Звукоизоляционный тип 1000 кВт дизельный электрический генератор 1250KVA с MTU
190 300,00 $ - 192 300,00 $
Сохранить в закладки 1600618688408:
★★20KW CUMMINS diesel gensets specification★★ | ||
★Diesel gensets parameter: | ||
Model number:KWHQ20GF | Steady state voltage regulation(%):≤±1 | |
Output power:20KW | Voltage fluctuation rate(%):≤±0.5 | |
Pwer factor:COSΦ=0.8(lagger) | Transient voltage regulation(%):+20~-15 | |
Output voltage:400V/230V | Voltage settling time(s):≤1 | |
Output currency:36A | Steady state frequency regulation(%):≤±1 | |
Rated frequency:50Hz | Frequency fluctuation rate(%):≤±0.5 | |
Rated RPM:1500rpm | Transient frequency adjustment rate(%):+10~-7 | |
Fuel brand:(Standard) 0# light diesel oil (at room temperature) | Frequency stabilization time(S):≤3 | |
Overall size:1620*850*1580(L×W×H mm) | Oil consumption(100% loading):≤204g/kW·h | |
NET WEIGHT:610kg | Noise(LP7m):95dB(A) | |
★Diesel engine parameter: | ||
Brand:DCEC CUMMINS | Cooling mode:full-closed water-cooling | |
Model number:4B3.9-G | Supply oil type:direct injection | |
Rated power:24kw | Standby power:28kw | |
Cylinder number:4/L type | Governor type:Mechancial | |
Bore & Stroke:102*120 mm | Intake:Turbo Charge | |
Compression:16.5:1 | Loading capacity:110% | |
Starting mode:DC24V electric | RPM:1500rpm | |
Diesel engine size: 765mm × 582mm × 908mm | Net weight: 320KG | |
Coolant Intake Size: | Φ58mm | |
Coolant Outlet Size: | Φ45mm | |
Lubricant capacity: 11L | Coolant capacity:5L | |
★Alternator parameter: | ||
Brand:Kangwo | Indication of protection:IP23 | |
Model number:HQF-XN20(XN184H) | Connecting type: Three phase and 4 wires,“Y”type | |
Rated power:20KW | Regulating type:AVR(Automatic voltage regulator) | |
Rated voltage:400V/230V | Output frequency:50Hz | |
Insulation class:H grade | Power factor:COSΦ=0.8(lagger) |
★★30KW CUMMINS diesel gensets specification★★ | ||
★Diesel gensets parameter: | ||
Model number:KWHQ30GF | Steady state voltage regulation(%):≤±1 | |
Output power:30KW | Voltage fluctuation rate(%):≤±0.5 | |
Pwer factor:COSΦ=0.8(lagger) | Transient voltage regulation(%):+20~-15 | |
Output voltage:400V/230V | Voltage settling time(s):≤1 | |
Output currency:54A | Steady state frequency regulation(%):≤±1 | |
Rated frequency:50Hz | Frequency fluctuation rate(%):≤±0.5 | |
Rated RPM:1500rpm | Transient frequency adjustment rate(%):+10~-7 | |
Fuel brand:(Standard) 0# light diesel oil (at room temperature) | Frequency stabilization time(S):≤3 | |
Overall size:1620*610*1380(L×W×H mm) | Oil consumption(100% loading):≤204g/kW·h | |
NET WEIGHT:610kg | Noise(LP7m):95dB(A) | |
★Diesel engine parameter: | ||
Brand:DCEC CUMMINS | Cooling mode:full-closed water-cooling | |
Model number:4BT3.9-G1 | Supply oil type:direct injection | |
Rated power:36kw | Standby power:40kw | |
Cylinder number:4/L type | Governor type:Mechancial | |
Diesel engine displacement: | 3.9 Liters | |
Bore & Stroke:102*120 mm | Intake:Turbo Charge | |
Compression:16.5:1 | Loading capacity:110% | |
Starting mode:DC24V electric | RPM:1500rpm | |
Lubricant capacity: | 11 Liters | |
