Сохранить в закладки 1601049386688:
New Energy EVI DC Inverter Heat Pump Water Heater Air cooled Modular Chiller
The air cooled heat pump modular chiller is a central air conditioning unit that uses air as its cooling and heating source and water as the heat transfer medium. The unit can form a centralized air conditioning system together with FCU and AHU for cooling in summer and heating in winter.
King series air cooled heat pump units employ a modular design, and include 65 kW and 130 kW modules. Up to 16 modules can be connected in parallel to form a combination product from 65 kW to 2,080 kW.
Environment-friendly
Energy-efficient
Excellent design
Features
High performance heat exchanger
High-efficiency low-noise fan, working with energy-saving motor
Smart control
Micro PC control board, intelligent and real-time adjustment
The micro PC control board features product operation control, safety protection, and
many other functions. Among them, the high-speed processing chip can quickly obtain
the operating parameters of the host system, and deliver control instructions in time to
realize rapid processing, implement smart control of the unit, and ensure the stable
operation of the unit.
Heat Pumps in Action: Various Application Scenarios
Model | YC-025TA1 | YC-050TA1 | YC-075TA1 | YC-120TA1 | YC-170TA1 | YC-220TA1 |
Power Supply | 380-415V/3/50Hz | |||||
Heating Capacity at Air 27°C/24°C, Water 27°C in, 29°C out | ||||||
Heating Capacity kW) | 25 | 50 | 70 | 120 | 170 | 220 |
Power Input (kW) | 4.2 | 8.4 | 11.7 | 20.1 | 28.6 | 37.6 |
COP | 5.91 | 5.95 | 5.96 | 5.98 | 5.95 | 5.85 |
Heating Capacity at Air 15°C/12°C,Water 26°C in, 28°C out | ||||||
Heating Capacity (kW) | 20 | 42 | 60 | 100 | 140 | 185 |
Power Input (kW) | 4.1 | 8.6 | 12.3 | 20.4 | 28.9 | 38.6 |
COP | 4.86 | 4.88 | 4.89 | 4.89 | 4.85 | 4.79 |
Cooling Capacity at Air 35°C/24°C,Water 29°C in, 27°C out | ||||||
Cooling Capacity (kW) | 18 | 36 | 55 | 85 | 120 | 160 |
Power Input (kW) | 5.3 | 10.5 | 15.9 | 24.6 | 35.2 | 47.6 |
EER | 3.39 | 3.42 | 3.45 | 3.45 | 3.41 | 3.36 |
Max Power Input (KW) | 6.9 | 13.2 | 20.1 | 29.1 | 48.5 | 67.2 |
Max Current (A) | 12.3 | 23.5 | 35.9 | 52.2 | 87.0 | 121.1 |
Refrigerant | R410A | |||||
Heat Exchanger | Titanium | |||||
Expansion Valve | Electronic | |||||
Air Flow Directicn | Vertical | |||||
Working temperature range (°C) | -15~43 | |||||
Water connection(mm) | 50 | 65 | 65 | 75 | 90 | 110 |
Water Flow Volume (m'/h) | 10 | 20 | 30 | 50 | 70 | 85 |
Noise (dB(A)) | <57 | <59 | <62 | <66 | <66 | <70 |
Net Weight (kg) | 120 | 250 | 450 | 760 | 900 | 1200 |
Net Dimensions(L*W*H) (mm) | 765*691*1055 | 14164752*1055 | 1250*1076*1870 | 2150*1078*2258 | 2150*1078*2258 | 2150*1078*2258 |
The Benefits of Heat Pumps For Bussiness
For every kWh of electricity consumed to power it, a heat pump produces roughly 4 kWh of energy, making them 300–400% more efficient than electric heating alone.
There is little question that large savings may be gained, even if the cost of installing something like an Air Source Heat Pump would vary depending on the size and complexity of the business facilities.
With MODBUS Communication
The heat pump system can be integrated with a commercial building management system thanks to the MODBUS adapter. Consequently, a variety of operating parameters, such as operating modes, flow, and room temperature, can be gathered and monitored. The output of the air-to-water heat pump can be instantly adjusted in accordance with the ongoing heat demand while taking the building specifications into consideration.
![RSX8.png]()
Wide Range Of Applications
The heating and cooling needs of various buildings, including villas, homes, industries, hotels, hospitals, spas, sauna facilities,greenhouses, flower gardens, farms, etc., might be satisfied by these EVI low-temperature heat pumps.
Outstanding Reliability
Fast cooling, heating and precise temperature control and durable construction, Anti-corrosion treatment as optional, Reliable scroll compressor, Multi-protection design.
High Reliability
The multiple operation protection feature safeguards the heat pump against voltage fluctuations, overheating, and other electrical faults, prolonging its lifespan and enhancing operational safety.
The alternative cycle duty and defrosting operation enables the heat pump to adjust its operating mode based on load requirements, ensuring optimal performance and energy efficiency.
Additionally, the anti-corrosion protection prevents damage from corrosive elements, enhancing the durability and longevity of the heat pump.
Convenient Usage
Comfort
The multiple silence modes provide users with flexible control over the sound emitted by the heat pumps. Whether it is for the comfort of customers in a hotel room or minimizing disturbance in a working environment, the YC series heat pump allows users to choose the appropriate noise level that suits their unique needs. Moreover, the special attention given to sound reduction ensures that the heat pumps operate at a low noise level, minimizing needless disturbance and making them ideal for noise-sensitive commercial applications.
Application Solutions
Office Complexes
Residential Apartments
Hotels & Shopping Malls
Other Applications
Our product
New Energy EVI DC Inverter Heat Pump Water Heater Air cooled Modular Chiller
Are you Factory ?
Our factory is located in Taizhou City, Jiangsu Province. The company is committed to terminal and integrated solutions for heat pump heating, air energy and hot water, central air conditioning, modular units, fan panels, etc. The company covers an area of 250 mu, with a building area of 68000 square meters, and has six modern electrical flow production lines. Each line produces 50 sets per shift, with a cumulative daily output of 150-200 sets.
The enterprise has passed the certification of IS09001 IS014001 GB/T28001 three systems, and has the comprehensive of - 25 ℃ ultra-low temperature national heat pump. At the same time, it is OEM for domestic and international first-tier brands.
Can you make samples?
We can make samples for you, but they are not free. You should bear the freight. However, if you order large goods later, we will refund you part of the cost of the sample higher than the price of the large goods.
Can you design for free ?
We have special designers who can help you design drawings for free, as long as you tell us your needs.
How to contact us ?
Henan Shangfeng Hvac Engineering Co., Ltd.(registered trademark: TX) is located in Taixing City, Jiangsu Province. The company is committed to heat pump heating, air energy hot water, central air conditioning, terminal and integrated application solutions .
Новинки товаров от производителей по оптовым ценам