Сохранить в закладки 1600918053535:
1 Product Application Conditions
1.1 Media requirements
Use medium: water
Medium water temperature: 0℃~50℃
Medium PH value: 6.5~8.5
Medium hardness: ≤25°dH
Solid impurity content in the medium: solid impurity diameter and length direction ≤ 0.1mm, and volume ratio ≤ 0.1%.
1.2 Use environment requirements
How to use: keep the axis horizontal
Altitude: <1000m
Operating environment temperature: 0℃~55℃ (no freezing phenomenon in the pipeline and water pump)
Use environment humidity ≤95%
1.3 Storage environment requirements
Storage ambient temperature: -20°C~60°C (no freezing in pipelines and pumps)
Storage environment humidity ≤95%
2. Product installation direction diagram
When the water pump is installed, the pump shaft must be in a horizontal position, and the pump shaft is allowed to be installed at an angle of ±5°. The installation of the water pump in the system should ensure that the pump cavity is filled with liquid so that the water pump can operate normally. Pipeline installation must be carried out according to the diagram, and the rubber pads should be well supported.
3. Start and stop of water pump
Start-up time: The start-up time of the water pump is less than 5s, that is, the time from power-on to maximum speed
Downtime: the pump stop time < 3s, that is, the time from when the pump is powered off to when it stops running
1. Basic parameters of the product
Maximum flow(m³/h):5.5 | Maximum head(m):45 | Voltage:AC 220V/50Hz |
Rated flow(m³/h):3.0 | Rated head(m):30 | Maximum input power:600W |
Design pressure:1.0MPa | Protection class:IP44 | Maximum speed:5000rpm |
Noise:<58dB(A)(Max flow) | Bare pump weight:9.2kg±5% | Self-priming height:≤8m |
Standby power consumption:≤10W | Inlet and outlet pipe diameter:DN25 | Steering: counterclockwise when viewed from the pump inlet |
2. Product application range
Pressurization of commercial water, groundwater intake for domestic use, and pressurization of domestic water supply.
3. Product certification
Products comply with CCC, GS (CE), EMC, RoHS, REACH, WRAS certification requirements.
4. Motor type
Motor type: permanent magnet synchronous motor | Enameled wire material: copper | Magnetic steel material: NdFeB |
DC cold state resistance of the motor at 20°C: 3.77±5%Ω | Insulation class: F |
5. Performance Curve