Features


• Pipettes cover a volume range from 0.1μL to 10mL


• Ergonomic design provides excellent operating experience


• Large display window allows for easy volume identification


• Easy calibration and maintenance


• Each PIPE-M supplied with an individual calibration certificate according to ISO8655


• Online calibration is available 


 


• 8 and 12 channel pipettes are appropriate for 96 well plates


• Dispensing head rotates for effortless pipetting convenience


• Individual piston and tip cone assemblies allowing easy repair and maintenance


• Compound material-made tip cone secures high sealing performance


• Compatible with most universal tip brands


• Online calibration is available


 


 





Specifications


 













































































































































































































































































































































































































































































PIPE-M Single-channel Adjustable Volume Pipettes



Volume Range



Increment



Test Volume



Error limits in accordance with ISO8655-2



(Accuracy error)



(Precision error)



%



μL



%



μL



0.1-2.5μL



0.05μL



2.5μL



2.50%



0.0625



2.00%



0.05



1.25μL



3.00%



0.0375



3.00%



0.0375



0.25μL



12.00%



0.03



6.00%



0.015



0.5-10μL



0.1μL



10μL



1.00%



0.1



0.80%



0.08



5μL



1.50%



0.075



1.50%



0.075



1μL



2.50%



0.025



1.50%



0.015



2-20μL



0.5μL



20μL



0.90%



0.18



0.40%



0.08



10μL



1.20%



0.12



1.00%



0.1



2μL



3.00%



0.06



2.00%



0.04



5-50μL



0.5μL



50μL



0.60%



0.3



0.30%



0.15



25μL



0.90%



0.225



0.60%



0.15



5μL



2.00%



0.1



2.00%



0.1



10-100μL



1μL



100μL



0.80%



0.8



0.15%



0.15



50μL



1.00%



0.5



0.40%



0.2



10μL



3.00%



0.3



1.50%



0.15



20-200μL



1μL



200μL



0.60%



1.2



0.15%



0.3



100μL



0.80%



0.8



0.30%



0.3



20μL



3.00%



0.6



1.00%



0.2



50-200μL



1μL



200μL



0.60%



1.2



0.15%



0.3



100μL



0.80%



0.8



0.30%



0.3



50μL



1.00%



0.5



0.40%



0.2



100-1000μL



5μL



1000μL



0.60%



6



0.20%



2



500μL



0.70%



3.5



0.25%



1.25



100μL



2.00%



2



0.70%



0.7



200-1000μL



5μL



1000μL



0.60%



6



0.20%



2



500μL



0.70%



3.5



0.25%



1.25



200μL



0.90%



1.8



0.30%



0.6



1000-5000μL



50μL



5000μL



0.50%



25



0.15%



7.5



2500μL



0.60%



15



0.30%



7.5



1000μL



0.70%



7



0.30%



3



2-10mL



0.1mL



10mL



0.60%



60



0.20%



20



5mL



1.20%



60



0.30%



15



2mL



3.00%



60



0.60%



12



Specifications are used as guidelines and the user calibration should refer to the industrial standard ISO 8655



 


 



PIPE-M8 8-channel Adjustable Volume Pipettes



Volume Range



Increment



Test Volume



Error limits in accordance with


ISO8655-2



(Accuracy error)



(Precision error)



%



μL



%



μL



0.5-10μL



0.1μL



10μL



1.50%



0.15



1.50%



0.15



5μL



2.50%



0.125



2.50%



0.125



1μL



4.00%



0.04



4.00%



0.04



5-50μL



0.5μL



50μL



1.00%



0.5



0.50%



0.25



25μL



1.50%



0.375



1.00%



0.25



5μL



3.00%



0.15



2.00%



0.1



50-300μL



5μL



300μL



0.70%



2.1



0.25%



0.75



150μL



1.00%



1.5



0.50%



0.75



50μL



1.50%



0.75



0.80%



0.4



PIPE-M12 12-channel Adjustable Volume Pipettes



Volume Range



Increment



Test Volume



Error limits in accordance with


ISO8655-2



(Accuracy error)



(Precision error)



%



μL



%



μL



0.5-10μL



0.1μL



10μL



1.50%



0.15



1.50%



0.15



5μL



2.50%



0.125



2.50%



0.125



1μL



4.00%



0.04



4.00%



0.04



5-50μL



0.5μL



50μL



1.00%



0.5



0.50%



0.25



25μL



1.50%



0.375



1.00%



0.25



5μL



3.00%



0.15



2.00%



0.1



50-300μL



5μL



300μL



0.70%



2.1



0.25%



0.75



150μL



1.00%



1.5



0.50%



0.75



50μL



1.50%



0.75



0.80%



0.4




 

2.png 

 

 




Related Products


1.jpg  4.jpg   3.jpg


Electronic Pipette Controller          Manual Volume Pipettes                    Bottle-Top Dispenser





Packaging & Shipping


packaging.jpg 





Certificates


Certificates.jpg 





About us


-.jpg-01.jpg


-footer bar01




Похожие товары

Новые поступления

Новинки товаров от производителей по оптовым ценам