1. Pure sine wave output.
2. Low DC voltage, saving system cost.
3. Built-in PWM or MPPT charge controller.
4. AC charge current 0-45A adjustable.
5. Wide LCD screen, clearly and precisely shows icon data.
6. 100% imbalance loading design, 3 times peak power.
7. Setting different working modes based on variable usage requirements.
8. Various communication ports and Remote monitoring RS485/APP(WIFI/GPRS) (Optional)
3.2kw ~ 6.4kw solar inverter model:
8kw ~ 24kw solar inverter model:
32kw ~ 64kw solar inverter model:
80kw ~ 128kw solar inverter model:
150kw ~160kw solar inverter model:
Specification | ||||||||||||
Model: HDSX/HDSX-T | 32248/ 96/192 | 48248/ 96/192 | 56248/ 96/192 | 64248/ 96/192 | 80248/ 96/192 | 10348/ 96/192 | 12348/ 96/192 | 16396/ 192 | 20396/ 192 | 24396/ 192 | ||
Rated Power | 4KVA/ 3.2KW | 6KVA/ 4.8KW | 7KVA/ 5.6KW | 8KVA/ 6.4KW | 10KVA/ 8KW | 12.5KVA/ 10KW | 15KVA/ 12KW | 20KVA/ 16KW | 25KVA/ 20KW | 30KVA/24KW | ||
Peak Power(20ms) | 9.6KVA | 14.4KVA | 16.8KVA | 19.2KVA | 24KVA | 30KVA | 36KVA | 48KVA | 60KVA | 72KVA | ||
Start Motor | 3HP | 4HP | 4HP | 4HP | 5HP | 6HP | 7HP | 10HP | 10HP | 15HP | ||
Battery Voltage | 48/96/192VDC | 96/192VDC | ||||||||||
Built-in solar controller charging current (Optional) | PWM: 10A-60A(48V System); 50A/100A(96V System); 50A(192V System) MPPT: 10A-100A(48V System); 50A/100A(96V System) | PWM: 50A/100A(96V System); 50A/100A(192V System) MPPT: 50A/100A(96V System) | ||||||||||
Size(L*W*Hmm) | 565*300*775 | 725*365*1010 | ||||||||||
Packing Size(L*W*Hmm) | 625*360*895 | 785*425*1135 | ||||||||||
N.W.(kg) | 65 | 73 | 75 | 80 | 112 | 122 | 134 | 160 | 176 | 189 | ||
G.W.(kg)(Wooden Packing) | 78 | 86 | 88 | 93 | 136 | 146 | 158 | 184 | 200 | 213 | ||
Installation Method | Tower | |||||||||||
Technical Specifications | ||||||||||||
Model: HDSX | 323192 | 403192 | 483384 | 643384 | 803384 | 963384 | 1003384 | 1203384 | 1283384 | 1503384 | 1603384 | |
Rated Power | 40KVA/ 32KW | 50KVA/ 40KW | 60KVA/ 48KW | 80KVA/ 64KW | 100KVA/ 80KW | 120KVA/ 96KW | 125KVA/ 100KW | 150KVA/ 120KW | 160KVA/ 128KW | 190KVA/ 150KW | 200KVA/ 160KW | |
Peak Power(20ms) | 96KVA | 120KVA | 144KVA | 192KVA | 240KVA | 288KVA | 300KVA | 360KVA | 384KVA | 450KVA | 480KVA | |
Start Motor | 15HP | 20HP | 25HP | 30HP | 40HP | 50HP | 50HP | 60HP | 60HP | 80HP | 80HP | |
Battery Voltage | 192VDC | 384VDC | ||||||||||
Built-in solar controller charging current (Optional) | PWM: 100A-200A(192V&384V System) MPPT: 50A/100A(192V&384V System) | PWM: 100A-200A / MPPT: 50A/100A | ||||||||||
Size(L*W*Hmm) | 720*575*1275 | 875*720*1380 | 1123*900*1605 | |||||||||
Packing Size(L*W*Hmm) | 785*640*1400 | 980*825*1560 | 1185*960*1750 | |||||||||
N.W.(kg) | 240 | 260 | 290 | 308 | 512 | 542 | 552 | 612 | 642 | 705 | 755 | |
G.W.(kg)(Wooden Packing) | 273 | 293 | 323 | 341 | 552 | 582 | 592 | 652 | 692 | 755 | 805 | |
Installation Method | Tower | |||||||||||
Parameter | ||||||||||||
Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) | ||||||||||
AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | |||||||||||
AC Input Frequency Range | 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) | |||||||||||
Max AC charging current | 0-45A(Depending on the model) | |||||||||||
AC charging method | Three-stage (constant current, constant voltage, floating charge) | |||||||||||
Phase | 3/N/PE | |||||||||||
Output | Efficiency(Battery Mode) | ≥85% | ||||||||||
Output Voltage(Battery Mode) | 380Vac/400Vac±2%(customized 190Vac/200Vac) | |||||||||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | |||||||||||
Output Wave(Battery Mode) | Pure Sine Wave | |||||||||||
Output waveform distortion | Linear load≤3% | |||||||||||
Efficiency(AC Mode) | >99% | |||||||||||
Output Voltage(AC Mode) | Conforming to AC input | |||||||||||
Output Frequency(AC Mode) | Conforming to AC input | |||||||||||
No load loss(Battery Mode) | ≤2.5% rated power(4KVA-30KVA models);≤1% rated power(40KVA-200KVA models) | |||||||||||
No load loss(AC Mode) | ≤2%rated power( charger does not work in AC mode) | |||||||||||
No load loss(Energy saving Mode) | ≤10W | |||||||||||
Phase | 3/N/PE | |||||||||||
Battery Type | VRLA Battery | Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) | ||||||||||
Customize battery | Charging and discharging parameters of different types of batteries can be customized according to user requirements | |||||||||||
