12V7Ah батарея 12 вольт свинцово кислотные батареи герметичные аккумуляторные глубокого цикла

Сохранить в закладки 1600918586409:


Цена:5,41 $*

Количество:

  • В избранное

Описание и отзывы

Характеристики



Products Description








Features:
12V monolithic AGM valve regulated sealed lead-acid battery. It has advantages including wide capacity range, multi-type, safety reliable seal, small internal impedance,low self-discharge, sealed and high efficient reaction, clean and environment protection,safe, clean, easy installation and so on.It is widely used in various fields of communication systems, power systems, uninterruptible power supply (UPS), solar systems,fire alarms and security systems.
• Operating temperature range: -15 ~ 45 ℃
• The design life is 5 years
• Using special polybasicled base alloy grid with high corrosion resistance and charge acceptance
• Using new special process sheet formula to improve the utilization of active material
• Using high quality superfine glass fiberliquid-suction battery technology to exceed 99% gas recombination rate
• High-strength ABS plastic battery slot and cover with features of compact structure, corrosion resistant, impact resistance and anti-vibration and so on
• Small internal impedance, excellent performance when high current discharge
• Low self-discharge, wide operating temperature range
• Using multiple sealing technologies to ensure no leakage, no acid mist escaping to keep safe and reliable
• Using strict production process, unit voltage balance is strong
• Free maintenance, without adding water rehydration
• The battery has full charged before leaving the factory, and transportation is safe systems, fire alarms and security systems


Details Images




> Silver plated copper terminal

> Good electrical conductivity,anti-corrosion and anti-corrosion




> Battery case is made from a Non-Conductive ABS plastic, Strong Resistance to Shock, Vibration, Chemicals, Weather and Heat.





Lead-acid Energy Storage Battery
Performance characteristics
1. Safety seal
During normal operation, the electrolyte will not leak out from the battery terminals or housing.
2. No free acid
The special liquid-absorbing partition keeps the acid inside. There is no free acid inside the battery, so the battery can be placed at any position.
3. Vent system
After the internal pressure of the battery exceeds the normal level, VRLA (Valve-Regulated LeadAcid Battery) battery will release excess gas and automatically reseal to ensure that there is no excess gas in the battery.
4. Simple maintenance
Since the unique gas composite system converts the gas into water, do not add water in the process of using the battery.
5. Long service life
The lead-calcium alloy fence with anti-corrosion structure is adopted, and the battery can be used for floating charge for 10-15 years.
6. Stable quality and high reliability
With advanced production technology and strict quality control system, the battery has stable quality and reliable performance. The voltage, capacity and sealing shall be 100% inspected on the line.





Product Paramenters


12V 7AH
Size
151*65*95
Application
marine, yacht, camping car, solar , storage, golf cart etc.
Function
Storage Energy
Feature
long lifespan quality
Usage
off grid solar system
Type
VRLA Battery




Application


RV Power Supply
Golf car
Water Working Power Supply


Transport
Communication base station
Solar Energy Storage



Widely use
* Automatic office system.
* Solar/Wind Power System.
* Radio communication system.
* Traffic and navigation signal lamp.
* Aviation, spaceflight, and power storage.
* Computer, uninterrupted power source (UPS).
* Emergency lighting and car/ship starting system.
* Portable electric appliances and mining system.
* Golf Car, wheelchair,electric bike, electric car etc.
* Fire fighting, safety device, and alarm monitoring.
* Power transmission and transformer station, switch control, and accident lighting.
* Telephone switchboard, electric equipments,medical equipments, instruments, and meters.




Warnings:
- Matrix series batteries have acid in the case and are fully charged before leaving factory. Do not attempt to dismantle the battery, if accidental skin/eye contact is made with electrolyte, seek medical advice immediately.
- Do not use a new battery with an old one.
- Do not use the battery in sealed container.
- Each battery should have detailed record including the ex-factory date, installing date and using record.
- Check the connection of wire in a fixed interval (once a year). If there is any looseness should tighten the wire.
- Wipe the surface of the battery with soft cloth in a fixed interval (once three months) and always keep the battery clean.
- Avoid using any kind of organic solvents for cleaning the surface of the battery.


Company Profile




Workflow




QUALITY CONTROL SYSTEM
1. Strict quality requirement for product
2. Responsible and wholehearted attitude to the work
3. Guidance from professional technological engineers
4. First-Class advanced equipment for production & testing
5. Precision measurement method during the production process


Certifications




Transport Packaging




FAQ








Похожие товары

Новые поступления

Новинки товаров от производителей по оптовым ценам