Производитель VFD 0 75 400 кВт преобразователь частоты для солнечного

Сохранить в закладки 1600608961347:


Цена:*

Количество:

  • В избранное

Описание и отзывы

Характеристики


 


 




















































































































































 ItemDetailed information 
control characteristiccontrol modeV/F  control , open loop vector control , torque control 
range of output frequency 0-500.00Hz(v/f highest 3200.0Hz)
frequency setting resolution0.01Hz
ouput frequency setting resolution 0.01Hz
PWM carrier frequency adjust from 0.5Khz to 12khz
torque boostopen loop vector control(SVC):G type:0.5Hz/150%,P type 0.5Hz/120%
V/F curvethree types :line, multi-point. Nth power v/f curve
(1.2th power ,1.4th power ,1.6th power ,  1.8th power ,2th power
v/f separation twp types : full separation , semi-separation
Jump frequency adjust from 0.1hz to 500.00hz
acceleration/deceleration time 0.00 to 65000 seconds(4-stage acceleration/deceleration time is set independetly)linear or S-curve acceleration/deceleration mode
over current stall prevention levelcan be set according to the motor load charactreristics with 100-200% of the rated current of the driver
DC brake when stopping , it can be operated from 0.00 to the maximum operating frequency , and the braking current is 0 to 100% of the rated current;Start time 0-100.0 seconds, stop time 0-100.0 seconds
Brake torque20%(external optional brake resistor can reach 125%)
(1-30HP brake transistor built-in,40HP and above can be connected to the external brake unit module
operation charactreisticSpeed ratioopen loop vector control :1:100
Frequency  setting signalbit operation board :set by 
external terminal :0-10VDC,4-20mADC, Serial communication(RS485)
Operation signalbit operation board :Available to be oerated by RUN, STOP, JOG keys
external terminal :2-wire/ 3-wire operation ,jog operation , serial communication(RS485)
Input terminal of multi-functionForward and reverse running, three-wire operaton control, Forward and reverse jog running,free stop, reset fault, running pause, external fault input, increment /decrement frequency terminal setting,16-segment prese speed switching,acceleration/deceleration time switching ,frequency
source switching, running command switching,PID control, PLC status
 reset, pause swing frequency, reset swing frequency, prohibit acceleration and deceleration, disable torque control, calculator function, length count frequency increase and decrease setting clear, high speed pulse
 frequency , stop DC braking, frequency modification enable, speed control and torque control switching, clear running time of this time.
 
output terminal of multi-functionInverter operation, fault output, frequency level detection FDT output
 frequency arrival, zero speed operation,overload pre-alarm count value arrival length arrival, PLC cycle completion, cumulative running time
ItemDetailed  information
 arrival ,frequency limitation , torque limit ready to run , ACI1>AVI2, upper limit frequency  arrival ,lower limit frequency arrival(operation related). undervoltage status output, communication setting , cumulative power-on time arrival , frequency arrival output , timing arrival output, offload , recerse
In operation , the zero current state, the module temperature reaches , the output current exceeds the limt, the lower limit frequency  arrives(the stop is also output ) the alarm output (contrinues to run ) and the running time arrives
analog signal outputcorresponding to the actual output frequency , output current , output voltage,etc.
fault signal contact contact"ON"(one "C" contract relay or two open collector outputs when the AC drive fails
inner function

 Output frequency upper and lower limit seing, instantaneous power failure restart abnormal fault restart speed tracking
 Simple PLC.multi-speed operation,PID control, timing control Automatic regulated output regulation
 Abnormal record. parameter lock, parameter factory reset
 Reverse rotation prohibited,overcurent stall prevention, overvoltage stall prevention, electronic thermal relay
 
protection function Short circuit protection, acceleration over current, deceleration over current, constant speed over current, acceleration over voltage.
 deceleration over voltage, constant speed over voltage, bus undervoltage fault. motor overload. inverter overload. over torque protection, loss phase protection function  on the input (7.5G/11P and above),loss phase on the output , module
 overheating. external fault, communication fault, current detection fault. motor self-leaming faut, parameter read and write abnormality, inverter hardware abnormality, motor short circuit to ground., running time arrival. the power-on time arrives, the load dropped. the PID feedback disconnected. and the fast current limit timeout
  number of part on keypadContains 8 function keys,5-digit8-segment LED display,7 status indicato LED lightsCan set the frequency,display the actual output frequency.
output current, user-defined unit Parameter browsing and modification settings and parameter locking,abnormal fault display
Executable operation, stop,reset, forward/reverse, jogging
environmentoperation  temperature _10℃ to + 50℃( + 40℃~ + 50℃ below 90% RH, No condensation)
temperature of stock.-20℃ to .+60℃
humidity of opeation environmentbelowe 90%RH,NO  condenstaion 
height  of installtion no more than 1000m in height, no corrorsive gas, liquid , dust
vibation Below 20Hz 9.80665m/s²(1g), 20-50Hz 5.88m/s²(0.6g)
enclosureIP20(Depending on the end customers`s installation environment)
Note: the instantaneous power failure compensation time varies due to the inverter capacity.If a long instataneouspower failure time is required, the external"instantaneous power failure compensation device can be added






 