Конкурентоспособная цена 5 ква 24 В 1 кВт 48 в 4000 Вт Солнечный инвертор Mppt зарядное устройство 220 3000 12 до вольт

Сохранить в закладки 1600671087554:


Цена:18 650,98 ₽ - 23 313,72 ₽*

Количество:

  • В избранное

Описание и отзывы

Характеристики





Feature


1. High frequency design, high power density, small size, high efficiency, low no-load loss.

2. Built-in MPPT solar charge controller optional.

3. Pure sine wave output,any types of loads adaptable.

4. Battery charge and discharge voltage parameters adjustable,suitable for different types of

batteries,can prolong the life of the battery and improve system performance.

5. Three working modes adjustable:AC first,Battery first,PV first.

6. Output voltage/frequency adjustable function,adapt to different grid environment.

7. Extra wide voltage and frequency input range, support mains or generator.

8. LED+LCD display, easy operation and data checking,can set each function and data directly.

9. Multi-protection function(overload,over temperature,short circuit protection and so on).

10. RS485 communication port/APP optional.


Highlight




Product Detail




Specification


Model:HP PRO-T
32224
50248
Rated Power
3200W
5000W
Battery Voltage
24VDC
4SVDC
Product Size (L*W*Hmm)
420x290x110
460x304x110
Package Size (L*W*Hmm)
486x370x198
526x384x198
N.W (Kg)
8.5
9.5
G.W (Kg)
9.5
10.5
Installation Method
Wall-Mounted
PV
Charging Mode
MPPT
Rated PV input voltage
360VDC
MPPT tracking voltage range
120V-450V
Max PV Input Voltage Voc (At the lowest temperature)
500V
PV Array Maximum Power
4000W
6000W
MPPT tracking channels (input channels)
1
Input
DC Input Voltage Range
21-30VDC
42-60VDC
Rated AC input voltage
220VAC / 230VAC /240VAC
AC Input Voltage Range
170VAC-280VAC (UPS mode) / 120VAC-280VAC (INVmode)
AC Input Frequency Range
45Hz~55Hz (50Hz), 55Hz~65Hz (60Hz)
Output
Output efficiency(Battery/PV Mode)
94% (Peakvalue)
Output Voltage(Battery/PV Mode)
220VAC+2% /230VAC±2% /240VAC±2%
Output Frequency(Battery/PV Mode)
50Hz±0.5or60Hz±0.5 (INVmode)
Output Wave(Battery/PV Mode)
Pure Sine Wave
Efficiency(AC Mode)
299%
Output Voltage(AC Mode)
Follow input
Output Frequency(AC Mode)
Follow input
Output waveform distortion Battery/PV Mode)
≤3%(Linear load)
No load loss(Battery Mode)
≤1% rated power
No load loss(AC Mode)
≤0.5% rated power(charger does not work in AC mode)
Battery
Battery Type
VRLA Battery
Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery
Charging and discharging parameters of different types of batteries can be customized according to user requirements (charging and
discharging parameters of different types of batteries can be set through the operation panel)
Max AC Charging Current
60A
60A
Max PV Charging Current
100A
100A
Maximum charging current (mains + PV)
100A
100A
Charging method
Three-stage (constant current, constant voltage, floating charge)
Protection
Battery low voltage alarm
Battery undervoltage protection value+0.5V(Single battery voltage)
Battery low voltage protection
Factory default: 10.5V(Single battery voltage)
Battery overvoltage alarm
Constant charge voltage+0.8V(Single battery voltage)
Battery over voltage protection
Factory default: 17V(Single battery voltage)
Battery over voltage recovery voltage
Battery overvoltage protection value-1V(Single battery voltage)
Overload power protection
Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection
Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection
>90°C(Shut down output)
Working Mode
Mains pnority/Solar pnority/Battery priority(Can be set)
Transfer Time
≤4ms
Display
LCD+LED
Thermal method
Cooling fan in intelligent control
Communication(Optional)
RS485/APP(WIFI monitoring or GPRS monitoring)


Wiring Diagram




1. We offer 3 optional working modes (transfer time≤4ms):
1) AC priority mode (d0)

. When the mains power is normal , on the one hand, the mains power charges the battery ; on the other hand, only the mains power supplies power to the load;
. When the mains power is abnormal, the inverter will switch to the battery mode, and the battery will supply power to the load .


2) PV priority mode (d1)
. When the solar is normal, if the solar power is greater than the power of the load, the load is completely powered by solar, when the solar power is less than the power of the load, the insufficient part is supplemented by the battery, and the solar and the battery supply power to the load together. If the battery is low volage due to the load, then the inverter will turn to the AC mode for power supply, and the solar will only charge the battery;
. When the solar is abormal, the inverter will directly switch to the AC mode for power supply, and the mains power will charge the battery.

3) Battery priority mode (d2)
. When the inverter has no low-voltage battery alarm, even if the mains power input is normal, the inverter will switch to the battery mode, and the battery will supply power to the load.
. When the battery is low voltage (i.e. the voltage of a conventional single battery is 11vdc) and the mains power input is normal, the inverter will switch to the AC mode and the mains power will supply power to the load completely, while the solar energy will charge the battery but the mains power does not charge the battery.


Application




Packing & Delivery




Package
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.
Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.


Payment
T/T
EXW
30% T/T in advance, balance paid before dispatch
FOB
CNF(CFR)
30% T/T in advance, balance paid against copy of B/L
CIF
L/C, D/A, D/P, Money Gram, Western Union, Paypal (Optional)









Company Profile






Guangdong Xindun Power Technology Co.,Ltd
Factory Location
Foshan,Guangdong,China
Product Range
solar inverter, hybrid inverter, ups, solar charge controller, solar generator, solar power system, mini solar dc system
Main Market
Africa, Middle East, Asia & South America. (Ukraine, Russia, Vietnam, Pakistan, Nigeria, Kenya, South Afriac, Ghana, Thailand, Philippines, etc.)
Factory
7000 Square Meters, 100+ workers
Department
R&D, Production, Sales, Marketing, Purchasing, QA, After-sale service department
Certificate
ISO 14001:2015, CE, IEC, etc.
Patent
Software Paten, Design Patent, Project Pantent














Похожие товары

Новые поступления

Новинки товаров от производителей по оптовым ценам