Protection | Battery undervoltage alarm/Battery undervoltage protection/Battery overvoltage alarm/Battery overvoltage protection/Battery overvoltage recovery voltage/Overload power protection/Inverter output short circuit protection/Temperature protection | |||||||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | ||||||||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | |||||||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | |||||||||||
Inside Solar controller (Optional) | Charging Mode | MPPT or PWM | ||||||||||
Charging current | PWM: 10A/20A/30A/40A/50A/60A(48V System); 50A/100A/150A/200A(96V/192V/384V System) 50A/100A(96V/192V/384V System) | |||||||||||
PV Input Voltage Range | PWM: 60V-88V(48V System); 120V-176V(96V System); 240V-352V(192V System); 480V-704V(384V System) MPPT: 60V-120V(48V System); 120V-240V(96V System); 240V-360V(192V System); 480V-640V(384V System) | |||||||||||
Max PV Input Voltage(Voc) (At the lowest temperature) | PWM: 100V(48V System); 200V(96V System); 400V(192V System); 750V(384V System) MPPT: 150V(48V System); 300V(96V System); 450V(192V System); 800V(384V System) | |||||||||||
PV Array Maximum Power | 48V System: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A) 16.8KW*2(150A)/22.4KW*2(200A)) / (MPPT: 11.2KW(50A)/11.2KW*2(100A)); 33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)) | |||||||||||
Standby loss | ≤3W | |||||||||||
Maximum conversion efficiency | >95% | |||||||||||
Working Mode | Battery First/AC First/Saving Energy Mode | |||||||||||
Transfer Time | ≤4ms | |||||||||||
Display | LCD | |||||||||||
Thermal method | Forced air cooling | |||||||||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) |
*Xindun power is from 300w~200kw, If you have any question, Please feel free to contact us.
Package
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.
Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.
A: Are your inverters pure sine wave output?
Q: A Yes, All are true pure sine wave.
A: What kind of output you can do?
Q: Normally we produce inverter with 110V 115V 120V 220V 230V 240V, 50/60Hz self-adaption. If you have special requirements, please tell us for engineer consulting.
A: What' s the difference between low frequency and high frequency inverter?
Q: Low frequency inverter has various protections, strong ability to adapt to the environment. more reliable, with voltage regulation.
A: What's the difference between pure sine wave inverter and modified sine wave inverter?
Q: Pure sine wave output inverter is just as good as the Public power grid. Even better. Low repaired rate, long lifespan, Without harmonic pollution, enviromental-friendly and appliances protected.
Modified sine wave output has a negative impact on appliances and can't load inductive load, such as air contition, refrigerator and etc. Certain motor control circuits don't like the modified wave.
A: What appliances your inverters can load?
Q: Our inverter can be used in household, Office, agricultural appliances and other inductive load such as refrigerator, air conditioner, water pump, etc.
A: Can you print our company logo on inverters, nameplates and packaging?
Q: Yes, we accept OEM orders.
A: How to choose a right inverter?
Q: Tell us your demand, then our sales will recommend a suitable inverter to you.
A: How to solve the technical problem?
Q: 24 hours after-service consultancy just for you and to make your problem to solveeasily.
A: Do I Need A Power Inverter?
Q: Actually, no. This is the only component of a solar energy system that is not absolutely required. However, if you don't use one, you will not have 220 or 230 volts AC and will have use battery power alone. This might be acceptable in a small RV or cabin, but most people want to use normal AC appliances.
A: What's The Difference Between 12, 24, And 48 Volt Inverters?
Q: This refers to the input voltage from the battery bank. The main consideration is that at higher voltages the current is less so that you can use smaller wires between your solar panel array and your battery bank. Of course, when you decide on a system voltage, the Solar Panels, Inverter, and Battery Bank all need to use the same voltage.
A: What to do if the product is broken?
Q: If any product is faulty, you can send the picture or video to us, we sill study it and supply the spare parts of PCB board free for after sale service.
Новинки товаров от производителей по оптовым ценам