25 л Пена/сухой порошок/вода углеродистая сталь автоматические системы пожаротушения для горного оборудования

Сохранить в закладки 1601298710413:


Цена:71 175,76-79 211,73 ₽*

Количество:

  • В избранное

Описание и отзывы

Характеристики



Product Description




Product features
1.Fast detection and high efficiency
2.Rechargeable
3.Adapted to harsh environments
4.Lightweight, not burdensome to equipment

5.Simple installation and maintenance
6.Suitable for heavy duty mining machine
7.Comtrol panel shows real-time temperature
8.Available in many agents: foam, novec1230, water mist, dry powder, FM200,etc




Principles of systems



1.Temperature Sensor Model/Solenoid Valve
Step1:
Detection Tube ruptures to hole when temperature reach 140℃, and release pressure through the hole.(Or pushing the manual button of detection tube,pressure releasing from themanual button.)
Step2:
The resulting drop in pressure causes the head valve to be activated. At the same time the fire arlar was activated.
Valve was opened and agent was discharged through the discharge tubing to the nozzles.
Step3:
Agent covering the area and suppressing the fire quickly and thoroughly.
This system is totally automatic and is totally independent of electricity.



Product drawing




Inside the Pneumatic valve there is a piston, it divide the valve cavity to 2 parts. The upper cavity connect to detection tube, the lower cavity connect to bottle. The pressure of the 2 side of the piston is same. During the fire, Once the detection tube detected fire and ruptured one hole to release the pressure. Then the pressure of 2 side of the piston happen different, the piston was moved to up, and the outlet port of the valve was opened, and agent was discharged from the pipe and nozzles. At the same time, the pressure switch send final to fire alarm, the fire alarm was activated. On the control panel, there is a manual button and test button, reset button. In emergency Pushing the manual button can activate the fire system too.


Diagram of R107 Systems for Temperature Sensor Model.


Single Bottle
Temperature Sensor

Main Components


2~3 Bottle
Temperature Sensor
Main Component



2.Detection Tube Model/Pneumatic Valve
Step1:
Detection Tube ruptures to hole when temperature reach 140℃, and release pressure through the hole.(Or pushing the manual button of detection tube,pressure releasing from themanual button.)
Step2:
The resulting drop in pressure causes the head valve to be activated. At the same time the fire arlar was activated.
Valve was opened and agent was discharged through the discharge tubing to the nozzles.
Step3:
Agent covering the area and suppressing the fire quickly and thoroughly.
This system is totally automatic and is totally independent of electricity.



Product drawing




Inside the Pneumatic valve there is a piston, it divide the valve cavity to 2 parts. The upper cavity connect to detection tube, the lower cavity connect to bottle. The pressure of the 2 side of the piston is same. During the fire, Once the detection tube detected fire and ruptured one hole to release the pressure. Then the pressure of 2 side of the piston happen different, the piston was moved to up, and the outlet port of the valve was opened, and agent was discharged from the pipe and nozzles. At the same time, the pressure switch send final to fire alarm, the fire alarm was activated. On the control panel, there is a manual button and test button, reset button. In emergency Pushing the manual button can activate the fire system too.


Diagram of R107 Systems for Detection Tube Model.


Single Bottle
Fire Detection Tube
Main Components


2~3 Bottle
Fire Detection Tube
Main Components


Specification


PRI-SAFETY Mining Machine Fire Suppression Systems

KFS-02
Brand Name
PRI-SAFETY
Capacity
6L, 9L, 12L, 18L, 20L, 25L, 50L—FOAM (18L for 4CBM Engine Room) 
6kg, 9kg, 12kg, 18kg, 25kg, 50kg---Dry Powder (9kg for 4CBM Engine Room)
Agent
Foam / Dry Powder
Working Pressure
14Bar
Testing Pressure
27Bar
Cylinder Material
Steel red painting Or Stainless Steel 304
Certificate
UN ECE R107 , CE
System Activated Temperature
140℃ or Customized Temperature


Note:
For Vehicle Engine Room, we can choose different fire agents, such as Water, AFFF3% Foam, FM200, or Dry Powder agents.
The different systems are with different discharge tube and nozzles.




Certifications


UNECE R107 and CE Approved



Application










Company Profile




PRI-SAFETY specializes in the manufacture and exportation of Automatic Fire Systems, Throw Type Fire Extinguishers, CAFS Compressed Air Foam Fire Systems, Fire Extinguishers, Fire Hose Reels, Fire Hoses, Fire Cabinets, Valves, Pressure Gauges, Couplings, Smoke Alarms, Fire Blanket and other fire equipment, etc. We focus on providing one-stop fire-fighting products and professional service.

We have attained ISO9001:2000, CE, EN3, EN1869 and EN694 certifications. Almost all products that we provide are manufactured and tested according to the international standard. We also supply OEM service, we can design and produce the products as client's special request.

PRI-SAFETY also has very good after-sales service, we have one professional,high efficient and warmly sales team. We promise that all feedbacks from clients would be replied within 8 hours during working days. We always try our best to provide better service to meet our clients' demands.

Our company rule is saving time and cost for clients, taking good profit and well development for clients. We supply well growing space and training for each staff, help staffs to achieve their dreams. Then clients and staffs push our company development.


Exhibition




Packing & Delivery


Strict Inspection
Each Products will be tested and inspected before packing to make sure each products are in correct situation and good quality.

High Quality Wooden Box
Export with high quallity wooden box.



FAQ


Q1. May I get a sample before placing an order?
A1. Yes, no problem.


Q2. Are your company PRI-SAFETY a manufacturer or trading company?
A2. We are a manufacturer.


Q3. Can you print our logo on products?
A3. Yes, no problem. We also support OEM.


Q4. How long does it take to delivery?
A4. In 30-45 days after receipt of 30% deposit.


Q5. What's your MOQ?
A5. Fire extinguisher is class2.2 Dangerous Goods, it should be loaded with full container.
But if you have another goods shipping together or you need empty type, our MOQ is 100 sets.

Q6.What's your Payment Term?
A6.We support T/T,L/C,Credit Card,Western Union etc.