Сохранить в закладки 1601288398387:
Features:
1. 180-264V AC ,245 ~373VDC Input
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 36 months warranty







| Model | XLG-800-24 | XLG-800-36 | XLG-800-48 | XLG-800-60 |
| DC output voltage | 24V | 36V | 48V | 60V |
| Rated output current | 27A | 22A | 16.5A | 13.5A |
| Current range | 0~27A | 0~22A | 0~16.5A | 0~13.5A |
| Output power | 648W | 792W | 792W | 810W |
| Wave and noise | 200mVp-p | 220mVp-p | 240mVp-p | 240mVp-p |
| Voltage accuracy | ± 2% | ± 1.5% | ± 1.5% | ± 1.5% |
| Line regulation | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
| Load regulation | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% |
| Start, rise, hold time | 500ms,50ms,24ms/230VAC (at full load) | |||
| Input voltage range | 180 ~264VAC,245 ~373VDC | |||
| Frequency range | 47 ~ 63Hz | |||
| AC input current | 7.5A/230VAC | |||
| Efficiency | 91.5% | 93.0% | 93.5% | 94.0% |
| Impulse current | Cold start current 65A/230VAC | |||
| Leakage current | <2mA/240VAC | |||
| Overcurrent protection | 95%~108% of the rated output current starts overcurrent limit, recover automatically after abnormal conditions are removed | |||
| Short circuit protection | Protection mode: Hiccup mode: recover automatically normal output after abnormal conditions are removed | |||
| Overvoltage protection | 115%~ 135% of rated output voltage startup overvoltage protection | |||
| Protection mode: Hiccup mode: recover automatically normal output after abnormal conditions are removed | ||||
| Over temperature protection | 105℃ ±5℃ (JK1/JK2 is next to the transformer/MOS tube surface detection) | |||
| Protection mode: Turn Off the output voltage, and the normal output can be automatically restored after the temperature drops | ||||
| Working temperature | -20℃~ +60℃ | |||
| Working humidity | 20% ~90% RH, non condensing | |||
| Storage temperature and humidity | -40℃~ +85℃;10% ~95% RH,non condensing | |||
| Seismic resistance | 10~500Hz,,3G 10min/ 1 cycle,X, Y, Z axes,duration 60 minutes | |||
| Pressure resistance | I/P~O/P:1.5KVAC I/P~FG:1.5KVAC O/P~FG:0.5KVAC | |||
| Isolation resistance | I/P~O/P,I/P~FG,O/P~FG: 100M Ohms/500VDC/25℃/70%RH | |||
| Safety standard | Compliance to UL60950-1,TUV EN60950-1 | |||
| Electromagnetic compatibility emission | Compliance to EN55022 Class A | |||
| Electromagnetic compatibility immunity | Compliance to EN55024 | |||
| Dimension | 265*120*56mm (L*W*H) | |||
| Packing | 2.75kg/6pcs/17.5kg/0.033 cubic meters | |||





--How much voltage can you provide?
--5V, 9V, 12V, 13.8V, 15V, 18V, 24V, 36V, 48V, 50V, 60V, 110V (depending on the product).
--How much current can you provide?
--0.5A, 1A, 1.5A, 2A, 3A, 4A, 5A, 6A, 10A, 15A, 20A, 30A, 40A, 50A, 60A, 80A, 100A.
--How is the quality?
--We have the most professional and experienced engineers and strict quality assurance and quality control system. 0.3% return rate.
--How long is your delivery time?
--Delivery time is 1-25 days, depending on the detailed items and quantity.
--Can we be your distributor?
--We are looking for global switching power supply distributors and agents. If you are interested, please feel free to send your message or ask
--Which payment method do you accept?
--T/T, LC, D/P, D/A, OIA, paypal, trade assurance.
--What is your MOQ?
--1 piece.
--Do you accept OEM ODM?
--Yes.