Cleaning machine fault analysis and elimination
Fault performance | Main reason | Solution | |
1 | The power end is abnormal when the pump is running | Water in crankcase causes lubricating oil to emulsify | Change lubricating oil |
Connecting rod bearing wear | Replacement bearing bush | ||
Bearing failure | Bearing replacement | ||
2 | Transmission end middle rod oil leakage | The oil level of lubricating oil is too high | Release a little lubricating oil |
Skeleton oil seal damaged aging | Replace the skeleton oil seal | ||
3 | Pressure gauge display fluctuation (high pressure hose shaking violently) | The valve or spring is broken | Check and replace |
The seal packing or valve of the pump is badly worn | Check and replace | ||
The spool has impurities | Check and remove impurities | ||
Ultra-high pressure pump water supply is insufficient | Troubleshoot mechanical faults according to water pressure | ||
4 | Water pressure alarm | The water tank has no liquid level or the liquid level is very low | Check water supply source |
Y-type filter is blocked | Y-type filter is blocked | ||
Bag filter built-in bag clogging | Clean or replace cloth bags | ||
Low pressure gauge reading above filter | Check pipe pump | ||
The tank float falls off and blocks the outlet | Reattach |
Cleaning media | Clean water |
Power (watts) | 250000 |
Maximum pressure | 200MPa/2000bar |
Keywords | Ultra High pressure water pump |
Function | Cleaning Appliances |
Usage | Paint removal |