Зонд влажности почвы NPK PH станция мониторинга LoRa 4G беспроводной измеритель надежный коллектор умные сельскохозяйственные датчики
30 707,10 ₽
Сохранить в закладки 1601341364453:
TEREN multi function 3.2'' color TFT LCD display unit with transmitter for Temperature/humidity/Diff.Pressure measuring Applications& Features l Apply for flush mount, measure and display environment temperature, humidity and diff. pressure l 316L front panel, PMMA window, flat surface, no dust stays, good for all detergents, sanitizers and bactericides l Parallel or alternatively display input channels 1 to 3 l Large high light 3.2” color TFT LCD display l Multiple inputs and outputs for different applications l High accuracy sensor, 100% field changeable l Optional 3 analog 4~20mA/0~10V inputs signals l Optional 3 analog 0~10V outputs signals l Optional RS485/Modbus RTU and key functions l Compatible to any DDC/PLC/SCADA or other data collect and control systems l Very high performance/price ratio: replace the single T/RH/DP instruments, provide value added multi-function combination of local measurement, display and networking Specifications Display Display: high light 3.2” color TFT LCD, resolution 320×240 Display panel material: PMMA Resolution: ±0.1 engineering unit Channels: 1~3 channels, parallel (simultaneously) or single line (alternate) display Engineering unit: 3 preset units, °C/°F, %RH and Pa Update time: <1s Housing Front panel material: 316L stainless steel, 1.5mm thick Back housing parts: fire retardant ABS+PC(UL94V-0) Protection: front panel IP65 (built-in temp. & humidity sensor cap IP54) Weight: MINI: about 380g; Horizontal: about 450g; Vertical: about 650g Technical Specifications Power Supply: 16~28VAC/16~35VDC Consumption: 0.5VA | ||||||||
Analog inputs: max. 3×(4~20mA/0~10V); over voltage and reverse polarity protection; accuracy<0.1%FS; RL<250Ω(4~20mA) or>100KΩ(0~10V); range: default 0~50°C/0~100%RH/0~60Pa, available range -50~100°C/0~100%RH/-100~100Pa Analog outputs: max. 3×(0~10V); over voltage and reverse polarity protection; accuracy as low as 0.2%FS; RL>2KΩ; range: same as analog inputs Keys: set/reset alarm, DP re-zero, calibration, set display mode, etc. Communication: 1 USB for parameter checking and setting, 1 RS485/Modbus RTU, R/W enable, 9600 baud rate Terminals: max 1.5mm2 Work Environment: 0~50°C, 0~95%RH (no cond.) Storage Environment: -10~70°C Process connection: Built-in T/RH sensor: a waterproof, air breathable filter and sensing cap on front panel. Built-in diff. pressure sensor: 2 conical nozzles, Ø 5 mm tube connection on back, or 1 pressure sampling screw on front panel. Approval: CE | ||||||||
Новинки товаров от производителей по оптовым ценам