Product model | Voltage level | Input power | Power range | ||
DC | AC | ||||
ZK200-1T-xxG-P | 110V | 90-400VDC | Single-phase 110VAC | 0.75-1.5kW | |
ZK200-2T-xxG-P | 220V | 150-450VDC | Single-phase 220VAC | 0.4-2.2kW | |
ZK200-4T-xxG-P | 380V | 250-800VDC | Three-phase 380VAC | 0.4-22kW |
Solar Pump Inverter Power (KW) | Pump | Maximum Input Power of Solar panel(KW) | Maximum Input DC Voltage(V) | Total Voc range (V)of Recommended Panels | Rated Output Current(A) | Output Frequency Range(Hz) | ||||||||
Rated Power (KW) | Rated Voltage (V) | |||||||||||||
ZK200-1T Series: Input 90-400VDC, 3 Phase 110-230VAC Output, Suitable for AC 110V Pumps | ||||||||||||||
0.75 | 0.75 | 110 | 1.0 | 400 | 175-380 | 7.0 | 0-599.00 | |||||||
1.5 | 1.5 | 110 | 1.95 | 400 | 175-380 | 9.6 | 0-599.00 | |||||||
ZK200-2T Series: Input 150-450VDC,3 Phase 150-230VAC Output, Suitable for AC 220V Pumps | ||||||||||||||
0.4 | 0.4 | 220 | 0.55 | 450 | 360-430 | 2.3 | 0-599.00 | |||||||
0.75 | 0.75 | 220 | 1.0 | 450 | 360-430 | 4.0 | 0-599.00 | |||||||
1.5 | 1.5 | 220 | 1.95 | 450 | 360-430 | 7.0 | 0-599.00 | |||||||
2.2 | 2.2 | 220 | 2.86 | 450 | 360-430 | 9.6 | 0-599.00 | |||||||
ZK200-4T Series: Input 250-800VDC 3 Phase 230-460VAC Output, Suitable for AC 380V Pumps | ||||||||||||||
0.4 | 0.4 | 380 | 0.6 | 800 | 620-750 | 1.5 | 0-599.00 | |||||||
0.75 | 0.75 | 380 | 1.0 | 800 | 620-750 | 2.5 | 0-599.00 | |||||||
1.5 | 1.5 | 380 | 2.2 | 800 | 620-750 | 3.8 | 0-599.00 | |||||||
2.2 | 2.2 | 380 | 3.3 | 800 | 620-750 | 5.1 | 0-599.00 | |||||||
4.0 | 4.0 | 380 | 5 | 800 | 620-750 | 9.5 | 0-599.00 | |||||||
5.5 | 5.5 | 380 | 8 | 800 | 620-750 | 13 | 0-599.00 | |||||||
7.5 | 7.5 | 380 | 10 | 800 | 620-750 | 17 | 0-599.00 | |||||||
11 | 11 | 380 | 14.3 | 800 | 620-750 | 25 | 0-599.00 | |||||||
15 | 15 | 380 | 19.5 | 800 | 620-750 | 32 | 0-599.00 | |||||||
18.5 | 18.5 | 380 | 23.4 | 800 | 620-750 | 37 | 0-599.00 | |||||||
22 | 22 | 380 | 28.6 | 800 | 620-750 | 45 | 0-599.00 |
Items | Specifications | ||||||
Power input | Voltage | 1T: 90VDC to 400VDC 2T: 150VDC to 450VDC 4T: 250VDC to 800VDC | |||||
Frequency | 50Hz/60Hz, Tolerance ±5% | ||||||
Voltage range | Continuous voltage fluctuation ±15%,short fluctuation -15% ~ +15% | ||||||
Voltage out-of-balance rate<3% | |||||||
Total Voc range (V) of recommended panels | 1T Type: 175-380VDC 2T Type: 360-430VDC 4T Type: 620-750VDC | ||||||
Power output | Adaptive motor type | three-phase asynchronous motor, Permanent magnet synchronous motor | |||||
Output voltage (V) | three-phase: 0% ~ rated input voltage,error < ±3% | ||||||
Output frequency (Hz) | 0.00% ~ 599.00Hz; Unit: 0.01Hz | ||||||
Overload capacity | 150% rated current/1 min, 180% rated current/10s, 200% rated current/0.5s | ||||||
Basic functions | ACC/DEC time | 0.0 ~ 30000s | |||||
Switching frequency | 0.5kHz ~ 16kHz | ||||||
Frequency setting | Digital setting + control panel, Communication, Analog setting, Terminal pulse setting | ||||||
Motor start-up methods | Started from starting frequency,Speed tracking start | ||||||
Motor stop methods | Ramp to stop, Free stop | ||||||
Protection function | Solar pump protection function | Dry run, Low frequency, Low power, Dormancy, Water full, Pump over current protection | |||||
Basic protection function | nverter unit protection,Overcurrent during acceleration,Overcurrent during deceleration,Over current at constant speed,Overvoltage during acceleration,Overvoltage during deceleration,Overvoltage at constant speed,Undervoltage, Power input phase loss,Power output phase loss,Inverter overload,Motor overload,Current detection fault,Inverter temperature exceeds the limit,Load becoming 0,Too largespeed deviation,Short circuit to ground,External equipment fault,Fast current limit fault,Communication fault,Master slave control communication disconnection,EEPROM read-write fault,PID feedback lost during running,Data storage fault,Control power supply fault,Motor switchover fault during running,Accumulative running timereached | ||||||
Featured functions | Parameter copy,parameter backup,common DC bus,free switchover between two motors’ parameters,flexible parameter displayed & hidden,various master & auxiliary setting and switchover,flying start,a variety of Accel/Decel curves optional, brake control,16-step speed control programmable (2-step speed supports flexible frequency command),wobble frequency control,fixed length control,count function three history faults,over excitation brake,over voltage stall protection,under voltage stall protection,restart on power loss,skip frequency, frequency binding,four kinds of Accel/Decel time,motor thermal protection,flexible fan control,process PID control,simple PLC,multi-functional key programmable,droop control, autotuning,field-weakening control,high-precision torque restraint,V/f separatedcontrol | ||||||
Environment | Place of operation | Indoors,no direct sunlight,free from dust,corrosive gases,flammable gases,oil mist,water vapor,water drop or salt,etc. | |||||
Altitude | 0~2000m. De-rate 1% for every 100m when the altitude is above 1000 meters | ||||||
Ambient temperature | -10℃~ 50℃ ,The rated output current should be derated 1% for every 1℃ when the ambient is 40℃~ 50℃ | ||||||
Relative humidity | 0~95%, no condensation | ||||||
Vibration | Less than 5.9m/s² (0.6g) | ||||||
Storage temperature | -20℃~ +60℃ | ||||||
Others | IP grade | IP20 | |||||
Cooling method | Forced air cooling,Natural cooling |