Корпус NAS 8 отсеков сетевой подключенный Серверный корпус для IPFS
440,00 $
Сохранить в закладки 1601201709979:
Endless Evolution | Flash-Like Performance | Cost Effectiveness |
• A single storage system meets the diverse needs of multiple services — including block, files, container, virtualization, and more — yielding higher storage utilization and lower Total Cost of Ownership (TCO). • Gateway-free active-active deployment for Storage Area Network (SAN) and Network-Attached Storage (NAS) supports smooth upgrade to geo-redundant Three-Data-Center (3DC)/Four-Data-Center (4DC) Disaster Recovery (DR) solutions. • The ransomware protection solution features Air Gap, secure snapshots, and End to End (E2E) encryption technologies to effectively defend against ransomware attacks. | • Innovative Smart Acceleration technology uses the dynamic adaptive data layout algorithm to accelerate hot data, resulting in two times higher performance than the preceding generation. • The system supports high-density snapshots while meeting high performance and reliability service requirements. • E2E Non-Volative Memory express (NVMe) architecture slashes latency to just 0.05 ms for a premium, all-flash experience. | • Data streams flow across generations — entry-level, mid-range, and high-end storage systems — requiring no extra costs.• The system supports up to 16 controllers, creating a linear increase in system performance to support service growth. • The Data Management Engine (DME) interconnects with Ansible and mainstream Information Technology (IT) service management platforms like ServiceNow, reducing Operations and Maintenance (O&M) costs. |
Model | OceanStor 5310 | OceanStor 5510 | OceanStor 5610 | |||
Hardware Specifications | ||||||
Maximum Number of Controllers | 16 | 16 | 16 | |||
Maximum Cache (Dual Controllers, Grows with the Expansion of Controllers) | 128 GB to 2 TB | 384 GB to 4 TB | 768 GB to 8 TB | |||
Supported Storage Protocols | FC, iSCSI, NFS, CIFS, FC-NVMe, NVMe over RoCE, FTP*, HTTP*, NDMP, S3* | FC, iSCSI, NFS, CIFS, FC-NVMe, NVMe over RoCE, FTP*, HTTP*, NDMP, S3* | FC, iSCSI, NFS, CIFS, FC-NVMe, NVMe over RoCE, FTP*, HTTP*, NDMP, S3* | |||
Front-End Channel Port Types | 8/16/32 Gbps FC/FC-NVMe, 1/10/25/40/100 Gbps Ethernet, 25 Gbps NVMe over RoCE | 8/16/32 Gbps FC/FC-NVMe, 1/10/25/40/100 Gbps Ethernet, 25 Gbps NVMe over RoCE | 8/16/32 Gbps FC/FC-NVMe, 1/10/25/40/100 Gbps Ethernet, 25 Gbps NVMe over RoCE | |||
Back-End Channel Port Types | 100 Gbps RDMA/SAS 3.0 | 100 Gbps RDMA/SAS 3.0 | 100 Gbps RDMA/SAS 3.0 | |||
Maximum Number ofHot-Swappable I/O Modules per Controller Enclosure | 6 | 12 | 12 | |||
Maximum Number of Front-End Host Ports per Controller Enclosure | 40 | 48 | 48 | |||
Disk Types | NVMe TLC SSD, SAS TLC SSD, SAS, NL-SAS | NVMe TLC SSD, SAS TLC SSD, SAS, NL-SAS | NVMe TLC SSD, SAS TLC SSD, SAS, NL-SAS | |||
Software Specifications | ||||||
RAID Levels | RAID 10*, RAID 5, RAID 6 and RAID-TP (tolerating simultaneous failure of three disks) | RAID 10*, RAID 5, RAID 6 and RAID-TP (tolerating simultaneous failure of three disks) | RAID 10*, RAID 5, RAID 6 and RAID-TP (tolerating simultaneous failure of three disks) | |||
