Лидер продаж PV солнечный формованный корпус автоматический выключатель DC1000V 1500V 250A 320A 2P/3P MCCB

Сохранить в закладки 1601173421579:


Цена:1 940,78 ₽ - 9 111,79 ₽*

Количество:

  • В избранное

Описание и отзывы

Характеристики



Product Description


 _01.jpg_02.jpg_03.jpg_04.jpg_05.jpg_06.jpg_07.jpg_08.jpg


 































































































ModelMGM1DC-630HU
Number of poles23
Rated operational voltage Ue (V)DC250/500DC750/1000DC1250/1500DC1250/1500
Rated insulation voltage Ui (V)DC1500
Rated impulse withstand voltage Uimp (kV)12
Rated current In (A)500,630
Rated limit short-circuit capacity lcu(kA)H type70402020(2-pole string)
40(3-pole string)
R type85604040(2-pole string)
50(3-pole string)
Rated operating short-circuit breaking capacity lcs (kA)Ics=100%
ConnectionUp in, down out/down in, up out (2P, 320/3P)  Down in, down out/up in, up out (3P)
Utilization category 
Does it have isolation function 
Operating ambient temperature 
Mechanical lifespan (times)5000
Electrical lifespan (times)10001000700500
Compliant with standardsIEC/EN 60947-2 GB/T 14048.2
AnnexShunt excitation, auxiliary, alarm, manual operation, electric operation
AuthenticationCCC,CB,CE,TUV
Dimensions (length x width x height)250x124x165(2P)
250x182x165(3P)




Packaging & Shipping


 -_06.jpg





Company Information


 -_02-_12_05BACK TO HOME


 


 





FAQ


 1.How to test the function of a molded case circuit breaker to ensure its normal operation?
The testing of molded case circuit breakers mainly includes visual inspection, mechanical operation testing, electrical performance testing (such as insulation resistance and conductivity testing), as well as short circuit and thermal overload response testing, to ensure the reliability and safety of the circuit breaker. Be sure to take appropriate safety measures before operation.



2.How to reset the molded case circuit breaker after it trips?
To reset the tripped molded case circuit breaker, first confirm and resolve the cause of the trip. Then disconnect the power supply, fully turn the circuit breaker operating handle to the OFF position, and finally push the handle to the ON position to complete the reset. Ensure safe operation and consult a professional electrician if necessary.



3.Does the use of molded case circuit breakers require special safety measures?
When using molded case circuit breakers, it should be ensured that they are correctly installed and regularly maintained by professional personnel. Before operation, the power should be disconnected, appropriate personal protective equipment should be worn, the working principle of the equipment should be familiar, and measures should be taken to prevent unauthorized operation to ensure safe use.


 


4.What is the MOQ?
Usually we don't set MOQ, but the more, the cheaper. Besides, we are happy to make prototype or sample for clients to ensure quality standard.


.jpg




Похожие товары

Новые поступления

Новинки товаров от производителей по оптовым ценам