Манекен для взрослых половина тела CPR манекен обучения медицинской науки модель CPR со светодиодным индикатором

Сохранить в закладки 1601260060373:


Цена:21 349,53-25 500,83 ₽*

Количество:

  • В избранное

Описание и отзывы

Характеристики







Half Body Adult CPR Manikin No.CPR195
Functional features:
1、Simulate the standard airway opening.
2、Electronic monitoring of the CPR operation process, the simulator left and right shoulder indicator light display.
Simulation mannequin's right shoulder indicator light functions:
* When blowing air enters the stomach, the air-to-stomach indicator light (yellow) on the right shoulder turns on, accompanied by a beep.
* When the compression location is correct, the compression position indicator light (green) on the right shoulder turns on; if the compression position is incorrect, the green light on the right shoulder turns off and is accompanied by a beep.
* When the compression rate is less than 100 times per minute, the too slow frequency indicator light (red) on the right shoulder turns on, accompanied by a beep.
* When the compression rate exceeds 120 times per minute, the too fast frequency indicator light (blue) on the right shoulder turns on, accompanied by a beep.

Simulation mannequin's left shoulder indicator light functions:
* When the airway is open, the airway indicator light (blue) on the left shoulder turns on; when the airway is closed, the blue light on the left shoulder turns off.
* When the compression depth is less than 5cm, the insufficient depth indicator light (yellow) on the left shoulder turns on, accompanied by a beep.
* When the compression depth is between 5cm and 6cm inclusive, the compression is normal, and the normal compression indicator light (green) on the left shoulder turns on.
* When the compression depth exceeds 6cm, the excessive depth indicator light (red) on the left shoulder turns on, accompanied by a beep.
* When the tidal volume during ventilation is less than 500ml, the insufficient tidal volume indicator light (yellow) on the left shoulder turns on, accompanied by a beep.
* When the tidal volume during ventilation is between 500ml and 1000ml inclusive, ventilation is normal, and the normal
ventilation indicator light (green) on the left shoulder turns on.
* When the tidal volume during ventilation exceeds 1000ml, the excessive tidal volume indicator light (red) on the left shoulder turns on, accompanied by a beep.

Operation Frequency: According to the latest international standards, the rate should be 100-120 compressions per minute, marked by a "beep" sound.





















FAQ


A) How could I get a sample?
Before we received the first order, please afford the sample cost and express fee. We will return the sample cost back to you within your first order.
B) Sample time?
Existing items: Within 15 days.
C) Whether you could make our brand on your products?
Yes. We can print your Logo on both the products and the packages if you can meet our MOQ.
D) Whether you could make your products by our color?
Yes, The color of products can be customized if you can meet our MOQ.
E) How to guarantee the quality of your products?
1) Strict detection during production.
2) Strict sampling inspection on products before shipment and intact product packaging ensured.


Welcome to order!


Похожие товары

Новые поступления

Новинки товаров от производителей по оптовым ценам