Coolant Capacity: | 8 Liters(Engine Only) | |
Wet weight: | 320KG | |
Coolant Intake Size: | Φ58mm | |
Coolant Outlet Size: | Φ45mm | |
★Alternator parameter: | ||
Brand:Kangwo | Indication of protection:IP23 | |
Model number:HQF-XN30(XN184H) | Connecting type: Three phase and 4 wires,“Y”type | |
Rated power:30KW | Regulating type:AVR(Automatic voltage regulator) | |
Rated voltage:400V/230V | Output frequency:50Hz | |
Insulation class:H grade | Power factor:COSΦ=0.8(lagger) |
★★40KW CUMMINS diesel gensets specification★★ | ||
★Diesel gensets parameter: | ||
Model number:KWHQ40GF | Steady state voltage regulation(%):≤±1 | |
Output power:40KW | Voltage fluctuation rate(%):≤±0.5 | |
Pwer factor:COSΦ=0.8(lagger) | Transient voltage regulation(%):+20~-15 | |
Output voltage:400V/230V | Voltage settling time(s):≤1 | |
Output currency:72A | Steady state frequency regulation(%):≤±1 | |
Rated frequency:50Hz | Frequency fluctuation rate(%):≤±0.5 | |
Rated RPM:1500rpm | Transient frequency adjustment rate(%):+10~-7 | |
Fuel brand:(Standard) 0# light diesel oil (at room temperature) | Frequency stabilization time(S):≤3 | |
Overall size:1760*710*1400(L×W×H mm) | Oil consumption(100% loading):≤204g/kW·h | |
NET WEIGHT:850kg | Noise(LP7m):95dB(A) | |
★Diesel engine parameter: | ||
Brand:DCEC CUMMINS | Cooling mode:full-closed water-cooling | |
Model number:4BTA3.9-G2 | Supply oil type:direct injection | |
Rated power:50kw | Standby power:50kw | |
Displacement: | 3.9 Liters | |
Cylinder number:4/L type | Governor type:Electronic Speed Regulation | |
Bore & Stroke:102*120 mm | Intake:Turbo Charge | |
Compression:16.5:1 | Loading capacity:110% | |
Starting mode:DC24V electric | RPM:1500rpm | |
Wet weight: | 340KG | |
Lubricant capacity: | 11 Liters | |
Coolant Capacity: | 8 Liters(Engine Only) | |
Coolant Intake Size: | Φ58mm | |
Coolant Outlet Size: | Φ45mm | |
★Alternator parameter: | ||
Brand:Kangwo | Indication of protection:IP23 | |
Model number:HQF-XN40 | Connecting type: Three phase and 4 wires,“Y”type | |
Rated power:40KW | Regulating type:AVR(Automatic voltage regulator) | |
Rated voltage:400V/230V | Output frequency:50Hz | |
Insulation class:H grade | Power factor:COSΦ=0.8(lagger) |
★★50KW CUMMINS diesel gensets specification★★ | ||
★Diesel gensets parameter: | ||
Model number:KWHQ50GF | Steady state voltage regulation(%):≤±1 | |
Output power:50KW | Voltage fluctuation rate(%):≤±0.5 | |
Pwer factor:COSΦ=0.8(lagger) | Transient voltage regulation(%):+20~-15 | |
Output voltage:400V/230V | Voltage settling time(s):≤1 | |
Output currency:90A | Steady state frequency regulation(%):≤±1 | |
Rated frequency:50Hz | Frequency fluctuation rate(%):≤±0.5 | |
Rated RPM:1500rpm | Transient frequency adjustment rate(%):+10~-7 | |
Fuel brand:(Standard) 0# light diesel oil (at room temperature) | Frequency stabilization time(S):≤3 | |
Overall size:1850*850*1700(L×W×H mm) | Oil consumption(100% loading):≤204g/kW·h | |
NET WEIGHT:850kg | Noise(LP7m):95dB(A) | |
★Diesel engine parameter: | ||
Brand:DCEC CUMMINS | Cooling mode:full-closed water-cooling | |
