Performance parameter: | E7 handheld patient monitor is suitable for patient transport, rounds, outpatient clinics, operating room and other places, suitable for neonatal, pediatric, adults, the elderly and other groups of people. --Standard Configuration:SpO2, PR/HR, NIBP, ECG, RESP,TEMP ; --Optional :ETCO2 --7inch color TFT LCD,rechargeable lithium battery ,both AC and DC; --With multi-language operation interface; --Fanless design,quite,quite energy saving and clean; --Monitor adults,childrenand newborn; --Simulated blood oxygen technology,anti-motion interference,anti-environmental light interference; --Blood pressure data storage;Reviewof alarm events; --Drug concentration calculation and titration table functions; --Support Wifi/Wired networking to realize central monitoring systerm ; --The shell is made of imported ABS material which is more corrosion- resistant.; --Multi-channel synchronous ECG algorithm,support ST and ARR analysis,abnormal ECG analysis Product Size 246.5*146.4*50.7mm Product weight 950g WiFi connection APP can be realized to achieve intelligent interconnection 4 hours of standby time and 3 hours of working time ECG: Gain: X0.25, X0.5, X1, X2, Auto Timebaseline selection: 12.5mm/s, 25mm/s, 50mm/s Sensitivity>200uV (peak-to-peak) bandwidth: Diagnostic mode: 0.05~130Hz Monitoring mode: 0.5~40Hz Operation mode: 1~20Hz Common Mode Rejection Ratio: Diagnostic mode: >90dB Custody mode: >100dB Operation mode: >100dB Electrode polarization voltage: ±300mV Input impedance: <20% DC bias voltage: -300mV~ 300mV Multi-channel crosstalk: <5% ST segment detection measurement: Measurement range: -2.0mV~+2.0mV Measurement accuracy: the measurement error between-0.02 mV and + 0.8 mV is ± 0.02 mV or ± 10%. Other scope is not defined NIBP: Adult systolic blood pressure: 40~270mmHg Diastolic blood pressure: 10~210mmHg Average pressure: 20~230mmHg Children systolic blood pressure: 40~200mmHg Diastolic blood pressure: 10~150mmHg Average pressure: 20~165mmHg Neonatal systolic blood pressure: 40~135mmHg Diastolic blood pressure: 10~95mmHg Average pressure: 20~110mmHg Static pressure range: 0~300mmHg Static pressure accuracy : 3mmHg Blood pressure accuracy: maximum average error 5mmHg; maximum standard deviation 8mmHg Overvoltage Protection: Adult mode: 300 mmHg±10mmHg Child mode : 240mmHg±10mmHg Neonatal mode : 150mmHg±10mmHg SPO2: Measuring range 0~100% Resolution 1% The accuracy is within the range of 70% to 100%, and the measurement error should be ±4%; In the range of 0% to 69%, the measurement error is undefined Pulse rate: Measuring range 25~250bpm Resolution 1bpm Accuracy ±3bpm Refresh time 1s Heart rate: 15 to 300 bpm for adults (beat / min) Newborn / child 15-350 bpm (beat / min) Accuracy: ± 1% or ± 1 bpm, take the large one TEMP: Range 0~50ºC Resolution 0.1ºC Accuracy ±0.1ºC (without probe error) |
Standard Environment | ECG lead line Cuff SpO 2 sensor TEMP probe Lithium-ion battery Power cable Operator’s manual |
Optional | End-tidal CO2 (optional) Monitor bracket trolley (optional) Monitor wall bracket (optional) |
Новинки товаров от производителей по оптовым ценам