Value-Added Software | SmartAcceleration, SmartThin, SmartQuota, SmartMulti-Tenant, SmartQoS, SmartVirtualization, SmartMigration, SmartCompression, SmartDedupe, SmartMigration for NAS, SmartMobility, HyperSnap, HyperReplication, HyperClone, HyperMetro, HyperCDP, HyperLock, HyperDetect, HyperEncryption, HyperLink*, CloudVxLAN, CloudBackup* | SmartAcceleration, SmartThin, SmartQuota, SmartMulti-Tenant, SmartQoS, SmartVirtualization, SmartMigration, SmartCompression, SmartDedupe, SmartMigration for NAS, SmartMobility, HyperSnap, HyperReplication, HyperClone, HyperMetro, HyperCDP, HyperLock, HyperDetect, HyperEncryption, HyperLink*, CloudVxLAN, CloudBackup* | SmartAcceleration, SmartThin, SmartQuota, SmartMulti-Tenant, SmartQoS, SmartVirtualization, SmartMigration, SmartCompression, SmartDedupe, SmartMigration for NAS, SmartMobility, HyperSnap, HyperReplication, HyperClone, HyperMetro, HyperCDP, HyperLock, HyperDetect, HyperEncryption, HyperLink*, CloudVxLAN, CloudBackup* | |||
Storage Management Software | Device Manager | UltraPath | DME IQ | |||
Electrical Specifications | ||||||
Power Supply | 100V to 240V AC±10%, 192V to 288V DC, -38.4V to -75V DC | 100V to 240V AC±10%, 192V to 288V DC, -38.4V to -75V DC | 200V to 240V AC±10%, 192V to 288V DC | |||
Dimensions (H x W x D) | 2.5-inch controller enclosure: 86.1 mm x 447 mm x 520 mm 3.5-inch controller enclosure: 86.1 mm x 447 mm x 600 mm NVMe controller enclosure*:86.1 mm × 447 mm × 620 mm | 2.5-inch controller enclosure: 86.1 mm x 447 mm x 820 mm 3.5-inch controller enclosure: 86.1 mm x 447 mm x 900 mm NVMe controller enclosure*: 86.1 mm x 447 mm x 920 mm | 2.5-inch controller enclosure: 86.1 mm x 447 mm x 820 mm 3.5-inch controller enclosure: 86.1 mm x 447 mm x 900 mm NVMe controller enclosure*: 86.1 mm x 447 mm x 920 mm | |||
SAS disk enclosure: 86.1 mm × 447 mm × 410 mm NVMe disk enclosure*: 86.1 mm × 447 mm × 620 mm NL-SAS disk enclosure: 175 mm x 447 mm x 488 mm | SAS disk enclosure: 86.1 mm × 447 mm × 410 mm NVMe disk enclosure*: 86.1 mm × 447 mm × 620 mm NL-SAS disk enclosure: 175 mm x 447 mm x 488 mm | SAS disk enclosure: 86.1 mm × 447 mm × 410 mm NVMe disk enclosure*: 86.1 mm × 447 mm × 620 mm NL-SAS disk enclosure: 175 mm x 447 mm x 488 mm | ||||
Weight (Excl. Disk Units) | 2.5-inch controller enclosure: 23.75 kg 3.5-inch controller enclosure: 24.1 kg NVMe controller enclosure*: 21.25 kg | 2.5-inch controller enclosure: 38.05 kg 3.5-inch controller enclosure: 38.5 kg NVMe controller enclosure*: 40.65 kg | 2.5-inch controller enclosure: 38.05 kg 3.5-inch controller enclosure: 38.5 kg NVMe controller enclosure*: 40.65 kg | |||
2.5-inch SAS disk enclosure: 13.4 kg 3.5-inch SAS disk enclosure: 26.5 kg NVMe disk enclosure*: 24.95 kg | 2.5-inch SAS disk enclosure: 13.4 kg 3.5-inch SAS disk enclosure: 26.5 kg NVMe disk enclosure*: 24.95 kg | 2.5-inch SAS disk enclosure: 13.4 kg 3.5-inch SAS disk enclosure: 26.5 kg NVMe disk enclosure*: 24.95 kg | ||||
Operating Temperature | -60 m to +1800 m altitude: 5°C to 35°C (cabinet) or 40°C (enclosure)1800 m to 3000 m altitude: The maximum temperature threshold decreases by 1°C for every altitude increase of 220 m | -60 m to +1800 m altitude: 5°C to 35°C (cabinet) or 40°C (enclosure)1800 m to 3000 m altitude: The maximum temperature threshold decreases by 1°C for every altitude increase of 220 m | -60 m to +1800 m altitude: 5°C to 35°C (cabinet) or 40°C (enclosure)1800 m to 3000 m altitude: The maximum temperature threshold decreases by 1°C for every altitude increase of 220 m | |||
Operating Humidity | 10% to 90% RH | 10% to 90% RH | 10% to 90% RH |