Сохранить в закладки 1601364926468:
Part Number | 98011301 |
Model | S200-8P4S |
Description | S200-8P4S (8*10/100/1000BASE-T ports, 4*GE SFP ports, PoE+, AC power) |
Wide [mm] | 300.0 mm | ||||
Depth [mm] | 220.0 mm | ||||
Height [mm] | 43.6 mm | ||||
Chassis height [U] | 1 | ||||
Weight with packaging [kg(lb)] | 3.17 kg (7 lb) | ||||
Weight without packaging [kg(lb)] | 2.25 kg (4.96 lb) | ||||
Typical power consumption [W] | 28.4 | ||||
Maximum power consumption [W] | - Not providing the PoE function: 38.6 W - 100% PoE loads: 162.6 W (PoE: 124 W) | ||||
Typical heat dissipation [BTU/hour] | 96.9 | ||||
Maximum heat dissipation [BTU/hour] | - Not providing the PoE function: 131.71 - 100% PoE loads: 554.81 | ||||
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment | ||||
Power supply mode | AC built-in | ||||
Rated input voltage [V] | AC input: 100 V AC to 240 V AC, 50/60 Hz | ||||
Input voltage range [V] | AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz | ||||
Maximum input current [A] | 3 A | ||||
Number of card slots | 0 | ||||
Number of power slots | 0 | ||||
Memory | 512 MB | ||||
Flash memory | 512 MB | ||||
Redundant power supply | Not supported | ||||
Types of fans | Built-in | ||||
Noise at normal temperature (acoustic pressure) [dB(A)] | 30.5 | ||||
Noise at normal temperature (acoustic power) [dB(A)] | 42.2 | ||||
Airflow direction | Air intake from left and front, air exhaustion from right | ||||
Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) (0 m to 1800 m altitude, non-industrial optical modules) -5°C to +55°C (23°F to 131°F) (0 m to 1800 m altitude, industrial optical modules with transmission distances less than or equal to 10 km) | ||||
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) | ||||
Restriction on the operating temperature variation rate | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0°C (32°F). The operating temperature ranges from -5°C to +45°C (23°F to 113°F) when optical modules with transmission distances greater than or equal to 70 km are used. | ||||
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing | ||||
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) | ||||
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) | ||||
MTBF [year] | 66.56 | ||||
MTTR [hour] | 2 | ||||
Availability | >0.99999 | ||||
Maximum number of physical ports on the entire device | 12 | ||||
Maximum number of 100GE ports | 0 | ||||
Maximum number of 40GE ports | 0 | ||||
Maximum number of 25GE ports | 0 | ||||
Maximum number of 10GE ports | 0 | ||||
Maximum number of GE ports | 12 | ||||
Maximum number of FE ports | 12 | ||||
1000M electrical interface | 8 | ||||
1000M optical interface | 4 | ||||
USB | Not supported | ||||
Console port | RJ45 | ||||
Eth Management port | Not supported | ||||
Service port surge protection | Common mode: ±7 kV | ||||
Power supply surge protection | ±6 kV in differential mode, ±6 kV in common mode | ||||
RPS input | Not supported | ||||
PoE | Supported | ||||
PoE power supply | Supported |