Model number:4BTA3.9-G2 | Supply oil type:direct injection | |
Rated power:50kw | Standby power:50kw | |
Displacement: | 3.9 Liters | |
Cylinder number:4/L type | Governor type:Electronic Speed Regulation | |
Bore & Stroke:102*120 mm | Intake:Turbo Charge | |
Compression:16.5:1 | Loading capacity:110% | |
Starting mode:DC24V electric | RPM:1500rpm | |
Wet weight: | 340KG | |
Lubricant capacity: | 11 Liters | |
Coolant Capacity: | 8 Liters(Engine Only) | |
Coolant Intake Size: | Φ58mm | |
Coolant Outlet Size: | Φ45mm | |
★Alternator parameter: | ||
Brand:Kangwo | Indication of protection:IP23 | |
Model number:HQF-XN50 | Connecting type: Three phase and 4 wires,“Y”type | |
Rated power:50KW | Regulating type:AVR(Automatic voltage regulator) | |
Rated voltage:400V/230V | Output frequency:50Hz | |
Insulation class:H grade | Power factor:COSΦ=0.8(lagger) |
★★75KW CUMMINS diesel gensets specification★★ | ||
★Diesel gensets parameter: | ||
Model number:KWHQ75GF | Steady state voltage regulation(%):≤±1 | |
Output power:75KW | Voltage fluctuation rate(%):≤±0.5 | |
Pwer factor:COSΦ=0.8(lagger) | Transient voltage regulation(%):+20~-15 | |
Output voltage:400V/230V | Voltage settling time(s):≤1 | |
Output currency:135A | Steady state frequency regulation(%):≤±1 | |
Rated frequency:50Hz | Frequency fluctuation rate(%):≤±0.5 | |
Rated RPM:1500rpm | Transient frequency adjustment rate(%):+10~-7 | |
Fuel brand:(Standard) 0# light diesel oil (at room temperature) | Frequency stabilization time(S):≤3 | |
Overall size:2150*830*1480(L×W×H mm) | Oil consumption(100% loading):≤204g/kW·h | |
NET WEIGHT:950kg | Noise(LP7m):95dB(A) | |
★Diesel engine parameter: | ||
Brand:DCEC CUMMINS | Cooling mode:full-closed water-cooling | |
Model number:6BT5.9-G1 | Supply oil type:direct injection | |
Rated power:86kw | Standby power:92kw | |
Displacement: | 5.9 Liters | |
Cylinder number:6/L type | Governor type:Mechancial | |
Bore & Stroke:102*120 mm | Intake:Turbo Charge | |
Compression:17.5:1 | Loading capacity:110% | |
Wet weight: | 425KG | |
Lubricant capacity: | 16 Liters | |
Coolant Capacity: | 11 Liters(Engine Only) | |
Coolant Intake Size: | Φ58mm | |
Coolant Outlet Size: | Φ45mm | |
Starting mode:DC24V electric | RPM:1500rpm | |
★Alternator parameter: | ||
Brand:Kangwo | Indication of protection:IP23 | |
Model number:HQF-XN75(XN274CS) | Connecting type: Three phase and 4 wires,“Y”type | |
Rated power:75KW | Regulating type:AVR(Automatic voltage regulator) | |
Rated voltage:400V/230V | Output frequency:50Hz | |
Insulation class:H grade | Power factor:COSΦ=0.8(lagger) |
★★100KW CUMMINS diesel gensets specification★★ | ||
★Diesel gensets parameter: | ||
Model number:KWHQ100GF | Steady state voltage regulation(%):≤±1 | |
Output power:100KW | Voltage fluctuation rate(%):≤±0.5 | |
Pwer factor:COSΦ=0.8(lagger) | Transient voltage regulation(%):+20~-15 | |
Output voltage:400V/230V | Voltage settling time(s):≤1 | |
Output currency:180A | Steady state frequency regulation(%):≤±1 | |
Rated frequency:50Hz | Frequency fluctuation rate(%):≤±0.5 | |
Rated RPM:1500rpm | Transient frequency adjustment rate(%):+10~-7 | |
