Medical Oxygen Generator
How PSA Oxygen Generator Work
Model | Oxygen Purity(Volume Fraction)/10² | Oxygen Capacity(Nm³/min) | Air Consumption(M³/min) | Suitable Scale(Bed/pec) | Power(KVA) |
MPS93-2 | ≥90 | 2 | 0.5 | 50~60 | 3.7 |
MPS93-3 | ≥90 | 3 | 0.6 | 60~120 | 4.5 |
MPS93-5 | ≥90 | 5 | 0.75 | 150~200 | 8.0 |
MPS93-10 | ≥90 | 10 | 1.5 | 200~400 | 12.0 |
MPS93-20 | ≥90 | 20 | 3.0 | 400~600 | 23.5 |
MPS93-30 | ≥90 | 30 | 4.5 | 600~900 | 32.0 |
MPD93-30 | ≥90 | 30*2 | 4.5*2 | 600~1800 | 64.0 |
MPS93-40 | ≥90 | 40 | 6.0 | 900~1200 | 39.5 |
MPD93-40 | ≥90 | 40*2 | 6.0*2 | 900~2400 | 79.0 |
MPS93-60 | ≥90 | 60 | 9.0 | 1400~1800 | 58.0 |
MPS93-80 | ≥90 | 80 | 12.0 | 1800~2400 | 78.0 |
MPS93-120 | ≥90 | 120 | 18.0 | 2400~3600 | 115.0 |
FAQ
Q: What the oxygen purity of this machine can be achieved?
This is our high purity model,it is can be produce 99%~99.7% oxygen purity.
Q: The more information you kindly tell us,the better professional service we provide for you !
a. What is the gas source you currently use?(cylinder/dewar/liquid gas/other)
b. Gas consumption?(Nm3/h,L/min)
c. Required gas pressure?
d. Required gas quality?(eg:Maximum oxygen percentage, Maximum moisture content, etc)
Q: Oxygen equipment is safety?
Definitely!Nitrogen/Oxygen generator is a kind of air separation device under normal temperature, it can supply stable and continuous nitrogen/oxygen gas, it doesn’t need any high-pressure cylinders and liquid cylinders which have potentially dangerous; so we don’t need
to worry about no-timely supply due to special circumstance.
Q: The producing nitrogen/oxygen is gaseous state or liquid state?
Our nitrogen/oxygen equipment use PSA air separation technology under normal temperature,with no-low temperature operation,the temperature of nitrogen/oxygen product is close to ambient temperature.
Q: How long is the nitrogen/oxygen equipment service life?
Generally speaking,industrial equipment service life is depend on daily maintenance. under normal maintenance,our equipment can well running for more than 10 years.
Q: How is the maintenance time of oxygen equipment?
For Air purification module: the primary filters need to replace after 4000h normal operation; precision,extra-precision filters need to replace after 8000h,12000h normal operation; valve seal seal for 16000h;other filters depend on actual operation.
Our HYT team will design and customized relate technical project and provide the suitable selection and quotation for you in time.