3 фазный 11/0. Распределительный трансформатор 38 кВ S11 масляный силовой

Сохранить в закладки 1601208153154:


Цена:1 199,00 $ - 1 299,00 $*

Количество:

  • В избранное

Описание и отзывы

Характеристики





Structural features


S9-M Hermetically sealed oil-immersed power transformer of 6-10kv




Iron core
The iron core is made of cold-rolled grain-oriented silicon steel with high magnetic conductivity, with inclined joint laminated structure. Section of the core limbs is of multi- class ladder round, with uniform section with that of yoke.
Winding
The winding adopts corrugated oil duct with non-dipping process, bound by shrinkable tape; all winding are of concentric coils; taps of HV winding with corresponding tapping voltage shall be led to the tap switch, and the switch shall be installed on the box cover. Power supply must be cut off first when changing the tapping voltage.
Installation of protection device
Transformers of all capacity specifications have been equipped with pressure relief valve.

Gas relay with alarm and tripping terminals is available on request.
Oil-temperature measurement devide
All the transformers are equipped with tube holder for glass-stem thermometer that is set on the top of oil tank,and immersed in oil for about 120 ± 10 mm

1000~2000 kVA transformer is equipped with outdoor signal thermometer
Transformer oil tank
Transformer oil tank is corrugated of corrugated walls with powder painted surface and reinforced and reinforced with film. Corrugated cooling fin not only has cooling function, but also has "breathing" function, the elasticity of corrugated cooling fin make it adapt to the change of oil volume due to change of temperature. So this hermetically does not conservator, which decreases the height of transformer.

The transformer adopts vacuum oil-injection technology during encapsulation that thoroughly removes the moisture from transformer, and keeps the transformer oil from contacting the air. This technology also avoid insulation performance reduction or oil aging due to entering of oxygen or moisture, it improves operation reliability of transformer.


Main technical parameters






Service conditions
Installation height: altitude shall not exceed 1000m

Ambient temperature:-40℃~40℃


Size Slection






Order guide
Please specify the product model, rated capacity, HV/LV rated voltage and high-voltage tapping range, phase number, frequency, connection group symbol and so on in the order.




Related Products




Похожие товары

Новые поступления