Новый оригинальный Aruba R8N89A переключатель Aruba 6000 12 г CL4 2X SFP Swch 139 Вт POE коммутатор 4x1G SFP сетевой коммутатор
59 403,41 ₽ - 64 803,72 ₽
Сохранить в закладки 1601272270187:
Item | Details |
Description | S5731-S8UM16UN2Q (8*100M/1/2.5/5/10G,16*100M/1/2.5G ports, 2*40GE QSFP ports or 12*100M/1/2.5/5/10G,12*100M/1/2.5G ports, 4*10GE SFP+ ports, PoE++, without power module) |
Part Number | 02354VCD |
Model | S5731-S8UM16UN2Q |
First supported version | V200R022C00 |
Item | Specification |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) |
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 454.0 mm (1.72 in. x 17.4 in. x 17.87 in.) | |
Dimensions with packaging (H x W x D) [mm(in.)] | 185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 6.83 kg (15.06 lb) |
Weight with packaging [kg(lb)] | 9.81 kg (21.63 lb) |
Typical power consumption [W] | 126 W |
Typical heat dissipation [BTU/hour] | 429.93 BTU/hour |
Maximum power consumption [W] | Without PoE: 171 W |
Full PoE load: 2571 W (PoE: 2268 W) | |
Maximum heat dissipation [BTU/hour] | Without PoE: 583.48 |
Full PoE load: 8772.60 | |
MTBF [year] | 54.08 year |
MTTR [hour] | 2.22 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | Three 600 W AC PoE power modules with 30% load: 50.50 dBA |
Three 1000 W AC PoE power modules with 30% load: 52.50 dBA | |
Three 1000 W DC PoE power modules with 30% load: 52.50 dBA | |
Noise at normal temperature (acoustic pressure) [dB(A)] | Three 600 W AC PoE power modules with 30% load: 36.82 dBA |
Three 1000 W AC PoE power modules with 30% load: 38.82 dBA | |
Three 1000 W DC PoE power modules with 30% load: 38.82 dBA | |
Number of card slots | 0 |
Number of power slots | 3 |
Number of fans modules | 2 |
Redundant power supply | 1+1+1 |
Pluggable AC and DC power modules can be used together in the same switch. | |
Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met: | |
The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year. | |
The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours. | |
The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year. | |
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. | |
Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. | |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Power supply mode | Pluggable power supply |
Rated input voltage [V] | AC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC; 50/60 Hz |
High-voltage DC input: 240 V DC | |
DC input: –48 V DC to –60 V DC | |
Input voltage range [V] | AC input: 90 V AC to 290 V AC; 45 Hz to 66 Hz |
High-voltage DC input: 190 V DC to 290 V DC | |
DC input: -38.4 V DC to -72 V DC | |
Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
Memory | 2 GB |
Flash memory | 1 GB in total. To view the available flash memory size, run the display version command. |
Console port | RJ45 |
Eth Management port | RJ45 |
USB | Supported |
RTC | Supported |
RPS input | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Power supply surge protection [kV] | Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode |
Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode | |
Types of fans | Built-in |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction | Air intake from the front and left and air exhaust from the rear |
PoE | Supported |
Certification | EMC certification |
Safety certification | |
Manufacturing certification |