R290 AIO Mute 1600W Heating 300W Power Top COP 300L Enamelled Tank 80d Hot Water Heated A+ Free Cool Air All In One Heater Pump


Product Features




LCD Intelligent control
Large panel LCD intelligent control multi-function mode selection, easy to operate, save time.

First class energy efficiency
Built-in electronic expansion valve, intelligent control of refrigerant flow, precise temperature control,energy saving and environmental protection.

Super mute
Sound insulation board sealed cabin, optimized design of noise reduction system of the whole machine, library-level mute.

Micro-Channel Heating Pipe to achieve heat exchanging.
Ensure high effecient heat exchanging rate, while decrease the abrasion of gas circulation to enamelled inner water tank.
R290 AIO Mute 1600W Heating 300W Power Top COP 300L Enamelled Tank 80d Hot Water Heated A+ Free Cool Air All In One Heater Pump
Durable (Enamelled Water Tank)
Extra corrosion resistance+ Anti-bacterial properties

International well-known brand heat pump compressor, stable operation at high and low temperature, safe and reliable.

Wire control + Wifi App
Beautiful and delicate control panel, which can be installed anywhere on the wall, easy to use and full of high-end style.






Parameter


Model No.
ADC-08-200
ADC-08-300
Power supply
220-240V~, 1Ph, 50Hz
220-240V~, 1Ph, 50Hz
Nominal tank volume
L
200
300
ErP level (7/6℃ Average ) 55℃ HW
A+
A+
Heating capacity              (20/15℃ Indoor air)
W
1130
1600
Heating capacity                   (7/6℃ Average climate)
W
850
1210
EBH (Electric backup heater)
W
1500
1500
Input (Heat pump only)
W
276
395
COP @ 20/15 ℃ Indoor air
4.10
4.05
COP @ 7/6 ℃ Average climate
3.10
3.20
Current (Heat pump only)
A
1.2
1.8
Max. input(Heat pump+EBH)
W
1913
2093
Max. current
A
8.5
9.3
Air flow
m3/h
270
360
Max. water temperature outlet
°C
70
70
Hot water yield @ 20/15 ℃ Indoor air
L/h
24
34
Available
About 2-3 peoples
About 3-5 peoples
Working ambient temperature
-10°C-43°C
-10°C-43°C
Sound pressure level
dB(A)
48
49
Sound power level
dB(A)
57
59
Max. operating water pressure
MPa
0.8
0.8
Water resistance
IPX1
IPX1
Refrigerant type / Factory charged
R290 /150g
R290 /150g
Throttling type
Electric expansion valve
Electric expansion valve
Compressor
Model
5.8CC
8.18CC
Type ×Quantity
Rotary ×1
Rotary ×1
Brand
GMCC
GMCC
Capacitor
15μF/450V
20μF/450V
Oil type / charged
ESTEL oil XS-601C1 / 140ml
ESTEL oil XS-601C1 / 140ml
Evaporator
Fin material
Hydrophilic aluminum
Hydrophilic aluminum
Tube
Material
Inner groove copper tube
Inner groove copper tube
Outside diameter
mm
Φ5
Φ5
Fan motor
Motor model
BLDC
BLDC
Brand
Welling (Foshan)
Welling (Foshan)
Quantity
1
1
Speed
rmp
800-900
950-1100
Protection
Internal
Internal
Fan type ×Quantity
Centrifugal ×1
Centrifugal ×1
Fan diameter×Height
mm
Φ192×82
Φ192×82
Tank
Inner tank material
Enamel
Enamel
Inner tank outside diameter
mm
Φ470
Φ540
Usable storage volume
L
192.6
293.5
Inner tank thickness
mm
2.0/2.5
2.0/3.0
Max. inner tank pressure
bar
8
8
Insulation
Polyurethane
Polyurethane
Outer tank material
Galvanized steel
Galvanized steel
Outer tank thickness
mm
0.6
0.6
Condenser coil
Standard type
Micro Channel Heat Exchanger wrapped the external of inner tank
Corrosion proof
Magnesium anode
Magnesium anode
Solar coil (Customized)
Inlet water pipe connection
\\
\\
Outlet water pipe connection
\\
\\
Material
\\
\\
Heat-exchange area
\\
\\
Max. pressure
bar
10
10
Dimensions
Inlet water pipe connection
mm
DN20
DN20
Outlet water pipe connection
mm
DN20
DN20
Condensing water connection
mm
1/4‘, internal thread
1/4‘, internal thread
Unit dimension (ΦD×H)
mm
Φ570×1900
Φ640×2,010
Packing dimension (L×W×H)
mm
645*645*(1880+110)(enclude Bracket)
740*740*(2090+110)(enclude Bracket)
Weight
Net / Gross weight
kg
90/ 101
105/ 117
Notes:
The specification may be changed for product improvement, please refer to the nameplate of product.
Condition - Ambient: 20°C DB/15°C WB, initial water temperature is 15°C, ending water temperature is 55°C.


Detailed Image








R290 AIO Mute 1600W Heating 300W Power Top COP 300L Enamelled Tank 80d Hot Water Heated A+ Free Cool Air All In One Heater Pump








Certificates




Performance




ErP Energy Labels on R290 AIO Mute 1600W Heating 300W Power Top COP 300L Enamelled Tank 80d Hot Water Heated A+ Free Cool Air All In One Heater Pump




Products in Line








Packages & Shipment






Application




SG-Ready Control/Installation Principle: R290 AIO Mute 1600W Heating 300W Power Top COP 300L Enamelled Tank 80d Hot Water Heated A+ Free Cool Air All In One Heater Pump






(1) Waste heat is useful heat
The standard hear exchanger of the hot-water heat pump enables direct connection to a second heat generator,e.g. a solar heating system or a boiler.


(2) Dehumidification in the recirculating air mode
Dehumidified air in the laundry room supports laundry drying and prevents moisture-induced damage.


(3)Cooling in the recirculating air mode
The room air is extracted from the storage room or a wine
cellar,subsequently cooled and dehumidified in the heat pump and finally re-introduced into the room.Recreation rooms,boiler rooms or utility rooms are ideal installation sites. The air ducts leading through warm sections must be insulated to prevent the formation of condensation.


(4)Variable change over of intake air
A duct system with integrated bypass flaps allows for variable utilization of the heat contained in the outside air or room air for the production of hot water.
R290 AIO Mute 1600W Heating 300W Power Top COP 300L Enamelled Tank 80d Hot Water Heated A+ Free Cool Air All In One Heater Pump
Installation attentions
①Choose the right path to move the unit;
②Try to move the unit as original case;
③If the unit installed in the building of the metal part,it must work for electrical insulation and comply with the relevant technical standards of electrical equipment.




Further concerns on installation, optional heat exchanger coil built-in, shipment, leadtime, promotional price etc, just feel free to send us an inquiry on R290 AIO Mute 1600W Heating 300W Power Top COP 300L Enamelled Tank 80d Hot Water Heated A+ Free Cool Air All In One Heater Pump


Похожие товары

Новые поступления

Новинки товаров от производителей по оптовым ценам