Hikins 75 г 24 В обратный осмос постоянного тока небольшой очиститель воды усилитель насос для обратного осмоса

Сохранить в закладки 1601233665415:


Цена:933,18 ₽ - 1 027,14 ₽*

Количество:

  • В избранное

Описание и отзывы

Характеристики



Specification


Model
75G 
Rated Voltage (V)
24V DC
Input Pressure (PSI)
20
Rated Curremt (A)
0.8A
Working Flow
≥750ml/min


Products Description




Hikins Factory OEM 75GPD 24V DC Reverse Osmosis RO Diaphragm Booster Pump For Water Purifier
Hikins manufactures a full range of RO booster pumps from 50GPD to 1000GPD for domestic RO water purifier applications, Hikins diaphragm pump is further categorized into self-priming pump with feed water pressure from 0psi and regular booster pump with feed water pressure from 20psi, the RO pump is widely selected for domestic Reverse Osmosis membrane application, and it is fully tested and meeting the relevant RO membrane permeate flow rate. Hikins has a special advantage in injection and tooling production equipment for plastic parts manufacturing, Hikins also has its own copper windering assembly line for motor core production.


This RO pump is combining with the following features:
1) Durable diaphragm material under millions times water leakage test
2) Supreme Copper quality for the motors
3) Low energy consumption
4) Big flux working flow rate compared to our peer manufacturer
5) Patented quick-fit assembly for water input and output
6) Fit to universal RO water purifier requirement
7) Wide product range from 50GPD, 75GPD, 100GPD, 200GPD 300GPD, 400GPD, 500GPD, 600GPD, 800GPD and 1000GPD for all scope application of RO water system












Details Images


Test Conditions:
1.Working voltage:24VDc;
2.Inlet water pressure: 20PSl;
3.Normal working pressure: 70PSl;
4.Working water flow under normal working pressure: no less than 0.75L/Min;
5.Working current under normal working pressure: no more than 0.8A;
6.Closed pressure under 20PSI inlet pressure:130+10PSI;
7.Max current(under 140PSI):no more than 1A;
8.Temperature of the motor surface after 24 hours continuous working: nomore than 60℃;
9.Noise: no more than 40dB.




Notice:
1. This picture is for reference only, the actual size is subject to the product;
2. The water inlet and outlet diameter of the water pump is 3/8" tapered pipe thread;
3. The compression of shock-absorbing rubber should be controlled at 1-1.5MM;
4. The length of the power cord is 40MM;
5. The size unit marked in the picture is MM;
Service Conditions:
1. Ambient conditions: Temperature:4℃~40℃. Relative humidity: less than 90%(25℃)
2. Limited conditions of inlet water
2.1 Source water: Municipal tap water or other municipal central water
2.2 Inlet water pressure: 0.1-0.4Mpa
2.3 Inlet water temperature:5℃-38℃
3.Power supply voltage:(24±0.5)V DC
4. Working mechanism: Intermittent work, reasonably working less than 6 hours per day


Company Profile




ABOUT US
Hikins (Jiangsu) Envirotech Co., Ltd is an industry leader in the drinking water industry. As an OEM and ODM manufacturer of RO water purifiers, RO membranes, RO pumps and robot vacuum cleaners, we have complete production facilities and equipment and can provide zero Parts and accessories manufacturing, we have multiple assembly lines to meet heavy production, besides, we are an experienced exporter in OEM manufacturing, and we have good product quality control and delivery supply chain management.

We are looking for agents and distributors, please contact us now to become a potential partner for our global business
development.










Certifications




Exhibition




FAQ


FAQs on Reverse Osmosis RO Pumps OEM manufacturing
Q1: What is the purpose of diaphragm pump?
A1: The diaphragm pump is specially chosen for RO system because it does not require constant working for the pump, and the working process is controlled by the pressure change and water flow change from the water supply side to the treated water side.The diaphragm pump works by using the motor part to generate power and water flow to the water chamber of the pump head, the deliver water with enhanced pressure for the RO membrane, the diaphragm pump is taken as the heart of the RO system to provide running power.

Q2:What is the structural component of the diaphragm pump?
A2: The pump is composed of the pump head, and the motor part, the pump head part is further composed of the diaphragm, the valve seats, the water input and output valve, the piston, the cover, the motor is composed of iron-core and copper winding, the rotator, the shell and the end cap.

Q3: How to select the pump for the RO system?
A3: The selection of the pump shall be meeting the requirement of the RO system, total water volume of input water volume and output volume of the RO system should be considered, the pump working flow rate should be equal to the total water volume of the RO system..

Q4: How to select the transformer for the pump?
A4: Hikins pump has 24V and 36V two categories, each model of the pump has a maximum electrical current, the transformer selection should be based on the max working current of the pump, I the transformer current is smaller than the pump max working current,the transformer will be easily get burnt.

Q5: How do we avoid pump leakage?
A5: Make sure the feed water is pre-treated and free of sand before the water goes to the pump system, to change the pre-filters of the RO system often.

Q6: What is the best position to put the pump?
A6: To make sure water will not goes into the motor side and cause problem, pump is suggested to be assembled either horizontally or vertically with the pump head down.

Q7: Can the pump being used for oil material?
A7: It’s not suggested for the pump to be used for oil material as the valve will be easily get blocked.

Q8: Can we discharge the pump and check it on our own?
A8: The pump has been properly tested and safe sticker has been added to the pump, please do not discharge it unless under proper instruction from pump professionals.