Сохранить в закладки 1600566014274:
| Model | AZ8701 AZ8703 AZ8705 | AZ8706 AZ8716 AZ8726 | AZ8708 AZ8709 | AZ8721 | AZ8723 | AZ8736single pass AZ8746dual pass |
| Type | Integrated | Integrated | Integrated | Split | Integrated | |
| Function | Temperature; Humidity; Dew point (only 8703/8704); Wet bulb temperature (8705 only)
| Temperature; Humidity; Dew point temperature; Wet bulb temperature; Calculate temperature difference (8716 only); 99 Memories (8726 only) | Temperature; Humidity; | Temperature; Humidity; Dew point; High and Low alarm settings | Temperature; Humidity; Dew point; Wet bulb temperature; High and Low alarm settings | Temperature; Humidity; Dew point; Wet bulb temperature; External K-type |
| Measuring range | Temperature -10~50℃; Humidity 5-95% RH; Dew point -68.5~50℃; Wet bulb -21.6~50℃
| Temperature -20~50℃; Humidity 0-100% RH; Dew point -78.7~50℃; Wet bulb -21.6~50℃
| Temperature -10~50℃; Humidity 5-95% RH; | Temperature -20~50℃; Humidity 0-100% RH; Dew point -50~50℃; | Temperature -10~60℃; Humidity 0-100% RH; Dew point -68~49.9℃; Wet bulb -13.4~59.9℃: | Temperature -20~50℃; Humidity 0-100% RH; Dew point -78.7~50℃; Wet bulb -21.6~50℃; K-type: -200~1370℃ |
| Resolution | 0.1℃,0.1%RH | |||||
| Accuracy | ±1℃,±4%RH | ±0.6℃,±3%RH | ±1℃,±3%RH | ±1℃,±2%RH | ±0.6℃,±3%RH | |
| Conversion of units | √ | √ | √ | √ | √ | √ |
| MAX Value | √ | √ | √ | √ | √ | √ |
| MIN value | √ | √ | √ | √ | √ | √ |
| HOLD lock | √ | √ | √ | √ | √ | √ |
| Backlight function | × | √ | × | √ | √ | √ |
| External temp. probe | × | Optional | × | × | × | K-type Optional |
| RS232 software | × | × | × | Optional | Optional | Optional |
| Size mm | 170*48.5*16.5 | 178.5*48.4*24.7 8726/230*57*44 | 175*42*16 | 180*67*30 | 175*70*33 | 230*57*44 |
| Battery Type | 2AAA | 2AAA,8726:4AAA | 1 CR2032 | 1section 9V | 4AAA | 4AAA |
| Operating Environment | 0-50℃,0-90%RH | |||||
| Description | The K-type temperature range of AZ8736/8746 is only the display range of the instrument, and the temperature measurement range depends on the probe. The standard thermocouple wire is mainly used for measuring temperature within -50~200 degrees. If you need to measure the high temperature of liquid or solid, please choose a probe. Select a suitable probe according to the product to be measured. | |||||
LIMET was founded in 2003, which is a professional supplier of testing instrument in the fields of environmental testing product. The product scope covers including water quality meter, PH meter, ORP meter, TDS meter, COND meter, Dissolved Xxygen Meter, Air quality testing meter, Thermometer, Hygrometer, Thickness meter, Manometer, Anemometer, Data logger, Gas leak detector, Vibrometer, Distance testing meter, Infrared thermometer ,Sound level meter...etc,.




Новинки товаров от производителей по оптовым ценам







Q1: How long can you make delivery after we put order for this meter?