Model LK-DD series Evaporator can be used as cooling device in varies cold storages, like simple cold storage or combined cold storage. There are type LK-DDH,LK-DDM and LK-DDL unit coolers, which are ideal for different refrigerating purposes. It's compact in structure, light in weight, no space occupation,high in efficiency to balance and lower refrigerating temperature.

Application:

Working with compressor condensing units of different refrigerating capacity,LK-DD series unit cooler is applied to different purposes of cold storage.LK-DDH type can be used at about 0°C for saving eggs and vegetables;LK-DDM type can be used at-18°C for saving meats and fishes; LK-DDL type can be used at-25°C or below for quick-freezing to preserve fresh meat and live fish.

Feature:

1. The housing is in plastic-sprayed coat or rolled from aluminum plate,best corrosion protection, beautiful in shape. 

2. Original coil arrangement to reduce the side resistance. The aluminum fins are fasten ed to the steel tubes by hydraulic expanding way, which is effective to reduce thermal contact resistance and improve thermal transfer. 

3. After pressure test, wash with trichloroethylene to clean the oily dirt,moisture, oxide and other impurities inside. As such, no blocking trouble after filling with refrigerant in use. 

4.Special fan motor, which is low in power consumption, large in air volume, low in noise, send far in air throw, guarantees good performance in humidity and low temperature. 

5.Equipped with U-shaped electro-thermal tube that's good in insulation inside the coil,rational gap arrangement and power capacity to achieve desirable defrosting performance. 

6.Groove-type channel clip, easy to install. 

7.Filled with nitrogen before leaving factory.

1.png

Main Technical Parameter of LK-DDM Series Unit Cooler:

ModelNorminal Cooling Capacity kw,troom=-18℃,Δt=(troom-t0)=7℃Cooling areaPinch  FAN MOTOR     HEATING TUBERemark
 QTYDIA φ air volumerange  motor power voltagecoilwater panvoltage
 m∧2 mmpcs mm m∧3 m w vkwkwvCan be used for R134a R404A AND R502
LK-DDM71.4 7 6      13001*2000 61*130 2200.90.6220
LK-DDM12 2.6 12 23002*2000 62*1300.90.6
LK-DDM15 3.0 15 300 2*2000 10 2*130 380  0.90.6
LK-DDM22 4.0 22 350 2*2500 10 2*135 1.20.6
LK-DDM30 5.0 30 400 2*3500 12 2*190 2.50.8
LK-DDM4084024002*3500122*1902.80.8
LK-DDM60126024502*5000172*3704.51
LK-DDM8015.98025002*6000173*150061
LK-DDM1002010035003*6000173*55071.2
LK-DDM1202412035003*6000173*5507.71.4
LK-DDM1402814045004*6000174*55091.5
LK-DDM16032.116045004*6000174*55010.52
LK-DDM200 37.4 200 600 2*10000 20 2*1500 12.52.2
LK-DDM250 46.8 250 600 3*10000 22 3*1100 142.2
LK-DDM31056.231036003*10000223*1100152.6
LK-DDM36065.236037003*14000223*2200283
LK-DDM44079.644037003*14000223*220018.83.2

As for the cooling capacity under condition of the refrigeration is R22,troom=-18℃,At=7℃,we need to multiply the correction factor for the cooling capacity with refrigerant R134,QoR134a=QoR22*f.

 

Main Technical Parameter of LK-DDL Series Unit Cooler:

ModelNorminal Cooling Capacity kw,troom=-18℃,Δt=(troom-t0)=7℃Cooling areaPinch  FAN MOTOR     HEATING TUBERemark
 QTYDIA φ air volumerange  motor power voltagecoilwater panvoltage
 m∧2 mmpcs mm m∧3 m w vkwkwvCan be used for R134a R404A AND R502
LK-DDL81.28 9   13001*200081*85 2200.80.8220
LK-DDL12 1.9 1223002*200082*850.90.9
LK-DDL15 2.3 153502*2500 10 2*135 380  1.81
LK-DDL20  4.020400 2*3500 122*190 2.41
LK-DDL305.130400 2*3500 12 2*190 3.51
LK-DDL407.84024502*5000172*5504.81.2
LK-DDL559.85525002*6000172*5506.81.2
LK-DDL7012.87035003*6000173*5507.81.5
LK-DDL8015.78035003*6000173*5508.52
LK-DDL10018.810045004*6000174*550102.2
LK-DDL11521.611545004*6000174*550122.2
LK-DDL14023.814026002*10000222*1100152.4
LK-DDL170 29170600 3*10000 223*1100 162.4
LK-DDL21035.9210 600 3*10000 22 3*1100 193
LK-DDL25042.725037003*14000223*2200283
LK-DDL30050.330037003*14000223*220028.83.2

As for the cooling capacity under condition of the refrigeration is R22,troom=0℃,At=7℃,we need to multiply the correction factor for the cooling capacity with refrigerant R134,QoR134a=QoR22*f. 

 

Main Technical Parameter of LK-DDH Series Unit Cooler:

ModelNorminal Cooling Capacity kw,troom=-18℃,Δt=(troom-t0)=7℃Cooling areaPinch  FAN MOTOR     HEATING TUBERemark
 QTYDIA φ air volumerange  motor power voltagecoilwater panvoltage
 m∧2 mmpcs mm m∧3 m w vkwkwvCan be used for R134a R404A AND R502
LK-DDH102.210 4.5     13001*200081*130 2200.50.5220
LK-DDH15 3.315 23002*200082*1300.80.8
LK-DDH20 4.220 300 2*2000 102*135380  0.90.6
LK-DDH25 5.225 350 2*2500 102*135 1.20.6
LK-DDH40 8.140400 2*3500 12 2*190 1.40.6
LK-DDH5511.25524002*3500122*1901.80.8
LK-DDH8016.28024502*5000172*5502.80.8
LK-DDH10521.610525002*6000172*55030.8
LK-DDH12525.512535003*6000173*5504.50.8
LK-DDH16034.216035003*6000173*5505.50.8
LK-DDH18538.718545004*6000174*55061.2
LK-DDH21042.821045004*6000174*5507.51.4
LK-DDH26052.6260600 2*10000 222*1100 91.5
LK-DDH330 67.7 30600 3*10000 223*1100 111.5
LK-DDH41082.641036003*10000223*110012.52
LK-DDH47095.647037003*14000223*2200152.5
LK-DDH58011758037003*14000223*220016.22.7

we need to multiply the correction factor for the cooling capacity with refrigerant R134,QoR134a=QoR22*f.  