Product Description






GEL (Deep Cycle GEL) series is designed for frequent cyclic charge and discharge applications under extreme enviroments. By using strong grids, high purity lead and patented Gel electrolyte, GEL series offers excellent recovery after deep discharge under frequent cyclic discharge, and can deliver 400 cycles at 100% DOD. Suitable for solar, CATV, marine, RV and deep discharge UPS etc.




Configuration




Battery Terminal Options


T1 Terminal
FASTON TYPE (Copper) quick disconnect tabs; silver coating for better conductivity
T2 Terminal
FASTON TYPE (Copper) quick disconnect tabs; silver coating for better conductivity


T3 Terminal
Brass Coated With Tin
Torque: 3.9 ~ 5.4 N*m(34.39 ~ 47.75 in*lbs)
T4 Terminal
Brass Coated With Tin


T5 Terminal
Lead Torque: 3.9 ~ 5.4 N*m(34.39 ~ 47.75 in*lbs)
T6 Terminal
Brass Coated With Tin; Threaded Insert 6mm STUD Torque: 3.9 ~ 5.4 N*m(34.39 ~ 47.75 in*lbs)


T7 Terminal
Brass Coated With Tin; Threaded Insert 6mm STUD Torque: 3.9 ~ 5.4 N*m(34.39 ~ 47.75 in*lbs)
T9 Terminal
Lead Torque: 11 ~ 14.7 N*m(97.28 ~ 130.0 in*lbs)


Specification


Model
6-GFM-100Ah
6-GFM-150Ah
6-GFM-200Ah
6-GFM-250Ah
Cells Per Unit
6
Voltage Per Unit
12V
Capacity
100Ah@10hr-rate to 1.80V per cell @25°C
150Ah@10hr-rate to 1.80V per cell @25°C
200Ah@10hr-rate to 1.80V per cell @25°C
250Ah@10hr-rate to 1.80V per cell @25°C
Weight
29kg
42kg
58.5kg
67kg
Internal Resistance
Approx. 6mΩ
Approx. 4mΩ
Approx. 3.5mΩ
Approx. 2.5mΩ
Terminal
F1/F2
Max. Discharge Current
1500A(5s)
2250A(5s)
3000A(5s)
3750A(5s)
Design Life
10~15 years
Maximum Charging Current
25A
37.5A
50A
62.5A
Float Charging Voltage
13.6 V~13.8 V @ 25°C
Temperature Compensation: -20mV/°C/Cell
Cycle Use Voltage
14.4 V~14.9 V @ 25°C
Cycle Use Voltage
Temperature Compensation: -30mV/°C/Cell
Operating Temperature Range
Discharge: -20°C~60°C
Charge: 0°C~50°C
Storage: -20°C~60°C
Container Material
A.B.S. UL94-HB, UL94-V0 Optional.


Features:
* Maintenance free and longer cycle life
* Safety and no leakage
* Excellent recharge and discharge performance
* Low self-discharge rate and good deep discharge performance
* Adapt to high or low temperature


Characteristics Data










Show Details






Company Profile




As a world-class solar products manufacturer, Sunpal specializes in the research, development, production, and sales of solar PV products, mainly in charge of solar panels, solar batteries, solar inverter and a complete solar system.
Sunpal is accredited as Batch I Smart Manufacturing Plant by Jiangsu Government, the Witness Laboratory Accreditation Certificate(WMTC) by CE.ISO Laboratory Certificate by TUV SUD.
Sunpal focused on research and manufacture of solar battery since the year 2005, we have exported our various kinds of battery to 86 countries and won a good reputation in quality. With over 10 years of development, Sunpal now has factory area covering 150,000 square meters, with 600 experienced employees.






Packing and Delivery






Certifications




Strict QC System
We have always prided ourselves on the quality of our technical support. We maintain laboratory and testing facilities containing the latest state-of-the-art equipment. All our batteries are subject to stringent quality controls throughout every step of manufacturing and through to their final dispatch.




FAQ


1.How long can a battery last?
The service design life of a battery varies considerably with how it is used, how it is maintained and charged, temperature, among other factors.

2.Do I need to add water to my battery?
No. Sealed lead acid batteries do not require the use of water.

3.What determines the life of a VRLA battery?
Sealed lead acid battery life is determined by many factors. These include temperature, depth and rate of discharge, and the number of charges and discharges (called cycles).

4.What is the difference between float and cycle applications?
A float application requires the battery to be on constant charge with an occasional discharge. Cycle applications charge and discharge the battery on a regular basis.

5.What is the definition of "cycle use" and "standby use"?
“Cycle Use” – direct power source: Cycle Use – IT can provide the power supply to power tools, and portable electronic products. It can also be used for cycling charging and discharging usage such as electronics motorbike or vacuum cleaner. “Standby Use” – back up power: Standby Use is mainly used for emergency power to avoid future damage that may be caused by a sudden power outage.

6.When should a deep-cycle battery be used?
Deep-cycle batteries are used when 50% or more of the capacity is used per cycle. The most common use of deep-cycle batteries is in applications that require deep, repetitive drain, like powerful car audio systems, trolling motors, golf carts, electric wheelchairs, or RV house power sources. Public safety and high performance vehicles are other applications that call for the special characteristics of deep-cycle batteries.

7.How are batteries rated?
Lead acid batteries are rated based on a capacity given in a defined time. There is not a set industry standard for how to rate a battery.