Display(Optional))
Thermal methodCooling fan in intelligent control
Communication(Optional)RS485/APP(WIFI monitoring or GPRS monitoring)

 


 


Wiring Diagram

DP-INVERTER-3KW-WIRING.jpg


 


 





Application Case


DP-Inverter-Installation.jpg


DP-Inverter-Case-2.jpg 





Packaging & Shipping


DP-2.jpg


Package
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.

Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.


 



Company Information

About Us


9.jpg10.jpg


 


Workshop

 


10_01.jpg10_02.jpg




Exhibition

11_01.jpg11_02.jpg


 


Certificate

wd2_21.jpg 


 



Related Products

















FAQ 


A: Are your inverters pure sine wave output?


Q: A Yes, All are true pure sine wave.


 


A: What kind of output you can do?


Q: Normally we produce inverter with 110V 115V 120V 220V 230V 240V, 50/60Hz self-adaption. If you have special requirements, please tell us for engineer consulting.


 


A: What' s the difference between low frequency and high frequency inverter?


Q: Low frequency inverter has various protections, strong ability to adapt to the environment. more reliable, with voltage regulation.


 


A: What's the difference between pure sine wave inverter and modified sine wave inverter?


Q: Pure sine wave output inverter is just as good as the Public power grid. Even better. Low repaired rate, long lifespan, Without harmonic pollution,  enviromental-friendly and appliances protected.


Modified sine wave output has a negative impact on appliances and can't load inductive load, such as air contition, refrigerator and etc. Certain motor control circuits don't like the modified wave.


 


A: What appliances your inverters can load?


Q: Our inverter can be used in household, Office, agricultural appliances and other inductive load such as refrigerator, air conditioner, water pump, etc.


 


A: Can you print our company logo on inverters, nameplates and packaging?


Q: Yes, we accept OEM orders.


 


A: How to choose a right inverter?


Q: Tell us your demand, then our sales will recommend a suitable inverter to you.


 


A: How to solve the technical problem?


Q: 24 hours after-service consultancy just for you and to make your problem to solveeasily.


 


A: Do I Need A Power Inverter?


Q: Actually, no. This is the only component of a solar energy system that is not absolutely required. However, if you don't use one, you will not have 220 or 230 volts AC and will have use battery power alone. This might be acceptable in a small RV or cabin, but most people want to use normal AC appliances.


 


A: What's The Difference Between 12, 24, And 48 Volt Inverters?


Q: This refers to the input voltage from the battery bank. The main consideration is that at higher voltages the current is less so that you can use smaller wires between your solar panel array and your battery bank. Of course, when you decide on a system voltage, the Solar Panels, Inverter, and Battery Bank all need to use the same voltage.


 


A: What to do if the product is broken? 


Q: If any product is faulty, you can send the picture or video to us, we sill study it and supply the spare parts of PCB board free for after sale service.




Похожие товары

Новые поступления

Новинки товаров от производителей по оптовым ценам