Сохранить в закладки 60664112889:
Mesh Nebulizer
Pulse Oximeter
Fetal Doppler
Dynamic 3 channel ECG Systems
Model No.:TLC9803
Recorder Features
* With advanced design and technology, the recorder can work stably,dependable and durable
* Be provided with the capability of anti-jamming and shock-pro.
* Small volume with OLED screen. The resolution is 160*128.
* Be provided with functions of waveform preview, record review and event marking.
*Accurate record of the start time of the data sampled owing to the real time clock of itself.
*Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data.
*The maximum capability can be 2GB, so the original data can be saved perfectly by no compression.
*The average review time of single case can be less than 40 seconds by using interface of USB 2.0.
*Record waveform details inextenso by the design of high precision and sampling frequency.
*Record the state of pacemaker exactly by higher sampling frequency.
The features of software
*Quick and accurate analysis system.
*With 3 leads synchro analysis, QRS search can be more exactly.
* There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
*Optional main channel.
* Agile and exact "Atrial Fibrillation" analysis.
*The function of pacing analysis could analyse all pacemakers.
* Many pacine modules have been added.
* Any period of single lead or 3-leads ECG can be reviewed at any time with the function of fast waveform review and analysis.
* The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG.
* Print report expediently.
* Perfect function of case management.
* With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally.
*"Sleep breath pause syndrome analysis", the physician could print sleep asphyxia analysis report and diagnose.
*"HRT" analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately.
*15."T Wave Alternation" analysis is a important index on judging and preventing arrhythmia.
Accessories:
3-lead ECG lead wires *1
ECG electrode *1
USB data line*1
Disk*1
Bag*1
User manual*1
Softdog*1