Fuel brand:(Standard) 0# light diesel oil (at room temperature) | Frequency stabilization time(S):≤3 | |
Overall size:2250*920*1600(L×W×H mm) | Oil consumption(100% loading):≤205g/kW·h | |
NET WEIGHT:1250kg | Noise(LP7m):95dB(A) | |
★Diesel engine parameter: | ||
Brand:DCEC CUMMINS | Cooling mode:full-closed water-cooling | |
Model number:6BTA5.9-G2 | Supply oil type:direct injection | |
Rated power:106kw | Standby power:112kw | |
Cylinder number:6/L type | Governor type:Electronic Speed Regulation | |
Bore & Stroke:102*120 mm | Intake:Turbo Charge | |
Compression:17.5:1 | Loading capacity:110% | |
Wet weight: | 450KG | |
Lubricant capacity: | 16 Liters | |
Coolant Capacity: | 14 Liters(Engine Only) | |
Coolant Intake Size: | Φ58mm | |
Coolant Outlet Size: | Φ45mm | |
Starting mode:DC24V electric | RPM:1500rpm | |
★Alternator parameter: | ||
Brand:Kangwo | Indication of protection:IP23 | |
Model number:HQF-XN100 | Connecting type: Three phase and 4 wires,“Y”type | |
Rated power:100KW | Regulating type:AVR(Automatic voltage regulator) | |
Rated voltage:400V/230V | Output frequency:50Hz | |
Insulation class:H grade | Power factor:COSΦ=0.8(lagger) |
★★120KW CUMMINS diesel gensets specification★★ | ||
★Diesel gensets parameter: | ||
Model number:KWHQ120GF | Steady state voltage regulation(%):≤±1 | |
Output power:120KW | Voltage fluctuation rate(%):≤±0.5 | |
Pwer factor:COSΦ=0.8(lagger) | Transient voltage regulation(%):+20~-15 | |
Output voltage:400V/230V | Voltage settling time(s):≤1 | |
Output currency:216A | Steady state frequency regulation(%):≤±1 | |
Rated frequency:50Hz | Frequency fluctuation rate(%):≤±0.5 | |
Rated RPM:1500rpm | Transient frequency adjustment rate(%):+10~-7 | |
Fuel brand:(Standard) 0# light diesel oil (at room temperature) | Frequency stabilization time(S):≤3 | |
Overall size:2250*920*1600(L×W×H mm) | Oil consumption(100% loading):≤205g/kW·h | |
NET WEIGHT:1350kg | Noise(LP7m):95dB(A) | |
★Diesel engine parameter: | ||
Brand:DCEC CUMMINS | Cooling mode:full-closed water-cooling | |
Model number:6BTAA5.9-G2 | Supply oil type:direct injection | |
Rated power:120kw | Standby power:130kw | |
Displacement:5.9 Liters | ||
Fuel Injection Pump: | PN Injection Pump | |
Governor: | Electrical Governor RSV Mechanical Governor | |
Cylinder number:6/L type | Governor type:Electronic Speed Regulation | |
Bore & Stroke:102*120 mm | Intake:Turbo Charge | |
Compression:17.5:1 | Loading capacity:110% | |
Wet weight: | 425KG | |
Lubricant capacity: | 16 Liters | |
Coolant Capacity: | 11 Liters(Engine Only) | |
Coolant Intake Size: | Φ58mm | |
Coolant Outlet Size: | Φ45mm | |
Starting mode:DC24V electric | RPM:1500rpm | |
★Alternator parameter: | ||
Brand:Kangwo | Indication of protection:IP23 | |
Model number:HQF-XN120 | Connecting type: Three phase and 4 wires,“Y”type | |
Rated power:120KW | Regulating type:AVR(Automatic voltage regulator) | |
Rated voltage:400V/230V | Output frequency:50Hz | |
Insulation class:H grade | Power factor:COSΦ=0.8(lagger) |
Новинки товаров от производителей по оптовым ценам