Электронный балласт УФ-лампа балласт * УФ-лампа драйвер 1*18 2*18 1*36 2*36 2*36 T8 Флуоресцентный электронный балласт T5 2x28w 220-240V
2 187,87 ₽ - 4 375,74 ₽
Сохранить в закладки 1601220585196:
LPCU-1PH-A-3 | ||
Lamp power(max) (Output power) | 3kW | |
Lamp voltage (Output voltage) | 300V-500V (depend on the lamp) | |
output current | <8.6A | |
Input voltage | 206-278VAC,single phase | |
Input current | 17A(Max)typical valve | |
Input frequency | 46-63Hz | |
Power factor | 0.98(Typical value) | |
Efficiency | >94%(Typical value) | |
Harmonic current distortion | <5%(Typical value) | |
Range of output power | 15%-100% | |
Output frequency | 40-200kHz | |
Ignition voltage | 1650Vp | |
Protect function | Output short circuit protection,Open load protection,Output over voltage protection,Input over voltage protection,Input undervoltage protection,high temperature protection | |
Lamp monitor | Current Monitor,voltage monitor | |
Control way | IO(Compatible with PLC), CAN open, RS485(MODBUS) | |
Working environment temperature | -5℃~+55℃ | |
High humidity | 90% | |
Cooling way | Forced air cooling,water-cooling | |
Protection class | IP20 | |
Size | 329*135*65 | |
Weight | 4kg |
Code switch value | Control way |
0 | hard wire control |
Non O | CAN bus/RS422 bus communication control Code switch value is the communication address |
Pin | Function | Direction | Type | Description |
1 | PLC COM (0V) | Input | 0V | the cathode of external power |
2 | Must Dangling | |||
3 | Fault code 1 | Output | Open connector | Low level means fault(driver fault) |
4 | Fault code 2 | Output | Open connector | Low level means fault(system fault) |
5 | Fault code 3 | Output | Open connector | Low level means fault(indicator light fault) |
6 | START/STOP | Input | 24V | The anode of external power |
7 | Lamp light on signal | Output | Open connector | Low level means lamp works |
8 | Dimming control | Input | PWM | Duty ratio controls power |
PWM Duty ratio | Lamp Power |
<10% | 450W |
10% | 450W |
97% | 3000W |
100% | 3000W |
Name | Description |
RUN | Supply power, “RUN” Lights on, ballast operates. |
LAMP | Indicator light flashes, lamp is on the process of lighting on. Indicator light on stably, lamp finishes starting. Indicator light off, lamp off. |
FAULT | Indicator light on, fault happens. (Ballast default or lamp default) |
TX | Indicator light flashes, communication data is sending. (CAN BUS OR RS485 BUS) Indicator light doesn’t flash, no data is sending. |
RX | Indicator light flashes, communication data is accepting. (CAN BUS OR RS485 BUS) Indicator light doesn’t flash, no data is accepting. |